使用乳酸林格氏液或 6% tetrastarch 130/0.4 对猫出血/过度复苏模型进行凝血酶原和活化部分凝血活酶时间、血栓弹力图、血细胞比容和血小板计数的研究。

IF 1.1 3区 农林科学 Q3 VETERINARY SCIENCES Journal of veterinary emergency and critical care Pub Date : 2024-06-14 DOI:10.1111/vec.13376
Gareth E. Zeiler BVSc(Hons), MMedVet(Anaesth), PhD, DECVECC, DECVAA, DACVAA, Brighton T. Dzikiti BVSc, MSc, PhD, Eva Rioja BVSc, DVM, PhD, DACVAA, Peter Kamerman BSc, PhD, Roxanne K. Buck BVSc, MMedVet(Anaesth), DECVAA, Friederike Pohlin BVSc, PhD, Andrea Fuller BSc, PhD
{"title":"使用乳酸林格氏液或 6% tetrastarch 130/0.4 对猫出血/过度复苏模型进行凝血酶原和活化部分凝血活酶时间、血栓弹力图、血细胞比容和血小板计数的研究。","authors":"Gareth E. Zeiler BVSc(Hons), MMedVet(Anaesth), PhD, DECVECC, DECVAA, DACVAA,&nbsp;Brighton T. Dzikiti BVSc, MSc, PhD,&nbsp;Eva Rioja BVSc, DVM, PhD, DACVAA,&nbsp;Peter Kamerman BSc, PhD,&nbsp;Roxanne K. Buck BVSc, MMedVet(Anaesth), DECVAA,&nbsp;Friederike Pohlin BVSc, PhD,&nbsp;Andrea Fuller BSc, PhD","doi":"10.1111/vec.13376","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>To describe and compare prothrombin time (PT), activated partial thromboplastin time (aPTT), thromboelastography (TEG), HCT, and platelet count measurements in a hemorrhage/over-resuscitation model.</p>\n </section>\n \n <section>\n \n <h3> Design</h3>\n \n <p>Randomized crossover study.</p>\n </section>\n \n <section>\n \n <h3> Setting</h3>\n \n <p>University teaching hospital.</p>\n </section>\n \n <section>\n \n <h3> Animals</h3>\n \n <p>Six cats.</p>\n </section>\n \n <section>\n \n <h3> Interventions</h3>\n \n <p>Anesthetized cats underwent 3 treatments at 2-month intervals. The treatments were as follows: NHR—no controlled hemorrhage and sham resuscitation; LRS—controlled hemorrhage and lactated Ringer's solution (LRS) for resuscitation; and Voluven—controlled hemorrhage and 6% tetrastarch 130/0.4 for resuscitation. The LRS and Voluven were administered at 60 and 20 mL/kg/h, respectively, for 120 minutes. Blood samples were drawn for PT, aPTT, TEG, HCT, and platelet count measurements at a healthy check (T − 7d), after controlled hemorrhage (T0), at 60 and 120 minutes of resuscitation (T60 and T120), and at 24 hours after completion of resuscitation (T24h). Data were analyzed using a general linear mixed model approach (significance was <i>P</i> &lt; 0.05).</p>\n </section>\n \n <section>\n \n <h3> Measurements and Main Results</h3>\n \n <p>Total median blood loss (controlled hemorrhage and blood sampling from T0 to T120) at T120 was 11.4, 31.0, and 30.8 mL/kg for NHR, LRS, and Voluven, respectively. PT and aPTT during LRS and Voluven were prolonged at T60 and T120 compared to NHR (<i>P</i> &lt; 0.001). On TEG, the reaction time, kinetic time, and alpha-angle were within reference intervals for cats at all time points in all treatments, while maximum amplitude was less than the reference interval (40 mm) at T0, T60, and T120 during Voluven and at T60 and T120 during LRS compared to NHR (both <i>P</i> &lt; 0.001). The HCT and platelet count were significantly lower at T60 and T120 during LRS and Voluven compared to NHR (<i>P</i> &lt; 0.001).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Hypocoagulopathy was observed during hemorrhage and liberal fluid resuscitation. Prolongation of PT and aPPT and decreased clot strength may have been caused by hemodilution and platelet loss.</p>\n </section>\n </div>","PeriodicalId":17603,"journal":{"name":"Journal of veterinary emergency and critical care","volume":"34 4","pages":"356-367"},"PeriodicalIF":1.1000,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/vec.13376","citationCount":"0","resultStr":"{\"title\":\"Prothrombin and activated partial thromboplastin times, thromboelastography, hematocrit, and platelet count in a feline hemorrhage/over-resuscitation model using lactated Ringer's solution or 6% tetrastarch 130/0.4\",\"authors\":\"Gareth E. Zeiler BVSc(Hons), MMedVet(Anaesth), PhD, DECVECC, DECVAA, DACVAA,&nbsp;Brighton T. Dzikiti BVSc, MSc, PhD,&nbsp;Eva Rioja BVSc, DVM, PhD, DACVAA,&nbsp;Peter Kamerman BSc, PhD,&nbsp;Roxanne K. Buck BVSc, MMedVet(Anaesth), DECVAA,&nbsp;Friederike Pohlin BVSc, PhD,&nbsp;Andrea Fuller BSc, PhD\",\"doi\":\"10.1111/vec.13376\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>To describe and compare prothrombin time (PT), activated partial thromboplastin time (aPTT), thromboelastography (TEG), HCT, and platelet count measurements in a hemorrhage/over-resuscitation model.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Design</h3>\\n \\n <p>Randomized crossover study.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Setting</h3>\\n \\n <p>University teaching hospital.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Animals</h3>\\n \\n <p>Six cats.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Interventions</h3>\\n \\n <p>Anesthetized cats underwent 3 treatments at 2-month intervals. The treatments were as follows: NHR—no controlled hemorrhage and sham resuscitation; LRS—controlled hemorrhage and lactated Ringer's solution (LRS) for resuscitation; and Voluven—controlled hemorrhage and 6% tetrastarch 130/0.4 for resuscitation. The LRS and Voluven were administered at 60 and 20 mL/kg/h, respectively, for 120 minutes. Blood samples were drawn for PT, aPTT, TEG, HCT, and platelet count measurements at a healthy check (T − 7d), after controlled hemorrhage (T0), at 60 and 120 minutes of resuscitation (T60 and T120), and at 24 hours after completion of resuscitation (T24h). Data were analyzed using a general linear mixed model approach (significance was <i>P</i> &lt; 0.05).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Measurements and Main Results</h3>\\n \\n <p>Total median blood loss (controlled hemorrhage and blood sampling from T0 to T120) at T120 was 11.4, 31.0, and 30.8 mL/kg for NHR, LRS, and Voluven, respectively. PT and aPTT during LRS and Voluven were prolonged at T60 and T120 compared to NHR (<i>P</i> &lt; 0.001). On TEG, the reaction time, kinetic time, and alpha-angle were within reference intervals for cats at all time points in all treatments, while maximum amplitude was less than the reference interval (40 mm) at T0, T60, and T120 during Voluven and at T60 and T120 during LRS compared to NHR (both <i>P</i> &lt; 0.001). The HCT and platelet count were significantly lower at T60 and T120 during LRS and Voluven compared to NHR (<i>P</i> &lt; 0.001).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Hypocoagulopathy was observed during hemorrhage and liberal fluid resuscitation. Prolongation of PT and aPPT and decreased clot strength may have been caused by hemodilution and platelet loss.</p>\\n </section>\\n </div>\",\"PeriodicalId\":17603,\"journal\":{\"name\":\"Journal of veterinary emergency and critical care\",\"volume\":\"34 4\",\"pages\":\"356-367\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/vec.13376\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of veterinary emergency and critical care\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/vec.13376\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of veterinary emergency and critical care","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/vec.13376","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的描述并比较出血/过度复苏模型中凝血酶原时间(PT)、活化部分凝血活酶时间(aPTT)、血栓弹力图(TEG)、HCT 和血小板计数的测量结果:随机交叉研究:动物:六只猫六只猫:干预措施:麻醉猫接受 3 次治疗,每次间隔 2 个月。治疗方法如下NHR-无控制出血和假复苏;LRS-控制出血和乳酸林格氏液(LRS)复苏;Voluven-控制出血和 6% 四淀粉 130/0.4 复苏。LRS和Voluven的给药速度分别为60毫升/千克/小时和20毫升/千克/小时,持续120分钟。在健康检查(T - 7d)、控制出血后(T0)、复苏 60 分钟和 120 分钟(T60 和 T120)以及复苏结束后 24 小时(T24h)抽取血样进行 PT、aPTT、TEG、HCT 和血小板计数测量。数据采用一般线性混合模型方法进行分析(显著性为 P 测量和主要结果:T120时,NHR、LRS和Voluven的总失血中位数(T0至T120的控制性出血和采血)分别为11.4、31.0和30.8 mL/kg。与 NHR 相比,LRS 和 Voluven 在 T60 和 T120 时的 PT 和 aPTT 延长(P 结论):在大出血和大量液体复苏期间可观察到低凝血功能。PT 和 aPPT 的延长以及凝血强度的降低可能是由血液稀释和血小板丢失引起的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Prothrombin and activated partial thromboplastin times, thromboelastography, hematocrit, and platelet count in a feline hemorrhage/over-resuscitation model using lactated Ringer's solution or 6% tetrastarch 130/0.4

Objective

To describe and compare prothrombin time (PT), activated partial thromboplastin time (aPTT), thromboelastography (TEG), HCT, and platelet count measurements in a hemorrhage/over-resuscitation model.

Design

Randomized crossover study.

Setting

University teaching hospital.

Animals

Six cats.

Interventions

Anesthetized cats underwent 3 treatments at 2-month intervals. The treatments were as follows: NHR—no controlled hemorrhage and sham resuscitation; LRS—controlled hemorrhage and lactated Ringer's solution (LRS) for resuscitation; and Voluven—controlled hemorrhage and 6% tetrastarch 130/0.4 for resuscitation. The LRS and Voluven were administered at 60 and 20 mL/kg/h, respectively, for 120 minutes. Blood samples were drawn for PT, aPTT, TEG, HCT, and platelet count measurements at a healthy check (T − 7d), after controlled hemorrhage (T0), at 60 and 120 minutes of resuscitation (T60 and T120), and at 24 hours after completion of resuscitation (T24h). Data were analyzed using a general linear mixed model approach (significance was P < 0.05).

Measurements and Main Results

Total median blood loss (controlled hemorrhage and blood sampling from T0 to T120) at T120 was 11.4, 31.0, and 30.8 mL/kg for NHR, LRS, and Voluven, respectively. PT and aPTT during LRS and Voluven were prolonged at T60 and T120 compared to NHR (P < 0.001). On TEG, the reaction time, kinetic time, and alpha-angle were within reference intervals for cats at all time points in all treatments, while maximum amplitude was less than the reference interval (40 mm) at T0, T60, and T120 during Voluven and at T60 and T120 during LRS compared to NHR (both P < 0.001). The HCT and platelet count were significantly lower at T60 and T120 during LRS and Voluven compared to NHR (P < 0.001).

Conclusions

Hypocoagulopathy was observed during hemorrhage and liberal fluid resuscitation. Prolongation of PT and aPPT and decreased clot strength may have been caused by hemodilution and platelet loss.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.50
自引率
15.40%
发文量
121
审稿时长
18-36 weeks
期刊介绍: The Journal of Veterinary Emergency and Critical Care’s primary aim is to advance the international clinical standard of care for emergency/critical care patients of all species. The journal’s content is relevant to specialist and non-specialist veterinarians practicing emergency/critical care medicine. The journal achieves it aims by publishing descriptions of unique presentation or management; retrospective and prospective evaluations of prognosis, novel diagnosis, or therapy; translational basic science studies with clinical relevance; in depth reviews of pertinent topics; topical news and letters; and regular themed issues. The journal is the official publication of the Veterinary Emergency and Critical Care Society, the American College of Veterinary Emergency and Critical Care, the European Veterinary Emergency and Critical Care Society, and the European College of Veterinary Emergency and Critical Care. It is a bimonthly publication with international impact and adheres to currently accepted ethical standards.
期刊最新文献
Fabio Viganó Jennifer J. Devey Issue Information - Prelim AUTHOR INDEX Abstracts from the International Veterinary Emergency and Critical Care Symposium and the European Veterinary Emergency and Critical Care Annual Congress 2024
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1