Julian Bickel, Hilke Jungen, Alexander Müller, Anne Szewczyk, Benjamin Ondruschka, Stefanie Iwersen-Bergmann
{"title":"尸体血液样本中 35 种药物的毒理学分析,重点是抗高血压和抗心律失常药物","authors":"Julian Bickel, Hilke Jungen, Alexander Müller, Anne Szewczyk, Benjamin Ondruschka, Stefanie Iwersen-Bergmann","doi":"10.1016/j.jchromb.2024.124196","DOIUrl":null,"url":null,"abstract":"<div><p>Antiarrhythmic and antihypertensive drugs are frequently encountered in post mortem analysis, and the question may arise as to whether they were administered in therapeutic doses, and if they were taken in accidental, intentional, or suicidal overdose scenarios. Therefore, a novel analytical method was developed and validated for the quantification of 35 drugs with toxicological relevance, including antihypertensive and antiarrhythmic drugs (ajmaline, amlodipine, amiodarone, atenolol, bisoprolol, carvedilol, clonidine, desethylamiodarone, diltiazem, donepezil, doxazosin, dronedarone, esmolol, flecainide, lercanidipine, lidocaine, metoprolol, nebivolol, nimodipine, pindolol, prajmaline, propafenone, propranolol, sotalol, urapidil, and verapamil), as well as other medications commonly found in combination (sildenafil, tadalafil, atorvastatin, clopidogrel, dapoxetine, memantine, pentoxifylline, rivastigmine, and ivabradine). The method enables simultaneous identification and quantification in blood samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS).</p><p>Validation exhibited excellent linearity across the concentration range for all analytes. Precision and accuracy were within acceptable limits, with bias and relative standard deviation (RSD) values consistently below 9 % and 10 %, respectively. Selectivity and specificity assessments confirmed the absence of any interference from contaminants or co-extracted drugs. The method demonstrated very high sensitivity, with limits of detection (LOD) as low as 0.01 ng/ml and limits of quantification (LOQ) as low as 0.04 ng/ml. Extraction recovery exceeded 57.5 % for all analytes except atenolol, and matrix effects were <17 % for all analytes except pindolol. Processed sample stability evaluations revealed consistent results with acceptable deviations for all analytes. In addition, the method was specifically tested for the use in post mortem analysis. The applicability of our method was demonstrated by the analysis of two authentic human autopsy blood samples.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1570023224002058/pdfft?md5=e719d8784cd9b7242b4dd8c7ae9e9e2b&pid=1-s2.0-S1570023224002058-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Toxicologic analysis of 35 drugs in post mortem human blood samples with focus on antihypertensive and antiarrhythmic drugs\",\"authors\":\"Julian Bickel, Hilke Jungen, Alexander Müller, Anne Szewczyk, Benjamin Ondruschka, Stefanie Iwersen-Bergmann\",\"doi\":\"10.1016/j.jchromb.2024.124196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Antiarrhythmic and antihypertensive drugs are frequently encountered in post mortem analysis, and the question may arise as to whether they were administered in therapeutic doses, and if they were taken in accidental, intentional, or suicidal overdose scenarios. Therefore, a novel analytical method was developed and validated for the quantification of 35 drugs with toxicological relevance, including antihypertensive and antiarrhythmic drugs (ajmaline, amlodipine, amiodarone, atenolol, bisoprolol, carvedilol, clonidine, desethylamiodarone, diltiazem, donepezil, doxazosin, dronedarone, esmolol, flecainide, lercanidipine, lidocaine, metoprolol, nebivolol, nimodipine, pindolol, prajmaline, propafenone, propranolol, sotalol, urapidil, and verapamil), as well as other medications commonly found in combination (sildenafil, tadalafil, atorvastatin, clopidogrel, dapoxetine, memantine, pentoxifylline, rivastigmine, and ivabradine). The method enables simultaneous identification and quantification in blood samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS).</p><p>Validation exhibited excellent linearity across the concentration range for all analytes. Precision and accuracy were within acceptable limits, with bias and relative standard deviation (RSD) values consistently below 9 % and 10 %, respectively. Selectivity and specificity assessments confirmed the absence of any interference from contaminants or co-extracted drugs. The method demonstrated very high sensitivity, with limits of detection (LOD) as low as 0.01 ng/ml and limits of quantification (LOQ) as low as 0.04 ng/ml. Extraction recovery exceeded 57.5 % for all analytes except atenolol, and matrix effects were <17 % for all analytes except pindolol. Processed sample stability evaluations revealed consistent results with acceptable deviations for all analytes. In addition, the method was specifically tested for the use in post mortem analysis. The applicability of our method was demonstrated by the analysis of two authentic human autopsy blood samples.</p></div>\",\"PeriodicalId\":348,\"journal\":{\"name\":\"Journal of Chromatography B\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1570023224002058/pdfft?md5=e719d8784cd9b7242b4dd8c7ae9e9e2b&pid=1-s2.0-S1570023224002058-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1570023224002058\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224002058","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Toxicologic analysis of 35 drugs in post mortem human blood samples with focus on antihypertensive and antiarrhythmic drugs
Antiarrhythmic and antihypertensive drugs are frequently encountered in post mortem analysis, and the question may arise as to whether they were administered in therapeutic doses, and if they were taken in accidental, intentional, or suicidal overdose scenarios. Therefore, a novel analytical method was developed and validated for the quantification of 35 drugs with toxicological relevance, including antihypertensive and antiarrhythmic drugs (ajmaline, amlodipine, amiodarone, atenolol, bisoprolol, carvedilol, clonidine, desethylamiodarone, diltiazem, donepezil, doxazosin, dronedarone, esmolol, flecainide, lercanidipine, lidocaine, metoprolol, nebivolol, nimodipine, pindolol, prajmaline, propafenone, propranolol, sotalol, urapidil, and verapamil), as well as other medications commonly found in combination (sildenafil, tadalafil, atorvastatin, clopidogrel, dapoxetine, memantine, pentoxifylline, rivastigmine, and ivabradine). The method enables simultaneous identification and quantification in blood samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS).
Validation exhibited excellent linearity across the concentration range for all analytes. Precision and accuracy were within acceptable limits, with bias and relative standard deviation (RSD) values consistently below 9 % and 10 %, respectively. Selectivity and specificity assessments confirmed the absence of any interference from contaminants or co-extracted drugs. The method demonstrated very high sensitivity, with limits of detection (LOD) as low as 0.01 ng/ml and limits of quantification (LOQ) as low as 0.04 ng/ml. Extraction recovery exceeded 57.5 % for all analytes except atenolol, and matrix effects were <17 % for all analytes except pindolol. Processed sample stability evaluations revealed consistent results with acceptable deviations for all analytes. In addition, the method was specifically tested for the use in post mortem analysis. The applicability of our method was demonstrated by the analysis of two authentic human autopsy blood samples.
期刊介绍:
The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis.
Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches.
Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.