骨结合体外研究:评估表面修饰对牙科植入物稳定性的影响

IF 0.8 Q3 Pharmacology, Toxicology and Pharmaceutics Journal of Pharmacy and Bioallied Sciences Pub Date : 2024-06-08 DOI:10.4103/jpbs.jpbs_328_24
M. Sghaireen, M. K. Alam, Ahmed Azhari Salih Mohamedeissa, J. Kazma
{"title":"骨结合体外研究:评估表面修饰对牙科植入物稳定性的影响","authors":"M. Sghaireen, M. K. Alam, Ahmed Azhari Salih Mohamedeissa, J. Kazma","doi":"10.4103/jpbs.jpbs_328_24","DOIUrl":null,"url":null,"abstract":"ABSTRACT\n \n \n \n Osseointegration is critical for the success of dental implants. Surface modifications of dental implants play a crucial role in enhancing osseointegration and implant stability. This in-vitro study aims to evaluate the influence of various surface modifications on dental implant stability.\n \n \n \n Dental implants with different surface modifications were prepared and subjected to in-vitro testing. Surface modifications included sandblasting, acid etching, and plasma spraying. Implant stability was assessed using resonance frequency analysis (RFA) and pull-out tests. Statistical analysis was performed to compare the stability of implants with different surface modifications.\n \n \n \n The results showed that implants with sandblasted and acid-etched surfaces exhibited significantly higher stability compared with those with only a machined surface. The mean RFA values for sandblasted and acid-etched implants were 75 ± 5 and 80 ± 6, respectively, whereas machined implants recorded a mean RFA value of 60 ± 4. Similarly, pull-out tests demonstrated higher maximum tensile strengths for sandblasted and acid-etched implants compared with machined implants.\n \n \n \n Surface modifications, such as sandblasting and acid etching, significantly enhance dental implant stability in vitro. These modifications promote better osseointegration, which is crucial for the long-term success of dental implants in clinical practice.\n","PeriodicalId":16824,"journal":{"name":"Journal of Pharmacy and Bioallied Sciences","volume":" 40","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In-Vitro Study of Osseointegration: Evaluating the Influence of Surface Modifications on Dental Implant Stability\",\"authors\":\"M. Sghaireen, M. K. Alam, Ahmed Azhari Salih Mohamedeissa, J. Kazma\",\"doi\":\"10.4103/jpbs.jpbs_328_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT\\n \\n \\n \\n Osseointegration is critical for the success of dental implants. Surface modifications of dental implants play a crucial role in enhancing osseointegration and implant stability. This in-vitro study aims to evaluate the influence of various surface modifications on dental implant stability.\\n \\n \\n \\n Dental implants with different surface modifications were prepared and subjected to in-vitro testing. Surface modifications included sandblasting, acid etching, and plasma spraying. Implant stability was assessed using resonance frequency analysis (RFA) and pull-out tests. Statistical analysis was performed to compare the stability of implants with different surface modifications.\\n \\n \\n \\n The results showed that implants with sandblasted and acid-etched surfaces exhibited significantly higher stability compared with those with only a machined surface. The mean RFA values for sandblasted and acid-etched implants were 75 ± 5 and 80 ± 6, respectively, whereas machined implants recorded a mean RFA value of 60 ± 4. Similarly, pull-out tests demonstrated higher maximum tensile strengths for sandblasted and acid-etched implants compared with machined implants.\\n \\n \\n \\n Surface modifications, such as sandblasting and acid etching, significantly enhance dental implant stability in vitro. These modifications promote better osseointegration, which is crucial for the long-term success of dental implants in clinical practice.\\n\",\"PeriodicalId\":16824,\"journal\":{\"name\":\"Journal of Pharmacy and Bioallied Sciences\",\"volume\":\" 40\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Pharmacy and Bioallied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jpbs.jpbs_328_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmacy and Bioallied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jpbs.jpbs_328_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

摘要

摘要 骨结合是种植牙成功的关键。牙科种植体的表面改良在增强骨结合和种植体稳定性方面起着至关重要的作用。本体外研究旨在评估各种表面修饰对牙科种植体稳定性的影响。 研究人员制备了不同表面修饰的牙科种植体,并对其进行了体外测试。表面改性包括喷砂、酸蚀和等离子喷涂。使用共振频率分析(RFA)和拔出试验评估种植体的稳定性。通过统计分析,比较了不同表面修饰的种植体的稳定性。 结果表明,表面喷砂和酸蚀的种植体与仅有机加工表面的种植体相比,稳定性明显更高。喷砂和酸蚀种植体的平均 RFA 值分别为 75 ± 5 和 80 ± 6,而机加工种植体的平均 RFA 值为 60 ± 4。 同样,拉拔测试显示,喷砂和酸蚀种植体的最大拉伸强度高于机加工种植体。 喷砂和酸蚀等表面改良技术可显著提高牙科种植体在体外的稳定性。这些改良能促进更好的骨结合,这对牙科种植体在临床实践中的长期成功至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In-Vitro Study of Osseointegration: Evaluating the Influence of Surface Modifications on Dental Implant Stability
ABSTRACT Osseointegration is critical for the success of dental implants. Surface modifications of dental implants play a crucial role in enhancing osseointegration and implant stability. This in-vitro study aims to evaluate the influence of various surface modifications on dental implant stability. Dental implants with different surface modifications were prepared and subjected to in-vitro testing. Surface modifications included sandblasting, acid etching, and plasma spraying. Implant stability was assessed using resonance frequency analysis (RFA) and pull-out tests. Statistical analysis was performed to compare the stability of implants with different surface modifications. The results showed that implants with sandblasted and acid-etched surfaces exhibited significantly higher stability compared with those with only a machined surface. The mean RFA values for sandblasted and acid-etched implants were 75 ± 5 and 80 ± 6, respectively, whereas machined implants recorded a mean RFA value of 60 ± 4. Similarly, pull-out tests demonstrated higher maximum tensile strengths for sandblasted and acid-etched implants compared with machined implants. Surface modifications, such as sandblasting and acid etching, significantly enhance dental implant stability in vitro. These modifications promote better osseointegration, which is crucial for the long-term success of dental implants in clinical practice.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
275
审稿时长
34 weeks
期刊介绍: Journal of Pharmacy And Bioallied Sciences is a Quarterly multidisciplinary open access biomedical journal. Journal of Pharmacy And Bioallied Sciences is an international medium of interaction between scientist, academicians and industrial personnel’s.JPBS is now offial publication of OPUBS.
期刊最新文献
The Role of Tele-Orthodontics in Enhancing Patient Compliance and Treatment Monitoring Exploring the Therapeutic Potential of Omega-3 Fatty Acid Supplementation in Dry Eye Syndrome: An In vitro Investigation Enhancing Precision in Endodontic Procedures: An In vitro Investigation of Magnification and Enhanced Visualization Comparative Evaluation of Surgical Techniques for Pterygium Management: An In Vitro Study Schoolchildren’s Musculoskeletal Pain and Backpack Weight Impact on Posture: A Short-Term Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1