用零价铁和硫化铁填料填装的连续流动色谱柱作为补救持久性污染物硝基胍的可行策略

IF 5 Q1 ENGINEERING, MULTIDISCIPLINARY Defence Technology(防务技术) Pub Date : 2025-01-01 DOI:10.1016/j.dt.2024.06.001
Youngjae Yu , Erika E. Rios-Valenciana , Robert A. Root , Reyes Sierra-Alvarez , Jon Chorover , Jim A. Field
{"title":"用零价铁和硫化铁填料填装的连续流动色谱柱作为补救持久性污染物硝基胍的可行策略","authors":"Youngjae Yu ,&nbsp;Erika E. Rios-Valenciana ,&nbsp;Robert A. Root ,&nbsp;Reyes Sierra-Alvarez ,&nbsp;Jon Chorover ,&nbsp;Jim A. Field","doi":"10.1016/j.dt.2024.06.001","DOIUrl":null,"url":null,"abstract":"<div><div>The insensitive munitions compound nitroguanidine (NQ) is used by the U.S. Army to avoid unintended explosions. However, NQ also represents an emerging contaminant whose environmental emissions can cause toxicity toward aquatic organisms, indicating the need for effective remediation strategies. Thus, we investigated the feasibility of treating water contaminated with NQ in continuous-flow columns packed with zero-valent iron (ZVI) or iron sulfide (FeS). Initially, the impact of pH on NQ transformation by ZVI or FeS was evaluated in batch experiments. The pseudo first-order rate constant for NQ transformation (<em>k</em><sub>1, NQ</sub>) by ZVI was 8–10 times higher at pH 3.0 compared to pH 5.5 and 7.0, whereas similar <em>k</em><sub>1, NQ</sub> values were obtained for FeS at pH 5.5–10.0. Based on these findings, the influent pH fed to the ZVI- and FeS-packed columns was adjusted to 3.0 and 5.5, respectively. Both reactors transformed NQ into nitrosoguanidine (NsoQ). Further transformation of NsoQ by ZVI produced aminoguanidine, guanidine, and cyanamide, whereas NsoQ transformation by FeS produced guanidine, ammonium, and traces of urea. ZVI outperformed FeS as a reactive material to remove NQ. The ZVI-packed column effectively removed NQ below detection even after 45 d of operation (490 pore volumes, PV). In contrast, NQ breakthrough (removal efficiency &lt;85%) was observed after 18 d (180 PV) in the FeS-packed column. The high NQ removal efficiency and long service life of the ZVI-packed column (&gt;490 PV) suggest that the technology is a promising approach for NQ treatment in packed-bed reactors and <em>in situ</em> remediation.</div></div>","PeriodicalId":58209,"journal":{"name":"Defence Technology(防务技术)","volume":"43 ","pages":"Pages 26-34"},"PeriodicalIF":5.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous-flow columns packed with zero-valent iron and iron sulfide as a feasible strategy to remediate the persistent contaminant nitroguanidine\",\"authors\":\"Youngjae Yu ,&nbsp;Erika E. Rios-Valenciana ,&nbsp;Robert A. Root ,&nbsp;Reyes Sierra-Alvarez ,&nbsp;Jon Chorover ,&nbsp;Jim A. Field\",\"doi\":\"10.1016/j.dt.2024.06.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The insensitive munitions compound nitroguanidine (NQ) is used by the U.S. Army to avoid unintended explosions. However, NQ also represents an emerging contaminant whose environmental emissions can cause toxicity toward aquatic organisms, indicating the need for effective remediation strategies. Thus, we investigated the feasibility of treating water contaminated with NQ in continuous-flow columns packed with zero-valent iron (ZVI) or iron sulfide (FeS). Initially, the impact of pH on NQ transformation by ZVI or FeS was evaluated in batch experiments. The pseudo first-order rate constant for NQ transformation (<em>k</em><sub>1, NQ</sub>) by ZVI was 8–10 times higher at pH 3.0 compared to pH 5.5 and 7.0, whereas similar <em>k</em><sub>1, NQ</sub> values were obtained for FeS at pH 5.5–10.0. Based on these findings, the influent pH fed to the ZVI- and FeS-packed columns was adjusted to 3.0 and 5.5, respectively. Both reactors transformed NQ into nitrosoguanidine (NsoQ). Further transformation of NsoQ by ZVI produced aminoguanidine, guanidine, and cyanamide, whereas NsoQ transformation by FeS produced guanidine, ammonium, and traces of urea. ZVI outperformed FeS as a reactive material to remove NQ. The ZVI-packed column effectively removed NQ below detection even after 45 d of operation (490 pore volumes, PV). In contrast, NQ breakthrough (removal efficiency &lt;85%) was observed after 18 d (180 PV) in the FeS-packed column. The high NQ removal efficiency and long service life of the ZVI-packed column (&gt;490 PV) suggest that the technology is a promising approach for NQ treatment in packed-bed reactors and <em>in situ</em> remediation.</div></div>\",\"PeriodicalId\":58209,\"journal\":{\"name\":\"Defence Technology(防务技术)\",\"volume\":\"43 \",\"pages\":\"Pages 26-34\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Defence Technology(防务技术)\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S221491472400134X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Defence Technology(防务技术)","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221491472400134X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continuous-flow columns packed with zero-valent iron and iron sulfide as a feasible strategy to remediate the persistent contaminant nitroguanidine
The insensitive munitions compound nitroguanidine (NQ) is used by the U.S. Army to avoid unintended explosions. However, NQ also represents an emerging contaminant whose environmental emissions can cause toxicity toward aquatic organisms, indicating the need for effective remediation strategies. Thus, we investigated the feasibility of treating water contaminated with NQ in continuous-flow columns packed with zero-valent iron (ZVI) or iron sulfide (FeS). Initially, the impact of pH on NQ transformation by ZVI or FeS was evaluated in batch experiments. The pseudo first-order rate constant for NQ transformation (k1, NQ) by ZVI was 8–10 times higher at pH 3.0 compared to pH 5.5 and 7.0, whereas similar k1, NQ values were obtained for FeS at pH 5.5–10.0. Based on these findings, the influent pH fed to the ZVI- and FeS-packed columns was adjusted to 3.0 and 5.5, respectively. Both reactors transformed NQ into nitrosoguanidine (NsoQ). Further transformation of NsoQ by ZVI produced aminoguanidine, guanidine, and cyanamide, whereas NsoQ transformation by FeS produced guanidine, ammonium, and traces of urea. ZVI outperformed FeS as a reactive material to remove NQ. The ZVI-packed column effectively removed NQ below detection even after 45 d of operation (490 pore volumes, PV). In contrast, NQ breakthrough (removal efficiency <85%) was observed after 18 d (180 PV) in the FeS-packed column. The high NQ removal efficiency and long service life of the ZVI-packed column (>490 PV) suggest that the technology is a promising approach for NQ treatment in packed-bed reactors and in situ remediation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Defence Technology(防务技术)
Defence Technology(防务技术) Mechanical Engineering, Control and Systems Engineering, Industrial and Manufacturing Engineering
CiteScore
8.70
自引率
0.00%
发文量
728
审稿时长
25 days
期刊介绍: Defence Technology, a peer reviewed journal, is published monthly and aims to become the best international academic exchange platform for the research related to defence technology. It publishes original research papers having direct bearing on defence, with a balanced coverage on analytical, experimental, numerical simulation and applied investigations. It covers various disciplines of science, technology and engineering.
期刊最新文献
IFC - Editorial Board Perspectives on additive manufacturing for warhead applications Innovative dispersion techniques of graphene nanoplatelets (GNPs) through mechanical stirring and ultrasonication: Impact on morphological, mechanical, and thermal properties of epoxy nanocomposites Discovering causal models for structural, construction and defense-related engineering phenomena Synergistic effect of nitrocellulose coating on structural and reactivity stabilization of ammonium nitrate oxidizer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1