María Cayeiro-Marín , Javier Merino-Andrés , Álvaro Hidalgo-Robles , Arturo Ladriñán-Maestro , Alberto Sánchez-Sierra
{"title":"肺功能改善装置对脑瘫儿的影响:随机临床试验的系统回顾和荟萃分析","authors":"María Cayeiro-Marín , Javier Merino-Andrés , Álvaro Hidalgo-Robles , Arturo Ladriñán-Maestro , Alberto Sánchez-Sierra","doi":"10.1016/j.rmed.2024.107717","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Enhancing lung function can significantly improve daily life functionality for children with cerebral palsy, leading to increased interest in respiratory physiotherapy training devices in clinical practice. This study aims to evaluate the efficacy of devices (inspiratory muscle training and feedback devices) for improving pulmonary function through various respiratory parameters.</p></div><div><h3>Methods</h3><p>A systematic review with meta-analysis of randomized clinical trials was conducted in seven databases up until May 2023. The included studies focused on training inspiratory muscle function using specific devices (inspiratory muscle training and feedback devices) in children with cerebral palsy. The main outcomes were maximum expiratory pressure and maximum inspiratory pressure. Secondary outcomes included forced vital capacity, forced expiratory volume in 1 s, peak expiratory flow, and the Tiffenau index. The effects of respiratory treatment were calculated through the estimation of the effect size and its 95% confidence intervals. The risk of bias in the included studies was assessed using the Cochrane Collaboration's tool for assessing the risk of bias (RoB2).</p></div><div><h3>Results</h3><p>Nine studies were included in the systematic review with meta-analysis, involving a total of 321 children aged between 6 and 18 years after secondary analyses were conducted. Feedback devices were found to be more effective in improving maximum expiratory pressure (effect size −0.604; confidence interval −1.368 to 0.161), peak expiratory flow, forced expiratory volume in 1 s, and forced vital capacity. Inspiratory muscle training devices yielded better effectiveness in improving maximum inspiratory pressure (effect size −0.500; confidence interval −1.259 to 0.259), the Tiffeneau index, and quality of life.</p></div><div><h3>Conclusion</h3><p>Both devices showed potential in improving pulmonary function in children with cerebral palsy. Further high-quality clinical trials are needed to determine the optimal dosage and the most beneficial device type for each pulmonary function parameter.</p></div>","PeriodicalId":21057,"journal":{"name":"Respiratory medicine","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of pulmonary function improvement devices in the pediatric population with cerebral palsy: Systematic review and meta-analysis of randomized clinical trials\",\"authors\":\"María Cayeiro-Marín , Javier Merino-Andrés , Álvaro Hidalgo-Robles , Arturo Ladriñán-Maestro , Alberto Sánchez-Sierra\",\"doi\":\"10.1016/j.rmed.2024.107717\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Enhancing lung function can significantly improve daily life functionality for children with cerebral palsy, leading to increased interest in respiratory physiotherapy training devices in clinical practice. This study aims to evaluate the efficacy of devices (inspiratory muscle training and feedback devices) for improving pulmonary function through various respiratory parameters.</p></div><div><h3>Methods</h3><p>A systematic review with meta-analysis of randomized clinical trials was conducted in seven databases up until May 2023. The included studies focused on training inspiratory muscle function using specific devices (inspiratory muscle training and feedback devices) in children with cerebral palsy. The main outcomes were maximum expiratory pressure and maximum inspiratory pressure. Secondary outcomes included forced vital capacity, forced expiratory volume in 1 s, peak expiratory flow, and the Tiffenau index. The effects of respiratory treatment were calculated through the estimation of the effect size and its 95% confidence intervals. The risk of bias in the included studies was assessed using the Cochrane Collaboration's tool for assessing the risk of bias (RoB2).</p></div><div><h3>Results</h3><p>Nine studies were included in the systematic review with meta-analysis, involving a total of 321 children aged between 6 and 18 years after secondary analyses were conducted. Feedback devices were found to be more effective in improving maximum expiratory pressure (effect size −0.604; confidence interval −1.368 to 0.161), peak expiratory flow, forced expiratory volume in 1 s, and forced vital capacity. Inspiratory muscle training devices yielded better effectiveness in improving maximum inspiratory pressure (effect size −0.500; confidence interval −1.259 to 0.259), the Tiffeneau index, and quality of life.</p></div><div><h3>Conclusion</h3><p>Both devices showed potential in improving pulmonary function in children with cerebral palsy. Further high-quality clinical trials are needed to determine the optimal dosage and the most beneficial device type for each pulmonary function parameter.</p></div>\",\"PeriodicalId\":21057,\"journal\":{\"name\":\"Respiratory medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Respiratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0954611124001926\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiratory medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0954611124001926","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Effects of pulmonary function improvement devices in the pediatric population with cerebral palsy: Systematic review and meta-analysis of randomized clinical trials
Introduction
Enhancing lung function can significantly improve daily life functionality for children with cerebral palsy, leading to increased interest in respiratory physiotherapy training devices in clinical practice. This study aims to evaluate the efficacy of devices (inspiratory muscle training and feedback devices) for improving pulmonary function through various respiratory parameters.
Methods
A systematic review with meta-analysis of randomized clinical trials was conducted in seven databases up until May 2023. The included studies focused on training inspiratory muscle function using specific devices (inspiratory muscle training and feedback devices) in children with cerebral palsy. The main outcomes were maximum expiratory pressure and maximum inspiratory pressure. Secondary outcomes included forced vital capacity, forced expiratory volume in 1 s, peak expiratory flow, and the Tiffenau index. The effects of respiratory treatment were calculated through the estimation of the effect size and its 95% confidence intervals. The risk of bias in the included studies was assessed using the Cochrane Collaboration's tool for assessing the risk of bias (RoB2).
Results
Nine studies were included in the systematic review with meta-analysis, involving a total of 321 children aged between 6 and 18 years after secondary analyses were conducted. Feedback devices were found to be more effective in improving maximum expiratory pressure (effect size −0.604; confidence interval −1.368 to 0.161), peak expiratory flow, forced expiratory volume in 1 s, and forced vital capacity. Inspiratory muscle training devices yielded better effectiveness in improving maximum inspiratory pressure (effect size −0.500; confidence interval −1.259 to 0.259), the Tiffeneau index, and quality of life.
Conclusion
Both devices showed potential in improving pulmonary function in children with cerebral palsy. Further high-quality clinical trials are needed to determine the optimal dosage and the most beneficial device type for each pulmonary function parameter.
期刊介绍:
Respiratory Medicine is an internationally-renowned journal devoted to the rapid publication of clinically-relevant respiratory medicine research. It combines cutting-edge original research with state-of-the-art reviews dealing with all aspects of respiratory diseases and therapeutic interventions. Topics include adult and paediatric medicine, epidemiology, immunology and cell biology, physiology, occupational disorders, and the role of allergens and pollutants.
Respiratory Medicine is increasingly the journal of choice for publication of phased trial work, commenting on effectiveness, dosage and methods of action.