干血斑采样与液相色谱-串联质谱联用,用于同时定量分析多种心血管药物。

IF 2.8 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Journal of Chromatography B Pub Date : 2024-06-22 DOI:10.1016/j.jchromb.2024.124215
Mariam M. Abady , Ji-Seon Jeong , Ha-Jeong Kwon
{"title":"干血斑采样与液相色谱-串联质谱联用,用于同时定量分析多种心血管药物。","authors":"Mariam M. Abady ,&nbsp;Ji-Seon Jeong ,&nbsp;Ha-Jeong Kwon","doi":"10.1016/j.jchromb.2024.124215","DOIUrl":null,"url":null,"abstract":"<div><p>Dried Blood Spots (DBS) revolutionize therapeutic drug monitoring using LC-MS for the precise quantification of cardiovascular drugs (CDs), enabling personalized treatment adapted to patient-specific pharmacokinetics with minimal invasiveness. This study aims to achieve simultaneous quantification of eight CDs in DBS, overcoming physicochemical challenges. A two-step protein precipitation method was used for simple and precise sample preparation. The drugs were analyzed using LC-MS/MS in ESI positive-ion mode, showing high sensitivity and linearity, with a correlation coefficient (r<sup>2</sup>) exceeding 0.999, after being separated on a reversed-phase chromatography by gradient elution of DW-acetonitrile containing 0.1 % formic acid + 2 mM ammonium formate. The validation results indicate good selectivity, with no observed matrix effect and carry-over. The intra- and inter-day accuracy and precision were within 6 % for most drugs, except for digoxin and deslanoside at low therapeutic levels where the variation was within 20 %. Stability tests confirmed suitable DBS handling and storage conditions, indicating drug stability for at least 30 days at room temperature. The analysis of whole spot has demonstrated remarkable precision and reliability in all target drugs. The analysis of 3 mm internal diameter discs, punched in and out of DBS, presumed to contain 3 µL of blood, showed acceptable accuracy for most drugs, with less polar drugs like digoxin and deslanoside showing lower accuracy, indicating a need for further correction due to non-uniform drug distribution. Consequently, the developed LC-MS/MS method enables the quantification of multiple CDs in a single DBS analysis, while suggesting the potential for accuracy-based analysis.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1570023224002241/pdfft?md5=ca0cb1c4e666e568231a55de37c70bdb&pid=1-s2.0-S1570023224002241-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Dried blood spot sampling coupled with liquid chromatography-tandem mass for simultaneous quantitative analysis of multiple cardiovascular drugs\",\"authors\":\"Mariam M. Abady ,&nbsp;Ji-Seon Jeong ,&nbsp;Ha-Jeong Kwon\",\"doi\":\"10.1016/j.jchromb.2024.124215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Dried Blood Spots (DBS) revolutionize therapeutic drug monitoring using LC-MS for the precise quantification of cardiovascular drugs (CDs), enabling personalized treatment adapted to patient-specific pharmacokinetics with minimal invasiveness. This study aims to achieve simultaneous quantification of eight CDs in DBS, overcoming physicochemical challenges. A two-step protein precipitation method was used for simple and precise sample preparation. The drugs were analyzed using LC-MS/MS in ESI positive-ion mode, showing high sensitivity and linearity, with a correlation coefficient (r<sup>2</sup>) exceeding 0.999, after being separated on a reversed-phase chromatography by gradient elution of DW-acetonitrile containing 0.1 % formic acid + 2 mM ammonium formate. The validation results indicate good selectivity, with no observed matrix effect and carry-over. The intra- and inter-day accuracy and precision were within 6 % for most drugs, except for digoxin and deslanoside at low therapeutic levels where the variation was within 20 %. Stability tests confirmed suitable DBS handling and storage conditions, indicating drug stability for at least 30 days at room temperature. The analysis of whole spot has demonstrated remarkable precision and reliability in all target drugs. The analysis of 3 mm internal diameter discs, punched in and out of DBS, presumed to contain 3 µL of blood, showed acceptable accuracy for most drugs, with less polar drugs like digoxin and deslanoside showing lower accuracy, indicating a need for further correction due to non-uniform drug distribution. Consequently, the developed LC-MS/MS method enables the quantification of multiple CDs in a single DBS analysis, while suggesting the potential for accuracy-based analysis.</p></div>\",\"PeriodicalId\":348,\"journal\":{\"name\":\"Journal of Chromatography B\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1570023224002241/pdfft?md5=ca0cb1c4e666e568231a55de37c70bdb&pid=1-s2.0-S1570023224002241-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1570023224002241\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224002241","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

干血斑(DBS)是利用 LC-MS 对心血管药物(CDs)进行精确定量的治疗药物监测的革命性技术,可根据患者的药代动力学进行个性化治疗,且创伤极小。本研究旨在克服物理化学难题,实现 DBS 中八种 CDs 的同时定量。采用两步蛋白质沉淀法进行简单而精确的样品制备。采用含有 0.1 % 甲酸 + 2 mM 甲酸铵的 DW-乙腈梯度洗脱反相色谱法,在 ESI 正离子模式下进行 LC-MS/MS 分析,结果表明药物的灵敏度高、线性好,相关系数 (r2) 超过 0.999。验证结果表明,该方法具有良好的选择性,未发现基质效应和携带现象。大多数药物的日内和日间准确度和精密度都在 6% 以内,只有地高辛和去羟肌苷在低治疗水平下的差异在 20% 以内。稳定性测试确认了合适的 DBS 处理和储存条件,表明药物在室温下至少可稳定保存 30 天。对所有目标药物的整点分析都显示出显著的精确性和可靠性。从 DBS 中打入和打出的内径为 3 毫米的圆片(假定含有 3 微升血液)的分析表明,大多数药物的准确度可以接受,而地高辛和去羟肌苷等极性较低的药物准确度较低,表明由于药物分布不均匀,需要进一步校正。因此,所开发的 LC-MS/MS 方法能够在一次 DBS 分析中定量检测多种 CD,同时也显示了基于准确度的分析潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dried blood spot sampling coupled with liquid chromatography-tandem mass for simultaneous quantitative analysis of multiple cardiovascular drugs

Dried Blood Spots (DBS) revolutionize therapeutic drug monitoring using LC-MS for the precise quantification of cardiovascular drugs (CDs), enabling personalized treatment adapted to patient-specific pharmacokinetics with minimal invasiveness. This study aims to achieve simultaneous quantification of eight CDs in DBS, overcoming physicochemical challenges. A two-step protein precipitation method was used for simple and precise sample preparation. The drugs were analyzed using LC-MS/MS in ESI positive-ion mode, showing high sensitivity and linearity, with a correlation coefficient (r2) exceeding 0.999, after being separated on a reversed-phase chromatography by gradient elution of DW-acetonitrile containing 0.1 % formic acid + 2 mM ammonium formate. The validation results indicate good selectivity, with no observed matrix effect and carry-over. The intra- and inter-day accuracy and precision were within 6 % for most drugs, except for digoxin and deslanoside at low therapeutic levels where the variation was within 20 %. Stability tests confirmed suitable DBS handling and storage conditions, indicating drug stability for at least 30 days at room temperature. The analysis of whole spot has demonstrated remarkable precision and reliability in all target drugs. The analysis of 3 mm internal diameter discs, punched in and out of DBS, presumed to contain 3 µL of blood, showed acceptable accuracy for most drugs, with less polar drugs like digoxin and deslanoside showing lower accuracy, indicating a need for further correction due to non-uniform drug distribution. Consequently, the developed LC-MS/MS method enables the quantification of multiple CDs in a single DBS analysis, while suggesting the potential for accuracy-based analysis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Chromatography B
Journal of Chromatography B 医学-分析化学
CiteScore
5.60
自引率
3.30%
发文量
306
审稿时长
44 days
期刊介绍: The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis. Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches. Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.
期刊最新文献
An unconventional strategy for purifying recombinant SARS-CoV-2 spike protein. Greener analysis of eleven basic drugs in blood and urine using carbowax 20M based biofluid sampler (BFS) device Preparative separation of ten flavonoids from Scutellaria baicalensis Georgi roots using two-dimensional countercurrent chromatography with an online-storage, dilution, and mixing interface Thin film microextraction of apixaban from plasma based on the covalent organic framework coated on a mesh prior to liquid chromatography-tandem mass spectrometry. Faster liquid chromatography-tandem mass spectrometry method for analysis of isomeric urinary mercapturic acid metabolites of crotonaldehyde, methacrolein, and methyl vinyl ketone
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1