不同表面锁定模式对全牙弓数字化种植体扫描真实性的影响:体外研究。

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2024-09-01 DOI:10.1016/j.prosdent.2024.05.019
{"title":"不同表面锁定模式对全牙弓数字化种植体扫描真实性的影响:体外研究。","authors":"","doi":"10.1016/j.prosdent.2024.05.019","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><p>The effect of different surface locking patterns on the trueness of a digital implant scan of a completely edentulous arch remains uncertain.</p></div><div><h3>Purpose</h3><p>The purpose of this in vitro study was to evaluate whether locking surfaces with different patterns affected the trueness of complete arch implant digital scans.</p></div><div><h3>Material and methods</h3><p><span>An edentulous maxillary cast with 4 implants (2 anterior implants parallel and 2 posterior implants tilted at 17 degrees) was fabricated. Four implant-level scan bodies were fixed onto the implants, and the cast was scanned with a desktop scanner to create the reference file. Four groups (L0, L1, L2, and L3) were formed, each with a distinct locking surface configuration, and all scans were made using the same intraoral scanner. L0 kept all 4 implant-level scan bodies during scanning. L1 involved removing the right </span>first premolar<span> (RPM) scan body, scanning the other 3 implant scan bodies, then reattaching the RPM's scan body, and continuing scanning. In L2, the RPM and right lateral incisor<span> (RIC) scan bodies were removed, followed by scanning the left implants to create a locking surface, and scanning the right implants. In L3, only the left posterior molar’s (LPM) scan body was retained and scanned; then a locking surface was generated, and then the remaining implants were scanned. A metrology software program (Geomagic Control X) was used for comparison. Statistical analyses were performed using the Kruskal-Wallis, the 1-way ANOVA, the Welch ANOVA, the Friedman test<span>, the repeated-measures ANOVA, the Bonferroni post hoc test, and the Games-Howell post hoc test (α=.05).</span></span></span></p></div><div><h3>Results</h3><p>Significant 3D surface deviations were observed in the coronal bevel (CB) region and in the entire scan bodies when assessing trueness in the L0, L1, L2, and L3 groups (<em>P</em>&lt;.001). L2 exhibited the highest discrepancies in 3D surface deviation for CB (0.030 ±0.002 mm) and implant scan bodies (0.357 ±0.052 mm) and distance deviation, while the highest mean angular deviation values were found in L0 (0.924 ±0.131 degrees).</p></div><div><h3>Conclusions</h3><p>Locking half of the arch showed the highest trueness discrepancies when performing digital scans for complete arch implant-supported prostheses.</p></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of different surface locking patterns on the trueness of complete arch digital implant scans: An in vitro study\",\"authors\":\"\",\"doi\":\"10.1016/j.prosdent.2024.05.019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Statement of problem</h3><p>The effect of different surface locking patterns on the trueness of a digital implant scan of a completely edentulous arch remains uncertain.</p></div><div><h3>Purpose</h3><p>The purpose of this in vitro study was to evaluate whether locking surfaces with different patterns affected the trueness of complete arch implant digital scans.</p></div><div><h3>Material and methods</h3><p><span>An edentulous maxillary cast with 4 implants (2 anterior implants parallel and 2 posterior implants tilted at 17 degrees) was fabricated. Four implant-level scan bodies were fixed onto the implants, and the cast was scanned with a desktop scanner to create the reference file. Four groups (L0, L1, L2, and L3) were formed, each with a distinct locking surface configuration, and all scans were made using the same intraoral scanner. L0 kept all 4 implant-level scan bodies during scanning. L1 involved removing the right </span>first premolar<span> (RPM) scan body, scanning the other 3 implant scan bodies, then reattaching the RPM's scan body, and continuing scanning. In L2, the RPM and right lateral incisor<span> (RIC) scan bodies were removed, followed by scanning the left implants to create a locking surface, and scanning the right implants. In L3, only the left posterior molar’s (LPM) scan body was retained and scanned; then a locking surface was generated, and then the remaining implants were scanned. A metrology software program (Geomagic Control X) was used for comparison. Statistical analyses were performed using the Kruskal-Wallis, the 1-way ANOVA, the Welch ANOVA, the Friedman test<span>, the repeated-measures ANOVA, the Bonferroni post hoc test, and the Games-Howell post hoc test (α=.05).</span></span></span></p></div><div><h3>Results</h3><p>Significant 3D surface deviations were observed in the coronal bevel (CB) region and in the entire scan bodies when assessing trueness in the L0, L1, L2, and L3 groups (<em>P</em>&lt;.001). L2 exhibited the highest discrepancies in 3D surface deviation for CB (0.030 ±0.002 mm) and implant scan bodies (0.357 ±0.052 mm) and distance deviation, while the highest mean angular deviation values were found in L0 (0.924 ±0.131 degrees).</p></div><div><h3>Conclusions</h3><p>Locking half of the arch showed the highest trueness discrepancies when performing digital scans for complete arch implant-supported prostheses.</p></div>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022391324003706\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391324003706","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

问题陈述:不同的表面锁定模式对全口无牙颌数字种植体扫描真实性的影响仍不确定。目的:本体外研究的目的是评估不同模式的锁定表面是否会影响全口无牙颌数字种植体扫描的真实性:材料:制作了一个带有 4 个种植体(2 个前部种植体平行,2 个后部种植体倾斜 17 度)的无牙上颌模型。将四个种植体水平扫描体固定在种植体上,然后使用台式扫描仪对石膏进行扫描,以创建参考文件。共分为四组(L0、L1、L2 和 L3),每组都有不同的锁定面结构,所有扫描都使用同一台口内扫描仪进行。L0 在扫描过程中保留了所有 4 个种植体的扫描体。L1 需要移除右侧第一前磨牙(RPM)扫描体,扫描其他 3 个种植体扫描体,然后重新连接 RPM 的扫描体,继续扫描。在 L2 中,移除 RPM 和右侧切牙(RIC)扫描体,然后扫描左侧种植体以形成锁定面,再扫描右侧种植体。在 L3 中,只保留并扫描左后臼齿(LPM)的扫描体,然后生成锁定面,再扫描其余的种植体。使用计量软件程序(Geomagic Control X)进行比较。使用 Kruskal-Wallis、单因素方差分析、Welch 方差分析、Friedman 检验、重复测量方差分析、Bonferroni 后检验和 Games-Howell 后检验(α=.05)进行统计分析:在评估L0、L1、L2和L3组的真实度时,在冠状斜面(CB)区域和整个扫描体上观察到明显的三维表面偏差(PConclusions:在对全牙弓种植体支撑修复体进行数字扫描时,锁定的半牙弓显示出最大的真实度偏差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of different surface locking patterns on the trueness of complete arch digital implant scans: An in vitro study

Statement of problem

The effect of different surface locking patterns on the trueness of a digital implant scan of a completely edentulous arch remains uncertain.

Purpose

The purpose of this in vitro study was to evaluate whether locking surfaces with different patterns affected the trueness of complete arch implant digital scans.

Material and methods

An edentulous maxillary cast with 4 implants (2 anterior implants parallel and 2 posterior implants tilted at 17 degrees) was fabricated. Four implant-level scan bodies were fixed onto the implants, and the cast was scanned with a desktop scanner to create the reference file. Four groups (L0, L1, L2, and L3) were formed, each with a distinct locking surface configuration, and all scans were made using the same intraoral scanner. L0 kept all 4 implant-level scan bodies during scanning. L1 involved removing the right first premolar (RPM) scan body, scanning the other 3 implant scan bodies, then reattaching the RPM's scan body, and continuing scanning. In L2, the RPM and right lateral incisor (RIC) scan bodies were removed, followed by scanning the left implants to create a locking surface, and scanning the right implants. In L3, only the left posterior molar’s (LPM) scan body was retained and scanned; then a locking surface was generated, and then the remaining implants were scanned. A metrology software program (Geomagic Control X) was used for comparison. Statistical analyses were performed using the Kruskal-Wallis, the 1-way ANOVA, the Welch ANOVA, the Friedman test, the repeated-measures ANOVA, the Bonferroni post hoc test, and the Games-Howell post hoc test (α=.05).

Results

Significant 3D surface deviations were observed in the coronal bevel (CB) region and in the entire scan bodies when assessing trueness in the L0, L1, L2, and L3 groups (P<.001). L2 exhibited the highest discrepancies in 3D surface deviation for CB (0.030 ±0.002 mm) and implant scan bodies (0.357 ±0.052 mm) and distance deviation, while the highest mean angular deviation values were found in L0 (0.924 ±0.131 degrees).

Conclusions

Locking half of the arch showed the highest trueness discrepancies when performing digital scans for complete arch implant-supported prostheses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
A method for decontaminating a dental implant and components after abutment screw loosening: A clinical report. Effect of machining method and margin design on the accuracy and margin quality of monolithic zirconia crowns. A digital workflow for recording implant positions and jaw relation for implant-supported complete arch prostheses. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. Prosthodontic rehabilitation of a patient after mucormycosis using a digitally fabricated hollow complete denture with 3D printed intramucosal inserts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1