两种不同三维钢板治疗下颌角骨折的临床效果:回顾性分析。

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Oral and Maxillofacial Surgery-Heidelberg Pub Date : 2024-12-01 Epub Date: 2024-06-26 DOI:10.1007/s10006-024-01275-6
Jelena Pfister, Farah Nur Shazwani, Martin Müller, John-Patrik Burkhard
{"title":"两种不同三维钢板治疗下颌角骨折的临床效果:回顾性分析。","authors":"Jelena Pfister, Farah Nur Shazwani, Martin Müller, John-Patrik Burkhard","doi":"10.1007/s10006-024-01275-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The purpose of this study was to compare two different designs of three-dimensional osteosynthesis plates for their suitability in the treatment of mandibular angle fractures in terms of sufficient fracture healing and concomitant complications.</p><p><strong>Materials and methods: </strong>Retrospectively a total of 54 patients with 56 mandibular angle fractures were evaluated. Two different types of three-dimensional plates from the Medartis Trilock system were analyzed: (A) Square design plate (☐-plate) with a thickness of 1.0 mm, and (B) triangular-shaped 3D-plate (△-plate) with a thickness of 1.3 mm. Patient demographics, fracture mechanism and intraoperative details were recorded during an average follow-up period of 1 year.</p><p><strong>Results: </strong>The utilization of △-plates was observed to entail a considerably lengthier surgical time in contrast to ☐-plate systems (P = 0.037). The application of △-plate showed a tendency of higher incidence of major complications than ☐-plate (P = 0.06), as evidenced by the occurrence of non-union in 2 out of 22 cases, resulting in higher surgical revision rate for △-plate (P = 0.027).</p><p><strong>Conclusion: </strong>Sufficient treatment of mandibular angle fractures is feasible by using 1.0 mm thick, square shaped three-dimensional plate systems. The use of thicker three-dimensional osteosynthesis plates seems to significantly increase the operating time and complication rates, whereby the geometry of the plate seems to have an influence.</p><p><strong>Clinical relevance: </strong>The plate design could have an impact on treatment outcomes of mandibular angle fractures.</p><p><strong>Trial registration number: </strong>Not applicable.</p>","PeriodicalId":47251,"journal":{"name":"Oral and Maxillofacial Surgery-Heidelberg","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11481679/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinical results of two different three-dimensional plate types for the treatment of mandibular angle fractures: a retrospective analysis.\",\"authors\":\"Jelena Pfister, Farah Nur Shazwani, Martin Müller, John-Patrik Burkhard\",\"doi\":\"10.1007/s10006-024-01275-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The purpose of this study was to compare two different designs of three-dimensional osteosynthesis plates for their suitability in the treatment of mandibular angle fractures in terms of sufficient fracture healing and concomitant complications.</p><p><strong>Materials and methods: </strong>Retrospectively a total of 54 patients with 56 mandibular angle fractures were evaluated. Two different types of three-dimensional plates from the Medartis Trilock system were analyzed: (A) Square design plate (☐-plate) with a thickness of 1.0 mm, and (B) triangular-shaped 3D-plate (△-plate) with a thickness of 1.3 mm. Patient demographics, fracture mechanism and intraoperative details were recorded during an average follow-up period of 1 year.</p><p><strong>Results: </strong>The utilization of △-plates was observed to entail a considerably lengthier surgical time in contrast to ☐-plate systems (P = 0.037). The application of △-plate showed a tendency of higher incidence of major complications than ☐-plate (P = 0.06), as evidenced by the occurrence of non-union in 2 out of 22 cases, resulting in higher surgical revision rate for △-plate (P = 0.027).</p><p><strong>Conclusion: </strong>Sufficient treatment of mandibular angle fractures is feasible by using 1.0 mm thick, square shaped three-dimensional plate systems. The use of thicker three-dimensional osteosynthesis plates seems to significantly increase the operating time and complication rates, whereby the geometry of the plate seems to have an influence.</p><p><strong>Clinical relevance: </strong>The plate design could have an impact on treatment outcomes of mandibular angle fractures.</p><p><strong>Trial registration number: </strong>Not applicable.</p>\",\"PeriodicalId\":47251,\"journal\":{\"name\":\"Oral and Maxillofacial Surgery-Heidelberg\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11481679/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oral and Maxillofacial Surgery-Heidelberg\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s10006-024-01275-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral and Maxillofacial Surgery-Heidelberg","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10006-024-01275-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是比较两种不同设计的三维骨整合钢板在治疗下颌角骨折时,在骨折充分愈合和伴随并发症方面的适用性:回顾性评估了56例下颌角骨折的54名患者。分析了 Medartis Trilock 系统的两种不同类型的三维钢板:(A) 厚度为 1.0 mm 的方形设计钢板(☐-plate)和 (B) 厚度为 1.3 mm 的三角形三维钢板(△-plate)。在平均 1 年的随访期间,记录了患者的人口统计学特征、骨折机制和术中细节:结果:与☐-钢板系统相比,使用△-钢板需要更长的手术时间(P = 0.037)。22例中有2例发生了不愈合,这证明△-钢板的主要并发症发生率高于☐-钢板(P = 0.06),从而导致△-钢板的手术翻修率较高(P = 0.027):结论:使用 1.0 毫米厚的方形三维骨板系统可以充分治疗下颌角骨折。使用更厚的三维接骨板似乎会显著增加手术时间和并发症发生率,而接骨板的几何形状似乎也有影响:临床相关性:钢板设计可能会影响下颌角骨折的治疗效果:不适用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical results of two different three-dimensional plate types for the treatment of mandibular angle fractures: a retrospective analysis.

Objectives: The purpose of this study was to compare two different designs of three-dimensional osteosynthesis plates for their suitability in the treatment of mandibular angle fractures in terms of sufficient fracture healing and concomitant complications.

Materials and methods: Retrospectively a total of 54 patients with 56 mandibular angle fractures were evaluated. Two different types of three-dimensional plates from the Medartis Trilock system were analyzed: (A) Square design plate (☐-plate) with a thickness of 1.0 mm, and (B) triangular-shaped 3D-plate (△-plate) with a thickness of 1.3 mm. Patient demographics, fracture mechanism and intraoperative details were recorded during an average follow-up period of 1 year.

Results: The utilization of △-plates was observed to entail a considerably lengthier surgical time in contrast to ☐-plate systems (P = 0.037). The application of △-plate showed a tendency of higher incidence of major complications than ☐-plate (P = 0.06), as evidenced by the occurrence of non-union in 2 out of 22 cases, resulting in higher surgical revision rate for △-plate (P = 0.027).

Conclusion: Sufficient treatment of mandibular angle fractures is feasible by using 1.0 mm thick, square shaped three-dimensional plate systems. The use of thicker three-dimensional osteosynthesis plates seems to significantly increase the operating time and complication rates, whereby the geometry of the plate seems to have an influence.

Clinical relevance: The plate design could have an impact on treatment outcomes of mandibular angle fractures.

Trial registration number: Not applicable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Oral and Maxillofacial Surgery-Heidelberg
Oral and Maxillofacial Surgery-Heidelberg DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.20
自引率
5.60%
发文量
118
期刊介绍: Oral & Maxillofacial Surgery founded as Mund-, Kiefer- und Gesichtschirurgie is a peer-reviewed online journal. It is designed for clinicians as well as researchers.The quarterly journal offers comprehensive coverage of new techniques, important developments and innovative ideas in oral and maxillofacial surgery and interdisciplinary aspects of cranial, facial and oral diseases and their management. The journal publishes papers of the highest scientific merit and widest possible scope on work in oral and maxillofacial surgery as well as supporting specialties. Practice-oriented articles help improve the methods used in oral and maxillofacial surgery.Every aspect of oral and maxillofacial surgery is fully covered through a range of invited review articles, clinical and research articles, technical notes, abstracts, and case reports. Specific topics are: aesthetic facial surgery, clinical pathology, computer-assisted surgery, congenital and craniofacial deformities, dentoalveolar surgery, head and neck oncology, implant dentistry, oral medicine, orthognathic surgery, reconstructive surgery, skull base surgery, TMJ and trauma.Time-limited reviewing and electronic processing allow to publish articles as fast as possible. Accepted articles are rapidly accessible online.Clinical studies submitted for publication have to include a declaration that they have been approved by an ethical committee according to the World Medical Association Declaration of Helsinki 1964 (last amendment during the 52nd World Medical Association General Assembly, Edinburgh, Scotland, October 2000). Experimental animal studies have to be carried out according to the principles of laboratory animal care (NIH publication No 86-23, revised 1985).
期刊最新文献
Correction to: Mapping trends in preemptive analgesia related to oral surgery with the use of Ibuprofen: a comprehensive quantitative and qualitative analysis of bibliometric parameters. Correction to: Acute orbital compartment syndrome due to traumatic hemorrhage: 4-year case series and relevant literature review with emphasis on its management. Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement - an in vitro study. Clinical results of two different three-dimensional plate types for the treatment of mandibular angle fractures: a retrospective analysis. Clinicopathologic and imaging features of odontogenic myxomas: a multi-institutional study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1