{"title":"创新的解决方案还是令人担忧的原因?连续血糖监测仪在非糖尿病患者中的使用:叙述性综述。","authors":"Zhanna Oganesova, John Pemberton, Adrian Brown","doi":"10.1111/dme.15369","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Aims</h3>\n \n <p>Continuous glucose monitors (CGMs) have expanded their scope beyond indicated uses for diabetes management and are gaining traction among people not living with diabetes (PNLD). CGMs track in time glucose levels and are proposed as tools for the early detection of abnormal glucose and a potential solution for its normalisation through behavioural change, particularly, diet personalisation and motivation of physical activity. This becomes relevance given the growing incidence of metabolic conditions, such as type 2 diabetes mellitus (T2DM). Clinical guidelines, however, do not recommend CGMs in contexts outside type 1 diabetes (T1DM) or insulin-treated T2DM. Therefore, there is a visible disconnect between the indicated and real-world usage of these medical devices. While the commercial market for CGMs in PNLD is expanding rapidly, a comprehensive and evidence-based evaluation of the devices' utility in this population has not been done. Therefore, this review aims to formulate a working model for CGM utility in PNLD as proposed by the ‘health and wellness’ market that advertises and distributes it to these individuals.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We aim to critically analyse the available research addressing components of the working model, that is (1) detection of abnormal glucose; (2) behavioural change, and (3) metabolic health improvement.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>We find a lack of consistent and high-quality evidence to support the utility of CGMs for these purposes. We identify significantly under-reserved areas including clinical benchmarks and scoring procedures for CGM measures, device acceptability, and potential adverse effects of CGMs on eating habits in PNLD. We also raise concerns about the robustness of available CGM research.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>In the face of these research gaps, we urge for the commercial claims suggesting the utility of the device in PNLD to be labelled as misleading. We argue that there is a regulatory inadequacy that fuels ‘off-label’ CGM distribution and calls for the strengthening of post-market clinical follow-up oversight for CGMs. We hope this will help to avert the continued misinformation risk to PNLD and ‘off-label’ exacerbation of health disparities.</p>\n </section>\n </div>","PeriodicalId":11251,"journal":{"name":"Diabetic Medicine","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/dme.15369","citationCount":"0","resultStr":"{\"title\":\"Innovative solution or cause for concern? The use of continuous glucose monitors in people not living with diabetes: A narrative review\",\"authors\":\"Zhanna Oganesova, John Pemberton, Adrian Brown\",\"doi\":\"10.1111/dme.15369\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Aims</h3>\\n \\n <p>Continuous glucose monitors (CGMs) have expanded their scope beyond indicated uses for diabetes management and are gaining traction among people not living with diabetes (PNLD). CGMs track in time glucose levels and are proposed as tools for the early detection of abnormal glucose and a potential solution for its normalisation through behavioural change, particularly, diet personalisation and motivation of physical activity. This becomes relevance given the growing incidence of metabolic conditions, such as type 2 diabetes mellitus (T2DM). Clinical guidelines, however, do not recommend CGMs in contexts outside type 1 diabetes (T1DM) or insulin-treated T2DM. Therefore, there is a visible disconnect between the indicated and real-world usage of these medical devices. While the commercial market for CGMs in PNLD is expanding rapidly, a comprehensive and evidence-based evaluation of the devices' utility in this population has not been done. Therefore, this review aims to formulate a working model for CGM utility in PNLD as proposed by the ‘health and wellness’ market that advertises and distributes it to these individuals.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We aim to critically analyse the available research addressing components of the working model, that is (1) detection of abnormal glucose; (2) behavioural change, and (3) metabolic health improvement.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>We find a lack of consistent and high-quality evidence to support the utility of CGMs for these purposes. We identify significantly under-reserved areas including clinical benchmarks and scoring procedures for CGM measures, device acceptability, and potential adverse effects of CGMs on eating habits in PNLD. We also raise concerns about the robustness of available CGM research.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>In the face of these research gaps, we urge for the commercial claims suggesting the utility of the device in PNLD to be labelled as misleading. We argue that there is a regulatory inadequacy that fuels ‘off-label’ CGM distribution and calls for the strengthening of post-market clinical follow-up oversight for CGMs. We hope this will help to avert the continued misinformation risk to PNLD and ‘off-label’ exacerbation of health disparities.</p>\\n </section>\\n </div>\",\"PeriodicalId\":11251,\"journal\":{\"name\":\"Diabetic Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/dme.15369\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetic Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/dme.15369\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetic Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/dme.15369","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Innovative solution or cause for concern? The use of continuous glucose monitors in people not living with diabetes: A narrative review
Aims
Continuous glucose monitors (CGMs) have expanded their scope beyond indicated uses for diabetes management and are gaining traction among people not living with diabetes (PNLD). CGMs track in time glucose levels and are proposed as tools for the early detection of abnormal glucose and a potential solution for its normalisation through behavioural change, particularly, diet personalisation and motivation of physical activity. This becomes relevance given the growing incidence of metabolic conditions, such as type 2 diabetes mellitus (T2DM). Clinical guidelines, however, do not recommend CGMs in contexts outside type 1 diabetes (T1DM) or insulin-treated T2DM. Therefore, there is a visible disconnect between the indicated and real-world usage of these medical devices. While the commercial market for CGMs in PNLD is expanding rapidly, a comprehensive and evidence-based evaluation of the devices' utility in this population has not been done. Therefore, this review aims to formulate a working model for CGM utility in PNLD as proposed by the ‘health and wellness’ market that advertises and distributes it to these individuals.
Methods
We aim to critically analyse the available research addressing components of the working model, that is (1) detection of abnormal glucose; (2) behavioural change, and (3) metabolic health improvement.
Results
We find a lack of consistent and high-quality evidence to support the utility of CGMs for these purposes. We identify significantly under-reserved areas including clinical benchmarks and scoring procedures for CGM measures, device acceptability, and potential adverse effects of CGMs on eating habits in PNLD. We also raise concerns about the robustness of available CGM research.
Conclusion
In the face of these research gaps, we urge for the commercial claims suggesting the utility of the device in PNLD to be labelled as misleading. We argue that there is a regulatory inadequacy that fuels ‘off-label’ CGM distribution and calls for the strengthening of post-market clinical follow-up oversight for CGMs. We hope this will help to avert the continued misinformation risk to PNLD and ‘off-label’ exacerbation of health disparities.
期刊介绍:
Diabetic Medicine, the official journal of Diabetes UK, is published monthly simultaneously, in print and online editions.
The journal publishes a range of key information on all clinical aspects of diabetes mellitus, ranging from human genetic studies through clinical physiology and trials to diabetes epidemiology. We do not publish original animal or cell culture studies unless they are part of a study of clinical diabetes involving humans. Categories of publication include research articles, reviews, editorials, commentaries, and correspondence. All material is peer-reviewed.
We aim to disseminate knowledge about diabetes research with the goal of improving the management of people with diabetes. The journal therefore seeks to provide a forum for the exchange of ideas between clinicians and researchers worldwide. Topics covered are of importance to all healthcare professionals working with people with diabetes, whether in primary care or specialist services.
Surplus generated from the sale of Diabetic Medicine is used by Diabetes UK to know diabetes better and fight diabetes more effectively on behalf of all people affected by and at risk of diabetes as well as their families and carers.”