{"title":"不同的腰髂固定和骶骨斜度对 Tile C1.3 骨盆骨折的影响:一项生物力学研究。","authors":"Shicai Fan, Hongjie Luo, Sheqiang Chen, Haibo Xiang, Qiguang Mai, Zhenhua Zhu, Yuhui Chen, Zhiyong Hou, Wei Chen, Qingan Zhu, Yingze Zhang","doi":"10.1186/s10195-024-00776-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Lumbar-iliac fixation (LIF) is a common treatment for Tile C1.3 pelvic fractures, but different techniques, including L4-L5/L5 unilateral LIF (L4-L5/L5 ULIF), bilateral LIF (BLIF), and L4-L5/L5 triangular osteosynthesis (L4-L5/L5 TOS), still lack biomechanical evaluation. The sacral slope (SS) is key to the vertical shear of the sacrum but has not been investigated for its biomechanical role in lumbar-iliac fixation. The aim of this study is to evaluate the biomechanical effects of different LIF and SS on Tile C1.3 pelvic fracture under two-legged standing load in human cadavers.</p><p><strong>Methods: </strong>Eight male fresh-frozen human lumbar-pelvic specimens were used in this study. Compressive force of 500 N was applied to the L4 vertebrae in the two-legged standing position of the pelvis. The Tile C1.3 pelvic fracture was prepared, and the posterior pelvic ring was fixed with L5 ULIF, L4-L5 ULIF, L5 TOS, L4-L5 TOS, and L4-L5 BLIF, respectively. Displacement and rotation of the anterior S1 foramen at 30° and 40° sacral slope (SS) were analyzed.</p><p><strong>Results: </strong>The displacement of L4-L5/L5 TOS in the left-right and vertical direction, total displacement, and rotation in lateral bending decreased significantly, which is more pronounced at 40° SS. The difference in stability between L4-L5 and L5 ULIF was not significant. BLIF significantly limited left-right displacement. The ULIF vertical displacement at 40° SS was significantly higher than that at 30° SS.</p><p><strong>Conclusions: </strong>This study developed an in vitro two-legged standing pelvic model and demonstrated that TOS enhanced pelvic stability in the coronal plane and cephalad-caudal direction, and BLIF enhanced stability in the left-right direction. L4-L5 ULIF did not further improve the immediate stability, whereas TOS is required to increase the vertical stability at greater SS.</p>","PeriodicalId":48603,"journal":{"name":"Journal of Orthopaedics and Traumatology","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11208344/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of different lumbar-iliac fixation and sacral slope for Tile C1.3 pelvic fractures: a biomechanical study.\",\"authors\":\"Shicai Fan, Hongjie Luo, Sheqiang Chen, Haibo Xiang, Qiguang Mai, Zhenhua Zhu, Yuhui Chen, Zhiyong Hou, Wei Chen, Qingan Zhu, Yingze Zhang\",\"doi\":\"10.1186/s10195-024-00776-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Lumbar-iliac fixation (LIF) is a common treatment for Tile C1.3 pelvic fractures, but different techniques, including L4-L5/L5 unilateral LIF (L4-L5/L5 ULIF), bilateral LIF (BLIF), and L4-L5/L5 triangular osteosynthesis (L4-L5/L5 TOS), still lack biomechanical evaluation. The sacral slope (SS) is key to the vertical shear of the sacrum but has not been investigated for its biomechanical role in lumbar-iliac fixation. The aim of this study is to evaluate the biomechanical effects of different LIF and SS on Tile C1.3 pelvic fracture under two-legged standing load in human cadavers.</p><p><strong>Methods: </strong>Eight male fresh-frozen human lumbar-pelvic specimens were used in this study. Compressive force of 500 N was applied to the L4 vertebrae in the two-legged standing position of the pelvis. The Tile C1.3 pelvic fracture was prepared, and the posterior pelvic ring was fixed with L5 ULIF, L4-L5 ULIF, L5 TOS, L4-L5 TOS, and L4-L5 BLIF, respectively. Displacement and rotation of the anterior S1 foramen at 30° and 40° sacral slope (SS) were analyzed.</p><p><strong>Results: </strong>The displacement of L4-L5/L5 TOS in the left-right and vertical direction, total displacement, and rotation in lateral bending decreased significantly, which is more pronounced at 40° SS. The difference in stability between L4-L5 and L5 ULIF was not significant. BLIF significantly limited left-right displacement. The ULIF vertical displacement at 40° SS was significantly higher than that at 30° SS.</p><p><strong>Conclusions: </strong>This study developed an in vitro two-legged standing pelvic model and demonstrated that TOS enhanced pelvic stability in the coronal plane and cephalad-caudal direction, and BLIF enhanced stability in the left-right direction. L4-L5 ULIF did not further improve the immediate stability, whereas TOS is required to increase the vertical stability at greater SS.</p>\",\"PeriodicalId\":48603,\"journal\":{\"name\":\"Journal of Orthopaedics and Traumatology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11208344/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedics and Traumatology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s10195-024-00776-0\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedics and Traumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s10195-024-00776-0","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
背景:腰髂固定术(LIF)是治疗Tile C1.3骨盆骨折的常用方法,但包括L4-L5/L5单侧LIF(L4-L5/L5 ULIF)、双侧LIF(BLIF)和L4-L5/L5三角骨合成术(L4-L5/L5 TOS)在内的不同技术仍缺乏生物力学评估。骶骨斜坡(SS)是骶骨垂直剪切力的关键,但尚未对其在腰髂固定中的生物力学作用进行研究。本研究旨在评估不同 LIF 和 SS 在人体尸体两腿站立负荷下对 Tile C1.3 骨盆骨折的生物力学影响:方法:本研究使用了 8 具男性新鲜冷冻人体腰椎骨盆标本。在骨盆两腿站立姿势下,对 L4 椎体施加 500 N 的压缩力。制备 Tile C1.3 骨盆骨折,并分别用 L5 ULIF、L4-L5 ULIF、L5 TOS、L4-L5 TOS 和 L4-L5 BLIF 固定骨盆后环。分析了骶骨斜度(SS)为30°和40°时S1前孔的移位和旋转情况:结果:L4-L5/L5 TOS在左右方向和垂直方向的位移、总位移和侧弯时的旋转均明显减少,在骶骨斜度为40°时更为明显。L4-L5 和 L5 ULIF 的稳定性差异不明显。BLIF 明显限制了左右位移。40°SS时的ULIF垂直位移明显高于30°SS时:本研究建立了一个体外双腿站立骨盆模型,并证明TOS可增强骨盆在冠状面和头尾方向的稳定性,而BLIF可增强左右方向的稳定性。L4-L5 ULIF 不能进一步提高即时稳定性,而 TOS 则需要在更大的 SS 上提高垂直稳定性。
Effect of different lumbar-iliac fixation and sacral slope for Tile C1.3 pelvic fractures: a biomechanical study.
Background: Lumbar-iliac fixation (LIF) is a common treatment for Tile C1.3 pelvic fractures, but different techniques, including L4-L5/L5 unilateral LIF (L4-L5/L5 ULIF), bilateral LIF (BLIF), and L4-L5/L5 triangular osteosynthesis (L4-L5/L5 TOS), still lack biomechanical evaluation. The sacral slope (SS) is key to the vertical shear of the sacrum but has not been investigated for its biomechanical role in lumbar-iliac fixation. The aim of this study is to evaluate the biomechanical effects of different LIF and SS on Tile C1.3 pelvic fracture under two-legged standing load in human cadavers.
Methods: Eight male fresh-frozen human lumbar-pelvic specimens were used in this study. Compressive force of 500 N was applied to the L4 vertebrae in the two-legged standing position of the pelvis. The Tile C1.3 pelvic fracture was prepared, and the posterior pelvic ring was fixed with L5 ULIF, L4-L5 ULIF, L5 TOS, L4-L5 TOS, and L4-L5 BLIF, respectively. Displacement and rotation of the anterior S1 foramen at 30° and 40° sacral slope (SS) were analyzed.
Results: The displacement of L4-L5/L5 TOS in the left-right and vertical direction, total displacement, and rotation in lateral bending decreased significantly, which is more pronounced at 40° SS. The difference in stability between L4-L5 and L5 ULIF was not significant. BLIF significantly limited left-right displacement. The ULIF vertical displacement at 40° SS was significantly higher than that at 30° SS.
Conclusions: This study developed an in vitro two-legged standing pelvic model and demonstrated that TOS enhanced pelvic stability in the coronal plane and cephalad-caudal direction, and BLIF enhanced stability in the left-right direction. L4-L5 ULIF did not further improve the immediate stability, whereas TOS is required to increase the vertical stability at greater SS.
期刊介绍:
The Journal of Orthopaedics and Traumatology, the official open access peer-reviewed journal of the Italian Society of Orthopaedics and Traumatology, publishes original papers reporting basic or clinical research in the field of orthopaedic and traumatologic surgery, as well as systematic reviews, brief communications, case reports and letters to the Editor. Narrative instructional reviews and commentaries to original articles may be commissioned by Editors from eminent colleagues. The Journal of Orthopaedics and Traumatology aims to be an international forum for the communication and exchange of ideas concerning the various aspects of orthopaedics and musculoskeletal trauma.