Emma Wikberg, Martijn van Essen, Tobias Rydén, Johanna Svensson, Peter Gjertsson, Peter Bernhardt
{"title":"利用深度学习生成的合成投影进行重建,从稀疏获取的投影中改进 177Lu SPECT 图像。","authors":"Emma Wikberg, Martijn van Essen, Tobias Rydén, Johanna Svensson, Peter Gjertsson, Peter Bernhardt","doi":"10.1186/s40658-024-00655-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>For dosimetry, the demand for whole-body SPECT/CT imaging, which require long acquisition durations with dual-head Anger cameras, is increasing. Here we evaluated sparsely acquired projections and assessed whether the addition of deep-learning-generated synthetic intermediate projections (SIPs) could improve the image quality while preserving dosimetric accuracy.</p><p><strong>Methods: </strong>This study included 16 patients treated with <sup>177</sup>Lu-DOTATATE with SPECT/CT imaging (120 projections, 120P) at four time points. Deep neural networks (CUSIPs) were designed and trained to compile 90 SIPs from 30 acquired projections (30P). The 120P, 30P, and three different CUSIP sets (30P + 90 SIPs) were reconstructed using Monte Carlo-based OSEM reconstruction (yielding 120P_rec, 30P_rec, and CUSIP_recs). The noise levels were visually compared. Quantitative measures of normalised root mean square error, normalised mean absolute error, peak signal-to-noise ratio, and structural similarity were evaluated, and kidney and bone marrow absorbed doses were estimated for each reconstruction set.</p><p><strong>Results: </strong>The use of SIPs visually improved noise levels. All quantitative measures demonstrated high similarity between CUSIP sets and 120P. Linear regression showed nearly perfect concordance of the kidney and bone marrow absorbed doses for all reconstruction sets, compared to the doses of 120P_rec (R<sup>2</sup> ≥ 0.97). Compared to 120P_rec, the mean relative difference in kidney absorbed dose, for all reconstruction sets, was within 3%. For bone marrow absorbed doses, there was a higher dissipation in relative differences, and CUSIP_recs outperformed 30P_rec in mean relative difference (within 4% compared to 9%). Kidney and bone marrow absorbed doses for 30P_rec were statistically significantly different from those of 120_rec, as opposed to the absorbed doses of the best performing CUSIP_rec, where no statistically significant difference was found.</p><p><strong>Conclusion: </strong>When performing SPECT/CT reconstruction, the use of SIPs can substantially reduce acquisition durations in SPECT/CT imaging, enabling acquisition of multiple fields of view of high image quality with satisfactory dosimetric accuracy.</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":"11 1","pages":"53"},"PeriodicalIF":3.0000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11213840/pdf/","citationCount":"0","resultStr":"{\"title\":\"Improvements of <sup>177</sup>Lu SPECT images from sparsely acquired projections by reconstruction with deep-learning-generated synthetic projections.\",\"authors\":\"Emma Wikberg, Martijn van Essen, Tobias Rydén, Johanna Svensson, Peter Gjertsson, Peter Bernhardt\",\"doi\":\"10.1186/s40658-024-00655-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>For dosimetry, the demand for whole-body SPECT/CT imaging, which require long acquisition durations with dual-head Anger cameras, is increasing. Here we evaluated sparsely acquired projections and assessed whether the addition of deep-learning-generated synthetic intermediate projections (SIPs) could improve the image quality while preserving dosimetric accuracy.</p><p><strong>Methods: </strong>This study included 16 patients treated with <sup>177</sup>Lu-DOTATATE with SPECT/CT imaging (120 projections, 120P) at four time points. Deep neural networks (CUSIPs) were designed and trained to compile 90 SIPs from 30 acquired projections (30P). The 120P, 30P, and three different CUSIP sets (30P + 90 SIPs) were reconstructed using Monte Carlo-based OSEM reconstruction (yielding 120P_rec, 30P_rec, and CUSIP_recs). The noise levels were visually compared. Quantitative measures of normalised root mean square error, normalised mean absolute error, peak signal-to-noise ratio, and structural similarity were evaluated, and kidney and bone marrow absorbed doses were estimated for each reconstruction set.</p><p><strong>Results: </strong>The use of SIPs visually improved noise levels. All quantitative measures demonstrated high similarity between CUSIP sets and 120P. Linear regression showed nearly perfect concordance of the kidney and bone marrow absorbed doses for all reconstruction sets, compared to the doses of 120P_rec (R<sup>2</sup> ≥ 0.97). Compared to 120P_rec, the mean relative difference in kidney absorbed dose, for all reconstruction sets, was within 3%. For bone marrow absorbed doses, there was a higher dissipation in relative differences, and CUSIP_recs outperformed 30P_rec in mean relative difference (within 4% compared to 9%). Kidney and bone marrow absorbed doses for 30P_rec were statistically significantly different from those of 120_rec, as opposed to the absorbed doses of the best performing CUSIP_rec, where no statistically significant difference was found.</p><p><strong>Conclusion: </strong>When performing SPECT/CT reconstruction, the use of SIPs can substantially reduce acquisition durations in SPECT/CT imaging, enabling acquisition of multiple fields of view of high image quality with satisfactory dosimetric accuracy.</p>\",\"PeriodicalId\":11559,\"journal\":{\"name\":\"EJNMMI Physics\",\"volume\":\"11 1\",\"pages\":\"53\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11213840/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EJNMMI Physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40658-024-00655-x\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-024-00655-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Improvements of 177Lu SPECT images from sparsely acquired projections by reconstruction with deep-learning-generated synthetic projections.
Background: For dosimetry, the demand for whole-body SPECT/CT imaging, which require long acquisition durations with dual-head Anger cameras, is increasing. Here we evaluated sparsely acquired projections and assessed whether the addition of deep-learning-generated synthetic intermediate projections (SIPs) could improve the image quality while preserving dosimetric accuracy.
Methods: This study included 16 patients treated with 177Lu-DOTATATE with SPECT/CT imaging (120 projections, 120P) at four time points. Deep neural networks (CUSIPs) were designed and trained to compile 90 SIPs from 30 acquired projections (30P). The 120P, 30P, and three different CUSIP sets (30P + 90 SIPs) were reconstructed using Monte Carlo-based OSEM reconstruction (yielding 120P_rec, 30P_rec, and CUSIP_recs). The noise levels were visually compared. Quantitative measures of normalised root mean square error, normalised mean absolute error, peak signal-to-noise ratio, and structural similarity were evaluated, and kidney and bone marrow absorbed doses were estimated for each reconstruction set.
Results: The use of SIPs visually improved noise levels. All quantitative measures demonstrated high similarity between CUSIP sets and 120P. Linear regression showed nearly perfect concordance of the kidney and bone marrow absorbed doses for all reconstruction sets, compared to the doses of 120P_rec (R2 ≥ 0.97). Compared to 120P_rec, the mean relative difference in kidney absorbed dose, for all reconstruction sets, was within 3%. For bone marrow absorbed doses, there was a higher dissipation in relative differences, and CUSIP_recs outperformed 30P_rec in mean relative difference (within 4% compared to 9%). Kidney and bone marrow absorbed doses for 30P_rec were statistically significantly different from those of 120_rec, as opposed to the absorbed doses of the best performing CUSIP_rec, where no statistically significant difference was found.
Conclusion: When performing SPECT/CT reconstruction, the use of SIPs can substantially reduce acquisition durations in SPECT/CT imaging, enabling acquisition of multiple fields of view of high image quality with satisfactory dosimetric accuracy.
期刊介绍:
EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.