牛髋关节模型中移植物宽度和软骨与髋关节交界处保留对唇吸密封完整性的影响。

A E Açan, S Aydemir, G Tukel, M Özcan, R B Hüsemoğlu, O Hapa
{"title":"牛髋关节模型中移植物宽度和软骨与髋关节交界处保留对唇吸密封完整性的影响。","authors":"A E Açan, S Aydemir, G Tukel, M Özcan, R B Hüsemoğlu, O Hapa","doi":"10.26355/eurrev_202406_36459","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study investigates the biomechanical effects of graft width and chondrolabral junction (CLJ) preservation on the labral suction seal in a bovine hip model and aims to validate this model as a practical alternative for hip biomechanical research by comparing it with human cadaver studies.</p><p><strong>Materials and methods: </strong>Twenty hips from two-year-old male bovines were divided into two main groups: CLJ preserved (CLJ+) and CLJ excised (CLJ-). These groups were further divided into eight subgroups: Group 1 with an intact labrum; Group 2 with labrum excision preserving CLJ; Groups 3 and 4 with labral reconstruction on preserved CLJ using 4.5 mm and 9 mm grafts, respectively; Group 5 with a labral tear at 12 to 3 o'clock position without CLJ preservation; Group 6 with complete labrum excision without CLJ preservation; and Groups 7 and 8 with labral reconstruction on excised CLJ using 4.5 mm and 9 mm grafts. Mechanical tests measuring compression and distraction forces were conducted, recording force-displacement values.</p><p><strong>Results: </strong>Both CLJ+ and CLJ- groups showed that labrum excision resulted in the lowest distraction forces, emphasizing labral integrity. Notably, reconstruction with 9 mm grafts improved distraction forces more than 4.5 mm grafts (p<0.001). The change in distraction forces from intact to excised stages was nearly significant between CLJ+ and CLJ- groups (Δ Intact-excised: CLJ+ vs. CLJ-: 92 N vs. 105 N, p=0.08). Distraction forces were measured at 206±27 Newtons in the CLJ preserved group and 186±24 Newtons in the resected group.</p><p><strong>Conclusions: </strong>This study demonstrates that increasing the width of the graft, despite being approximately half and a quarter of the native labrum's size, significantly enhances the distraction force in labral reconstruction within a bovine hip model. This improvement is more pronounced than the effects of preserving the CLJ, highlighting the critical role of graft size in maintaining the biomechanical integrity of the labral suction seal.</p>","PeriodicalId":12152,"journal":{"name":"European review for medical and pharmacological sciences","volume":"28 12","pages":"3828-3835"},"PeriodicalIF":3.3000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of graft width and chondrolabral junction preservation on labral suction seal integrity in bovine hip models.\",\"authors\":\"A E Açan, S Aydemir, G Tukel, M Özcan, R B Hüsemoğlu, O Hapa\",\"doi\":\"10.26355/eurrev_202406_36459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study investigates the biomechanical effects of graft width and chondrolabral junction (CLJ) preservation on the labral suction seal in a bovine hip model and aims to validate this model as a practical alternative for hip biomechanical research by comparing it with human cadaver studies.</p><p><strong>Materials and methods: </strong>Twenty hips from two-year-old male bovines were divided into two main groups: CLJ preserved (CLJ+) and CLJ excised (CLJ-). These groups were further divided into eight subgroups: Group 1 with an intact labrum; Group 2 with labrum excision preserving CLJ; Groups 3 and 4 with labral reconstruction on preserved CLJ using 4.5 mm and 9 mm grafts, respectively; Group 5 with a labral tear at 12 to 3 o'clock position without CLJ preservation; Group 6 with complete labrum excision without CLJ preservation; and Groups 7 and 8 with labral reconstruction on excised CLJ using 4.5 mm and 9 mm grafts. Mechanical tests measuring compression and distraction forces were conducted, recording force-displacement values.</p><p><strong>Results: </strong>Both CLJ+ and CLJ- groups showed that labrum excision resulted in the lowest distraction forces, emphasizing labral integrity. Notably, reconstruction with 9 mm grafts improved distraction forces more than 4.5 mm grafts (p<0.001). The change in distraction forces from intact to excised stages was nearly significant between CLJ+ and CLJ- groups (Δ Intact-excised: CLJ+ vs. CLJ-: 92 N vs. 105 N, p=0.08). Distraction forces were measured at 206±27 Newtons in the CLJ preserved group and 186±24 Newtons in the resected group.</p><p><strong>Conclusions: </strong>This study demonstrates that increasing the width of the graft, despite being approximately half and a quarter of the native labrum's size, significantly enhances the distraction force in labral reconstruction within a bovine hip model. This improvement is more pronounced than the effects of preserving the CLJ, highlighting the critical role of graft size in maintaining the biomechanical integrity of the labral suction seal.</p>\",\"PeriodicalId\":12152,\"journal\":{\"name\":\"European review for medical and pharmacological sciences\",\"volume\":\"28 12\",\"pages\":\"3828-3835\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European review for medical and pharmacological sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.26355/eurrev_202406_36459\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European review for medical and pharmacological sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.26355/eurrev_202406_36459","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究调查了牛髋关节模型中移植物宽度和软骨髋关节交界处(CLJ)保留对唇吸密封的生物力学影响,旨在通过与人类尸体研究进行比较,验证该模型作为髋关节生物力学研究的实用替代方案的有效性:将两岁雄性牛的 20 个髋关节分为两大组:保留的 CLJ(CLJ+)和切除的 CLJ(CLJ-)。这两组又分为八个亚组:第 1 组为完整的唇囊,第 2 组为保留 CLJ 的唇囊切除术,第 3 组和第 4 组分别使用 4.5 毫米和 9 毫米移植物在保留的 CLJ 上重建唇囊,第 5 组为唇囊在 12 点至 3 点钟位置撕裂,但未保留 CLJ,第 6 组为未保留 CLJ 的完全唇囊切除术,第 7 组和第 8 组分别使用 4.5 毫米和 9 毫米移植物在切除的 CLJ 上重建唇囊。进行机械测试,测量压缩力和牵拉力,记录力-位移值:结果:CLJ+组和CLJ-组均显示,切除髋臼唇可获得最低的牵张力,这强调了髋臼唇的完整性。值得注意的是,9 毫米移植物重建比 4.5 毫米移植物重建更能提高牵引力(p 结论:该研究表明,增加移植物的宽度能提高牵引力:这项研究表明,尽管移植物的宽度约为原生唇的一半和四分之一,但在牛髋关节模型中,增加移植物的宽度可显著提高唇重建的牵引力。这种改善比保留CLJ的效果更明显,突出了移植物大小在维持唇吸封生物力学完整性方面的关键作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of graft width and chondrolabral junction preservation on labral suction seal integrity in bovine hip models.

Objective: This study investigates the biomechanical effects of graft width and chondrolabral junction (CLJ) preservation on the labral suction seal in a bovine hip model and aims to validate this model as a practical alternative for hip biomechanical research by comparing it with human cadaver studies.

Materials and methods: Twenty hips from two-year-old male bovines were divided into two main groups: CLJ preserved (CLJ+) and CLJ excised (CLJ-). These groups were further divided into eight subgroups: Group 1 with an intact labrum; Group 2 with labrum excision preserving CLJ; Groups 3 and 4 with labral reconstruction on preserved CLJ using 4.5 mm and 9 mm grafts, respectively; Group 5 with a labral tear at 12 to 3 o'clock position without CLJ preservation; Group 6 with complete labrum excision without CLJ preservation; and Groups 7 and 8 with labral reconstruction on excised CLJ using 4.5 mm and 9 mm grafts. Mechanical tests measuring compression and distraction forces were conducted, recording force-displacement values.

Results: Both CLJ+ and CLJ- groups showed that labrum excision resulted in the lowest distraction forces, emphasizing labral integrity. Notably, reconstruction with 9 mm grafts improved distraction forces more than 4.5 mm grafts (p<0.001). The change in distraction forces from intact to excised stages was nearly significant between CLJ+ and CLJ- groups (Δ Intact-excised: CLJ+ vs. CLJ-: 92 N vs. 105 N, p=0.08). Distraction forces were measured at 206±27 Newtons in the CLJ preserved group and 186±24 Newtons in the resected group.

Conclusions: This study demonstrates that increasing the width of the graft, despite being approximately half and a quarter of the native labrum's size, significantly enhances the distraction force in labral reconstruction within a bovine hip model. This improvement is more pronounced than the effects of preserving the CLJ, highlighting the critical role of graft size in maintaining the biomechanical integrity of the labral suction seal.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
6.10%
发文量
906
审稿时长
2-4 weeks
期刊介绍: European Review for Medical and Pharmacological Sciences, a fortnightly journal, acts as an information exchange tool on several aspects of medical and pharmacological sciences. It publishes reviews, original articles, and results from original research. The purposes of the Journal are to encourage interdisciplinary discussions and to contribute to the advancement of medicine. European Review for Medical and Pharmacological Sciences includes: -Editorials- Reviews- Original articles- Trials- Brief communications- Case reports (only if of particular interest and accompanied by a short review)
期刊最新文献
Comparison of regimens targeting complete remission in the first-line treatment of acute myeloid leukemia patients. Diuretic activity of ethanolic extract and fraction enriched in saponins from Solanum sisymbriifolium Lam. root in rats. Evaluation of adropin level and insulin resistance in non-alcoholic fatty liver patients: a meta-analysis of studies. The possible role of serum NGAL and MMP-9 in the assessment of kidney impairment and cardiovascular risk in children and adolescents with type 1 diabetes mellitus or obesity. Exploring factors influencing COVID-19 severity: a matched case-control study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1