{"title":"在糖尿病和高出血风险患者的毛细血管血液采样中使用激光和传统静脉穿刺器的比较。","authors":"Min Jeong Park, Soon Young Hwang, Ahreum Jang, Soo Yeon Jang, Eyun Song, So Young Park, Da Young Lee, Jaeyoung Kim, Byung Cheol Park, Ji Hee Yu, Ji A Seo, Kyung Mook Choi, Sei Hyun Baik, Hye Jin Yoo, Nan Hee Kim","doi":"10.1007/s10103-024-04128-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Despite the importance of self-monitoring blood glucose (SMBG) for management of diabetes mellitus (DM), frequent blood sampling is discouraged by bleeding risk due to dual-antiplatelet agent therapy (DAPT) or thrombocytopenia.</p><p><strong>Methods: </strong>We compared the bleeding time (BT) of sampling by using a laser-lancing-device (LMT-1000) and a conventional lancet in patients with DM and thrombocytopenia or patients undergoing DAPT. BT was measured using the Duke method, and pain and satisfaction scores were assessed using numeric rating scale (NRS) and visual analog scale (VAS). The consistency in the values of glucose and glycated-hemoglobin (HbA1c) sampled using the LMT-1000 or lancet were compared.</p><p><strong>Results: </strong>The BT of sampling with the LMT-1000 was shorter than that with the lancet in patients with thrombocytopenia (60s vs. 85s, P = 0.024). The NRS was lower and the VAS was higher in laser-applied-sampling than lancet-applied sampling in the DAPT-user group (NRS: 1 vs. 2, P = 0.010; VAS: 7 vs. 6, P = 0.003), whereas the group with thrombocytopenia only showed improvement in the VAS score (8 vs. 7, P = 0.049). Glucose and HbA1c sampled by the LMT-1000 and lancet were significantly correlated in both the DAPT-user and the thrombocytopenia groups.</p><p><strong>Conclusion: </strong>The LMT-1000 can promote SMBG by shortening BT in subject with thrombocytopenia and by increasing satisfaction score, as well as by showing reliable glucose and HbA1c value.</p>","PeriodicalId":17978,"journal":{"name":"Lasers in Medical Science","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk.\",\"authors\":\"Min Jeong Park, Soon Young Hwang, Ahreum Jang, Soo Yeon Jang, Eyun Song, So Young Park, Da Young Lee, Jaeyoung Kim, Byung Cheol Park, Ji Hee Yu, Ji A Seo, Kyung Mook Choi, Sei Hyun Baik, Hye Jin Yoo, Nan Hee Kim\",\"doi\":\"10.1007/s10103-024-04128-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Despite the importance of self-monitoring blood glucose (SMBG) for management of diabetes mellitus (DM), frequent blood sampling is discouraged by bleeding risk due to dual-antiplatelet agent therapy (DAPT) or thrombocytopenia.</p><p><strong>Methods: </strong>We compared the bleeding time (BT) of sampling by using a laser-lancing-device (LMT-1000) and a conventional lancet in patients with DM and thrombocytopenia or patients undergoing DAPT. BT was measured using the Duke method, and pain and satisfaction scores were assessed using numeric rating scale (NRS) and visual analog scale (VAS). The consistency in the values of glucose and glycated-hemoglobin (HbA1c) sampled using the LMT-1000 or lancet were compared.</p><p><strong>Results: </strong>The BT of sampling with the LMT-1000 was shorter than that with the lancet in patients with thrombocytopenia (60s vs. 85s, P = 0.024). The NRS was lower and the VAS was higher in laser-applied-sampling than lancet-applied sampling in the DAPT-user group (NRS: 1 vs. 2, P = 0.010; VAS: 7 vs. 6, P = 0.003), whereas the group with thrombocytopenia only showed improvement in the VAS score (8 vs. 7, P = 0.049). Glucose and HbA1c sampled by the LMT-1000 and lancet were significantly correlated in both the DAPT-user and the thrombocytopenia groups.</p><p><strong>Conclusion: </strong>The LMT-1000 can promote SMBG by shortening BT in subject with thrombocytopenia and by increasing satisfaction score, as well as by showing reliable glucose and HbA1c value.</p>\",\"PeriodicalId\":17978,\"journal\":{\"name\":\"Lasers in Medical Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lasers in Medical Science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10103-024-04128-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lasers in Medical Science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10103-024-04128-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:尽管自我血糖监测(SMBG)对糖尿病(DM)的管理非常重要,但由于双抗血小板药物治疗(DAPT)或血小板减少症导致的出血风险,人们不鼓励频繁采血:我们比较了糖尿病和血小板减少症患者或接受 DAPT 治疗的患者使用激光划线设备(LMT-1000)和传统划线针采血的出血时间(BT)。BT 采用杜克法进行测量,疼痛和满意度评分采用数字评分法(NRS)和视觉模拟评分法(VAS)进行评估。比较了使用 LMT-1000 或柳叶刀采样的葡萄糖和糖化血红蛋白(HbA1c)值的一致性:结果:在血小板减少症患者中,使用 LMT-1000 取样的 BT 比使用柳叶刀取样的 BT 短(60 秒对 85 秒,P = 0.024)。在使用 DAPT 的患者组中,激光采样的 NRS 比使用柳叶刀采样的低,VAS 比使用柳叶刀采样的高(NRS:1 对 2,P=0.010;VAS:7 对 6,P=0.003),而血小板减少症患者组仅在 VAS 评分方面有所改善(8 对 7,P=0.049)。使用 LMT-1000 和柳叶刀采样的葡萄糖和 HbA1c 在 DAPT 使用者组和血小板减少症组都有显著相关性:结论:LMT-1000 可缩短血小板减少症患者的 BT 时间,提高满意度评分,并显示可靠的血糖和 HbA1c 值,从而促进 SMBG 的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk.

Purpose: Despite the importance of self-monitoring blood glucose (SMBG) for management of diabetes mellitus (DM), frequent blood sampling is discouraged by bleeding risk due to dual-antiplatelet agent therapy (DAPT) or thrombocytopenia.

Methods: We compared the bleeding time (BT) of sampling by using a laser-lancing-device (LMT-1000) and a conventional lancet in patients with DM and thrombocytopenia or patients undergoing DAPT. BT was measured using the Duke method, and pain and satisfaction scores were assessed using numeric rating scale (NRS) and visual analog scale (VAS). The consistency in the values of glucose and glycated-hemoglobin (HbA1c) sampled using the LMT-1000 or lancet were compared.

Results: The BT of sampling with the LMT-1000 was shorter than that with the lancet in patients with thrombocytopenia (60s vs. 85s, P = 0.024). The NRS was lower and the VAS was higher in laser-applied-sampling than lancet-applied sampling in the DAPT-user group (NRS: 1 vs. 2, P = 0.010; VAS: 7 vs. 6, P = 0.003), whereas the group with thrombocytopenia only showed improvement in the VAS score (8 vs. 7, P = 0.049). Glucose and HbA1c sampled by the LMT-1000 and lancet were significantly correlated in both the DAPT-user and the thrombocytopenia groups.

Conclusion: The LMT-1000 can promote SMBG by shortening BT in subject with thrombocytopenia and by increasing satisfaction score, as well as by showing reliable glucose and HbA1c value.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lasers in Medical Science
Lasers in Medical Science 医学-工程:生物医学
CiteScore
4.50
自引率
4.80%
发文量
192
审稿时长
3-8 weeks
期刊介绍: Lasers in Medical Science (LIMS) has established itself as the leading international journal in the rapidly expanding field of medical and dental applications of lasers and light. It provides a forum for the publication of papers on the technical, experimental, and clinical aspects of the use of medical lasers, including lasers in surgery, endoscopy, angioplasty, hyperthermia of tumors, and photodynamic therapy. In addition to medical laser applications, LIMS presents high-quality manuscripts on a wide range of dental topics, including aesthetic dentistry, endodontics, orthodontics, and prosthodontics. The journal publishes articles on the medical and dental applications of novel laser technologies, light delivery systems, sensors to monitor laser effects, basic laser-tissue interactions, and the modeling of laser-tissue interactions. Beyond laser applications, LIMS features articles relating to the use of non-laser light-tissue interactions.
期刊最新文献
Photobiomodulation effects on neuronal transdifferentiation of immortalized adipose-derived mesenchymal stem cells. Antifungal efficacy of photodynamic therapy on Cryptococcus and Candida species is enhanced by Streptomyces spp. extracts in vitro. Optimizing near infrared laser irradiation and photosensitizer accumulation period for indocyanine green-mediated photodynamic therapy in breast cancer xenografts: a focus on treatment and characterization. Photobiomodulation using red and infrared spectrum light emitting-diode (LED) for the healing of diabetic foot ulcers: a controlled randomized clinical trial. Blue light inhibits cell viability and proliferation in hair follicle stem cells and dermal papilla cells.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1