O V Svetlova, I N Koshits, R M Pankratov, O V Makarovskaya, M V Zaseeva
{"title":"[眼压与眼球僵硬度的年龄相关变化之间的关系]。","authors":"O V Svetlova, I N Koshits, R M Pankratov, O V Makarovskaya, M V Zaseeva","doi":"10.17116/oftalma202414003111","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to identify the correlation between age-related fluctuations in the average values of rigidity of the fibrous tunic of the eye (FTE) and corresponding ranges of true intraocular pressure (IOP) in healthy eyes and eyes with open-angle glaucoma (OAG); using the identified ranges of FTE rigidity, to establish the appropriate IOP zones for healthy and glaucomatous eyes, taking into account the aging periods as classified by the World Health Organization (WHO).</p><p><strong>Material and methods: </strong>Ocular-Response Analyzer tonometry was used according to the Koshits-Svetlova dynamic diagnostic method to examine 674 patients with healthy eyes and 518 patients with glaucomatous eyes, aged 18 to 90 years, classified according to the WHO aging periods, and a theoretical analysis was conducted to estimate clinical values of FTE rigidity, the current level of true IOP, and the calculated individual IOP level in a patient's eye during youth.</p><p><strong>Results: </strong>The following IOP level zones were identified for patients with healthy and glaucomatous eyes: low IOP zone (≤13 mm Hg); medium IOP zone (14-20 mm Hg); elevated IOP zone (21-26 mm Hg); high IOP zone (27-32 mm Hg); subcompensated IOP zone (33-39 mm Hg); and decompensated IOP zone (≥40 mm Hg).</p><p><strong>Conclusion: </strong>The fundamental physiological criterion \"rigidity\" does not depend on central corneal thickness and consistently reflects the current level of true IOP. In all examined patients, both with healthy and glaucomatous eyes, healthy and glaucoma eyes with the same level of current rigidity had the same level of IOP. The ability to assign a given healthy or glaucomatous eye to a specific individual IOP zone is particularly important for the polyclinic system.</p>","PeriodicalId":23529,"journal":{"name":"Vestnik oftalmologii","volume":"140 3","pages":"11-18"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The relationship between intraocular pressure and age-related variations in ocular rigidity].\",\"authors\":\"O V Svetlova, I N Koshits, R M Pankratov, O V Makarovskaya, M V Zaseeva\",\"doi\":\"10.17116/oftalma202414003111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to identify the correlation between age-related fluctuations in the average values of rigidity of the fibrous tunic of the eye (FTE) and corresponding ranges of true intraocular pressure (IOP) in healthy eyes and eyes with open-angle glaucoma (OAG); using the identified ranges of FTE rigidity, to establish the appropriate IOP zones for healthy and glaucomatous eyes, taking into account the aging periods as classified by the World Health Organization (WHO).</p><p><strong>Material and methods: </strong>Ocular-Response Analyzer tonometry was used according to the Koshits-Svetlova dynamic diagnostic method to examine 674 patients with healthy eyes and 518 patients with glaucomatous eyes, aged 18 to 90 years, classified according to the WHO aging periods, and a theoretical analysis was conducted to estimate clinical values of FTE rigidity, the current level of true IOP, and the calculated individual IOP level in a patient's eye during youth.</p><p><strong>Results: </strong>The following IOP level zones were identified for patients with healthy and glaucomatous eyes: low IOP zone (≤13 mm Hg); medium IOP zone (14-20 mm Hg); elevated IOP zone (21-26 mm Hg); high IOP zone (27-32 mm Hg); subcompensated IOP zone (33-39 mm Hg); and decompensated IOP zone (≥40 mm Hg).</p><p><strong>Conclusion: </strong>The fundamental physiological criterion \\\"rigidity\\\" does not depend on central corneal thickness and consistently reflects the current level of true IOP. In all examined patients, both with healthy and glaucomatous eyes, healthy and glaucoma eyes with the same level of current rigidity had the same level of IOP. The ability to assign a given healthy or glaucomatous eye to a specific individual IOP zone is particularly important for the polyclinic system.</p>\",\"PeriodicalId\":23529,\"journal\":{\"name\":\"Vestnik oftalmologii\",\"volume\":\"140 3\",\"pages\":\"11-18\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik oftalmologii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17116/oftalma202414003111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik oftalmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/oftalma202414003111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
[The relationship between intraocular pressure and age-related variations in ocular rigidity].
Purpose: This study aimed to identify the correlation between age-related fluctuations in the average values of rigidity of the fibrous tunic of the eye (FTE) and corresponding ranges of true intraocular pressure (IOP) in healthy eyes and eyes with open-angle glaucoma (OAG); using the identified ranges of FTE rigidity, to establish the appropriate IOP zones for healthy and glaucomatous eyes, taking into account the aging periods as classified by the World Health Organization (WHO).
Material and methods: Ocular-Response Analyzer tonometry was used according to the Koshits-Svetlova dynamic diagnostic method to examine 674 patients with healthy eyes and 518 patients with glaucomatous eyes, aged 18 to 90 years, classified according to the WHO aging periods, and a theoretical analysis was conducted to estimate clinical values of FTE rigidity, the current level of true IOP, and the calculated individual IOP level in a patient's eye during youth.
Results: The following IOP level zones were identified for patients with healthy and glaucomatous eyes: low IOP zone (≤13 mm Hg); medium IOP zone (14-20 mm Hg); elevated IOP zone (21-26 mm Hg); high IOP zone (27-32 mm Hg); subcompensated IOP zone (33-39 mm Hg); and decompensated IOP zone (≥40 mm Hg).
Conclusion: The fundamental physiological criterion "rigidity" does not depend on central corneal thickness and consistently reflects the current level of true IOP. In all examined patients, both with healthy and glaucomatous eyes, healthy and glaucoma eyes with the same level of current rigidity had the same level of IOP. The ability to assign a given healthy or glaucomatous eye to a specific individual IOP zone is particularly important for the polyclinic system.
期刊介绍:
The journal publishes materials on the diagnosis and treatment of eye diseases, hygiene of vision, prevention of ophthalmic affections, history of Russian ophthalmology, organization of ophthalmological aid to the population, as well as the problems of special equipment. Original scientific articles and surveys on urgent problems of theory and practice of Russian and foreign ophthalmology are published. The journal contains book reviews on ophthalmology, information on the activities of ophthalmologists" scientific societies, chronicle of congresses and conferences.The journal is intended for ophthalmologists and scientific workers dealing with clinical problems of diseases of the eye and physiology of vision.