改良运动学对齐和引导运动双叉稳定型全膝关节置换术的短期临床效果比较。

IF 2.3 4区 医学 Q2 ORTHOPEDICS Arthroplasty Pub Date : 2024-07-04 DOI:10.1186/s42836-024-00257-z
Kensuke Anjiki, Naoki Nakano, Kazunari Ishida, Koji Takayama, Masahiro Fujita, Tomoyuki Kamenaga, Masanori Tsubosaka, Yuichi Kuroda, Shinya Hayashi, Ryosuke Kuroda, Tomoyuki Matsumoto
{"title":"改良运动学对齐和引导运动双叉稳定型全膝关节置换术的短期临床效果比较。","authors":"Kensuke Anjiki, Naoki Nakano, Kazunari Ishida, Koji Takayama, Masahiro Fujita, Tomoyuki Kamenaga, Masanori Tsubosaka, Yuichi Kuroda, Shinya Hayashi, Ryosuke Kuroda, Tomoyuki Matsumoto","doi":"10.1186/s42836-024-00257-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Both kinematically-aligned (KA) total knee arthroplasty (TKA) and bicruciate stabilized (BCS) TKA aim to reproduce the physiological knee kinematics. In this study, we compared the femoro-tibial component rotational mismatch between patients who underwent modified KA-TKA and those who received guided-motion BCS-TKA, and its influence on the clinical outcomes.</p><p><strong>Methods: </strong>In this retrospective study, 77 consecutive patients were included and divided into two groups: subjects who underwent modified KA-TKA with Persona (KA Group; n = 42) and those who received BCS-TKA with JOURNEY II (BCS group; n = 35). Range of motion, the 2011 Knee Society Score (KSS), the rotational alignment of the femoral and tibial components, and the correlations between the rotational mismatch and the 2011 KSS subscales were examined.</p><p><strong>Results: </strong>The postoperative objective knee indicators (P = 0.0157), patient satisfaction (P = 0.0039) and functional activity scores (P = 0.0013) in the KA group were significantly superior to those in the BCS group 1 year postoperatively. There was no significant difference between the two groups observed in the rotational mismatch. In the BCS group, significant negative correlations were identified between the rotational mismatch and objective indicators, patient satisfaction, and functional activity scores but not in the KA group.</p><p><strong>Conclusions: </strong>The short-term clinical results following KA-TKA showed superior objective knee indicators, patient satisfaction and functional activity scores. A negative correlation was observed between component rotational mismatch and the 2011 KSS subscales in the BCS group, compared to no relationship found between the two in the KA group. These findings suggested that KA-TKA has a relatively higher tolerance for rotational mismatch than BCS-TKA.</p>","PeriodicalId":52831,"journal":{"name":"Arthroplasty","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11223350/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of short-term clinical results between modified kinematically-aligned and guided motion bicruciate stabilized total knee arthroplasty.\",\"authors\":\"Kensuke Anjiki, Naoki Nakano, Kazunari Ishida, Koji Takayama, Masahiro Fujita, Tomoyuki Kamenaga, Masanori Tsubosaka, Yuichi Kuroda, Shinya Hayashi, Ryosuke Kuroda, Tomoyuki Matsumoto\",\"doi\":\"10.1186/s42836-024-00257-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Both kinematically-aligned (KA) total knee arthroplasty (TKA) and bicruciate stabilized (BCS) TKA aim to reproduce the physiological knee kinematics. In this study, we compared the femoro-tibial component rotational mismatch between patients who underwent modified KA-TKA and those who received guided-motion BCS-TKA, and its influence on the clinical outcomes.</p><p><strong>Methods: </strong>In this retrospective study, 77 consecutive patients were included and divided into two groups: subjects who underwent modified KA-TKA with Persona (KA Group; n = 42) and those who received BCS-TKA with JOURNEY II (BCS group; n = 35). Range of motion, the 2011 Knee Society Score (KSS), the rotational alignment of the femoral and tibial components, and the correlations between the rotational mismatch and the 2011 KSS subscales were examined.</p><p><strong>Results: </strong>The postoperative objective knee indicators (P = 0.0157), patient satisfaction (P = 0.0039) and functional activity scores (P = 0.0013) in the KA group were significantly superior to those in the BCS group 1 year postoperatively. There was no significant difference between the two groups observed in the rotational mismatch. In the BCS group, significant negative correlations were identified between the rotational mismatch and objective indicators, patient satisfaction, and functional activity scores but not in the KA group.</p><p><strong>Conclusions: </strong>The short-term clinical results following KA-TKA showed superior objective knee indicators, patient satisfaction and functional activity scores. A negative correlation was observed between component rotational mismatch and the 2011 KSS subscales in the BCS group, compared to no relationship found between the two in the KA group. These findings suggested that KA-TKA has a relatively higher tolerance for rotational mismatch than BCS-TKA.</p>\",\"PeriodicalId\":52831,\"journal\":{\"name\":\"Arthroplasty\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11223350/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arthroplasty\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s42836-024-00257-z\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00257-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:运动学对位(KA)全膝关节置换术(TKA)和双椎体稳定(BCS)TKA都旨在再现膝关节的生理运动学。在这项研究中,我们比较了接受改良 KA-TKA 和接受引导运动 BCS-TKA 患者的股骨-胫骨组件旋转不匹配情况及其对临床结果的影响:在这项回顾性研究中,共纳入了 77 名连续患者,并将其分为两组:接受 Persona 改良 KA-TKA 的受试者(KA 组;n = 42)和接受 JOURNEY II BCS-TKA 的受试者(BCS 组;n = 35)。研究对象包括活动范围、2011年膝关节协会评分(KSS)、股骨和胫骨组件的旋转对位以及旋转错位与2011年KSS分量表之间的相关性:结果:术后1年,KA组的膝关节客观指标(P = 0.0157)、患者满意度(P = 0.0039)和功能活动评分(P = 0.0013)明显优于BCS组。两组在旋转错位方面无明显差异。在BCS组,旋转错位与客观指标、患者满意度和功能活动评分之间存在明显的负相关,而在KA组则没有:结论:KA-TKA术后的短期临床结果显示,膝关节客观指标、患者满意度和功能活动评分均优于BCS组。在 BCS 组中,观察到组件旋转不匹配与 2011 年 KSS 分量表之间存在负相关,而在 KA 组中两者之间没有发现任何关系。这些研究结果表明,与 BCS-TKA 相比,KA-TKA 对旋转不匹配的容忍度相对较高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of short-term clinical results between modified kinematically-aligned and guided motion bicruciate stabilized total knee arthroplasty.

Background: Both kinematically-aligned (KA) total knee arthroplasty (TKA) and bicruciate stabilized (BCS) TKA aim to reproduce the physiological knee kinematics. In this study, we compared the femoro-tibial component rotational mismatch between patients who underwent modified KA-TKA and those who received guided-motion BCS-TKA, and its influence on the clinical outcomes.

Methods: In this retrospective study, 77 consecutive patients were included and divided into two groups: subjects who underwent modified KA-TKA with Persona (KA Group; n = 42) and those who received BCS-TKA with JOURNEY II (BCS group; n = 35). Range of motion, the 2011 Knee Society Score (KSS), the rotational alignment of the femoral and tibial components, and the correlations between the rotational mismatch and the 2011 KSS subscales were examined.

Results: The postoperative objective knee indicators (P = 0.0157), patient satisfaction (P = 0.0039) and functional activity scores (P = 0.0013) in the KA group were significantly superior to those in the BCS group 1 year postoperatively. There was no significant difference between the two groups observed in the rotational mismatch. In the BCS group, significant negative correlations were identified between the rotational mismatch and objective indicators, patient satisfaction, and functional activity scores but not in the KA group.

Conclusions: The short-term clinical results following KA-TKA showed superior objective knee indicators, patient satisfaction and functional activity scores. A negative correlation was observed between component rotational mismatch and the 2011 KSS subscales in the BCS group, compared to no relationship found between the two in the KA group. These findings suggested that KA-TKA has a relatively higher tolerance for rotational mismatch than BCS-TKA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arthroplasty
Arthroplasty ORTHOPEDICS-
CiteScore
2.20
自引率
0.00%
发文量
49
审稿时长
15 weeks
期刊最新文献
A 10-point preoperative checklist: selecting patients for outpatient joint replacement surgery. Comparison of the safety and efficacy of three superficial skin closure methods for multi-layer wound closure in total knee arthroplasty: a multicenter, prospective, randomized controlled trial. Conversion of UKA to TKA using identical standard implants-How does it compare to primary UKA, primary TKA and revision TKA? Reliability of pre-resection ligament tension assessment in imageless robotic assisted total knee replacement. Should we be concerned when the anterior approach to the hip goes accidentally medial? A retrospective study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1