Canoxidin® 用于预防留置导管患者导管结壳的单中心、双盲、随机、安慰剂对照试验研究。

Actas urologicas espanolas Pub Date : 2024-11-01 Epub Date: 2024-07-01 DOI:10.1016/j.acuroe.2024.06.004
{"title":"Canoxidin® 用于预防留置导管患者导管结壳的单中心、双盲、随机、安慰剂对照试验研究。","authors":"","doi":"10.1016/j.acuroe.2024.06.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction and objectives</h3><div>Long-term use of an indwelling catheter is associated with complications such as catheter encrustation and infection. Canoxidin® is a novel oral treatment that can potentially prevent catheter encrustation, as it contains a urine acidifier and a combination of two crystallization inhibitors. This study aimed to evaluate the effects of Canoxidin® on catheter encrustation in patients with indwelling Foley catheters.</div></div><div><h3>Patients and methods</h3><div>This was a single-center, double-blind, randomized, placebo-controlled study. Neuro-urology patients aged ≥18 years with an indwelling catheter (urethral or suprapubic) were randomized to treatment consisting of either Canoxidin® or placebo for one month. Foley catheters (two per patient, one before treatment and one after treatment) were removed for analysis of the presence and degree of encrustation.</div></div><div><h3>Results</h3><div>A total of 40 patients were enrolled and randomized, 28 of whom had analyzable catheters (13 assigned to Canoxidin® and 15 assigned to placebo). The patients had a mean age of 51.8 years, and eight (28.6%) were female. Two patients (13.3%) in the placebo group and eight patients (61.5%) in the Canoxidin® group experienced an improvement (less encrustation). There was a significant association between Canoxidin® and improvement (odds ratio: 10.4, 95% confidence interval: 1.6 to 66.9, P = 0.016). No adverse effects attributable to the treatment were reported.</div></div><div><h3>Conclusions</h3><div>The overall rate of catheter encrustation was high among those with indwelling Foley catheters. One-month treatment with Canoxidin® reduced the formation of these encrustations, with an excellent short-term safety profile.</div></div>","PeriodicalId":94291,"journal":{"name":"Actas urologicas espanolas","volume":"48 9","pages":"Pages 658-664"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-center, double-blind, randomized, placebo-controlled pilot study of Canoxidin® for prevention of catheter encrustation in patients with indwelling catheters\",\"authors\":\"\",\"doi\":\"10.1016/j.acuroe.2024.06.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction and objectives</h3><div>Long-term use of an indwelling catheter is associated with complications such as catheter encrustation and infection. Canoxidin® is a novel oral treatment that can potentially prevent catheter encrustation, as it contains a urine acidifier and a combination of two crystallization inhibitors. This study aimed to evaluate the effects of Canoxidin® on catheter encrustation in patients with indwelling Foley catheters.</div></div><div><h3>Patients and methods</h3><div>This was a single-center, double-blind, randomized, placebo-controlled study. Neuro-urology patients aged ≥18 years with an indwelling catheter (urethral or suprapubic) were randomized to treatment consisting of either Canoxidin® or placebo for one month. Foley catheters (two per patient, one before treatment and one after treatment) were removed for analysis of the presence and degree of encrustation.</div></div><div><h3>Results</h3><div>A total of 40 patients were enrolled and randomized, 28 of whom had analyzable catheters (13 assigned to Canoxidin® and 15 assigned to placebo). The patients had a mean age of 51.8 years, and eight (28.6%) were female. Two patients (13.3%) in the placebo group and eight patients (61.5%) in the Canoxidin® group experienced an improvement (less encrustation). There was a significant association between Canoxidin® and improvement (odds ratio: 10.4, 95% confidence interval: 1.6 to 66.9, P = 0.016). No adverse effects attributable to the treatment were reported.</div></div><div><h3>Conclusions</h3><div>The overall rate of catheter encrustation was high among those with indwelling Foley catheters. One-month treatment with Canoxidin® reduced the formation of these encrustations, with an excellent short-term safety profile.</div></div>\",\"PeriodicalId\":94291,\"journal\":{\"name\":\"Actas urologicas espanolas\",\"volume\":\"48 9\",\"pages\":\"Pages 658-664\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Actas urologicas espanolas\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2173578624000829\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Actas urologicas espanolas","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2173578624000829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导言和目的:长期使用留置导管会导致导管结壳和感染等并发症。Canoxidin® 是一种新型口服治疗药物,含有尿酸化剂和两种结晶抑制剂的组合,有可能预防导管结壳。本研究旨在评估 Canoxidin® 对留置 Foley 导管患者导管结壳的影响:这是一项单中心、双盲、随机、安慰剂对照研究。年龄≥18 岁、留置导尿管(尿道或耻骨上导尿管)的神经泌尿科患者被随机分配接受为期一个月的 Canoxidin® 或安慰剂治疗。每个患者拔出两根导尿管(一根在治疗前,一根在治疗后),以分析是否存在包壳以及包壳的程度:共有 40 名患者参加了随机治疗,其中 28 人的导管可进行分析(13 人被分配使用 Canoxidin®,15 人被分配使用安慰剂)。患者的平均年龄为 51.8 岁,其中 8 人(28.6%)为女性。安慰剂组的两名患者(13.3%)和 Canoxidin® 组的八名患者(61.5%)的病情有所改善(结壳减少)。Canoxidin®与病情改善之间存在明显关联(几率比:10.4,95% 置信区间:1.6 至 66.9,P = 0.016)。结论:Canoxidin®与导管包膜改善之间存在明显关联(几率比:10.4,95% 置信区间:1.6 至 66.9,P = 0.016):结论:在留置福里导管的患者中,导管结壳的总体发生率很高。使用 Canoxidin® 进行为期一个月的治疗可减少这些包壳的形成,而且短期安全性极佳。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Single-center, double-blind, randomized, placebo-controlled pilot study of Canoxidin® for prevention of catheter encrustation in patients with indwelling catheters

Introduction and objectives

Long-term use of an indwelling catheter is associated with complications such as catheter encrustation and infection. Canoxidin® is a novel oral treatment that can potentially prevent catheter encrustation, as it contains a urine acidifier and a combination of two crystallization inhibitors. This study aimed to evaluate the effects of Canoxidin® on catheter encrustation in patients with indwelling Foley catheters.

Patients and methods

This was a single-center, double-blind, randomized, placebo-controlled study. Neuro-urology patients aged ≥18 years with an indwelling catheter (urethral or suprapubic) were randomized to treatment consisting of either Canoxidin® or placebo for one month. Foley catheters (two per patient, one before treatment and one after treatment) were removed for analysis of the presence and degree of encrustation.

Results

A total of 40 patients were enrolled and randomized, 28 of whom had analyzable catheters (13 assigned to Canoxidin® and 15 assigned to placebo). The patients had a mean age of 51.8 years, and eight (28.6%) were female. Two patients (13.3%) in the placebo group and eight patients (61.5%) in the Canoxidin® group experienced an improvement (less encrustation). There was a significant association between Canoxidin® and improvement (odds ratio: 10.4, 95% confidence interval: 1.6 to 66.9, P = 0.016). No adverse effects attributable to the treatment were reported.

Conclusions

The overall rate of catheter encrustation was high among those with indwelling Foley catheters. One-month treatment with Canoxidin® reduced the formation of these encrustations, with an excellent short-term safety profile.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative outcomes of Mini-PCNL and suction-assisted flexible ureteroscopy in patients with renal stones ≥2 cm. Morphometric changes in pelvic floor structure following non-invasive rehabilitation and neuromodulation assessed by ultrasound imaging. Comment on “Profile of patients with clean intermittent catheterization and associated resource consumption. Multicenter study in Spain” Comment on “Analysis of device survival and predictive factors in a cohort of patients undergoing male artificial urinary sphincter implantation” Transference of video game skills to robotic and laparoscopic surgery: Feasibility in contemporary practice
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1