基于白光扫描干涉仪相位误差不敏感方法的精确表面测量

IF 2 3区 材料科学 Q2 ENGINEERING, MECHANICAL Surface Topography: Metrology and Properties Pub Date : 2024-06-07 DOI:10.1088/2051-672x/ad50f0
Changsheng Ji, Songjie Luo, Osami Sasaki, Ziyang Chen, Jixiong Pu
{"title":"基于白光扫描干涉仪相位误差不敏感方法的精确表面测量","authors":"Changsheng Ji, Songjie Luo, Osami Sasaki, Ziyang Chen, Jixiong Pu","doi":"10.1088/2051-672x/ad50f0","DOIUrl":null,"url":null,"abstract":"Phase error induced by the scanning error of piezoelectric transducer and vibration in white-light interference signal (WLIS) impose limitations on measurement accuracy. In this paper, two techniques are investigated to eliminate phase error cooperatively. A monochromatic interferometer owning the same optical path as the white-light scanning interferometer (WLSI) is employed to detect and compensate the phase error. Due to the incomplete consistency between the detected phase error and its actual distribution, an algorithm is introduced to further enhance the measurement accuracy. The simulation is given to prove the proposed method is available in different magnitude of noise. In the experiment, the front surface of wedged window is measured, whose maximum fluctuations are reduced to 28.8 nm and 3.0 nm from 62.7 nm with the gradual application of two technologies, and the repeatability reach 5.0 nm and 0.4 nm from 16.8 nm, respectively. The root mean square height <italic toggle=\"yes\">S</italic>\n<sub>\n<italic toggle=\"yes\">q</italic>\n</sub> and maximum height <italic toggle=\"yes\">S</italic>\n<sub>\n<italic toggle=\"yes\">z</italic>\n</sub> ultimately decrease to 1.3 nm and 1.6 nm. The measurement of step with height of about 3.0 <italic toggle=\"yes\">μ</italic>m also has the good accuracy and repeatability after phase error elimination. Since the different reflectivity of measured surfaces in the wavelength range of light source will also bring the measurement error, its influences are analyzed by simulation. The proposed techniques provide a phase error insensitive method for WLSI that has potential on measurement in the complex environment.","PeriodicalId":22028,"journal":{"name":"Surface Topography: Metrology and Properties","volume":"29 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exact surface measurement based on phase error insensitive method for white-light scanning interferometer\",\"authors\":\"Changsheng Ji, Songjie Luo, Osami Sasaki, Ziyang Chen, Jixiong Pu\",\"doi\":\"10.1088/2051-672x/ad50f0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Phase error induced by the scanning error of piezoelectric transducer and vibration in white-light interference signal (WLIS) impose limitations on measurement accuracy. In this paper, two techniques are investigated to eliminate phase error cooperatively. A monochromatic interferometer owning the same optical path as the white-light scanning interferometer (WLSI) is employed to detect and compensate the phase error. Due to the incomplete consistency between the detected phase error and its actual distribution, an algorithm is introduced to further enhance the measurement accuracy. The simulation is given to prove the proposed method is available in different magnitude of noise. In the experiment, the front surface of wedged window is measured, whose maximum fluctuations are reduced to 28.8 nm and 3.0 nm from 62.7 nm with the gradual application of two technologies, and the repeatability reach 5.0 nm and 0.4 nm from 16.8 nm, respectively. The root mean square height <italic toggle=\\\"yes\\\">S</italic>\\n<sub>\\n<italic toggle=\\\"yes\\\">q</italic>\\n</sub> and maximum height <italic toggle=\\\"yes\\\">S</italic>\\n<sub>\\n<italic toggle=\\\"yes\\\">z</italic>\\n</sub> ultimately decrease to 1.3 nm and 1.6 nm. The measurement of step with height of about 3.0 <italic toggle=\\\"yes\\\">μ</italic>m also has the good accuracy and repeatability after phase error elimination. Since the different reflectivity of measured surfaces in the wavelength range of light source will also bring the measurement error, its influences are analyzed by simulation. The proposed techniques provide a phase error insensitive method for WLSI that has potential on measurement in the complex environment.\",\"PeriodicalId\":22028,\"journal\":{\"name\":\"Surface Topography: Metrology and Properties\",\"volume\":\"29 1\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surface Topography: Metrology and Properties\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1088/2051-672x/ad50f0\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surface Topography: Metrology and Properties","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1088/2051-672x/ad50f0","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

压电传感器的扫描误差和白光干扰信号(WLIS)中的振动引起的相位误差对测量精度造成了限制。本文研究了两种协同消除相位误差的技术。采用与白光扫描干涉仪(WLSI)光路相同的单色干涉仪来检测和补偿相位误差。由于检测到的相位误差与其实际分布不完全一致,因此引入了一种算法来进一步提高测量精度。仿真证明了所提出的方法适用于不同量级的噪声。在实验中,测量了楔形窗口的前表面,随着两种技术的逐步应用,其最大波动分别从 62.7 nm 降至 28.8 nm 和 3.0 nm,重复性分别从 16.8 nm 降至 5.0 nm 和 0.4 nm。均方根高度 Sq 和最大高度 Sz 最终降至 1.3 nm 和 1.6 nm。消除相位误差后,对高度约为 3.0 μm 的台阶的测量也具有良好的精度和重复性。由于被测表面在光源波长范围内的反射率不同,也会带来测量误差,因此对其影响因素进行了模拟分析。所提出的技术为 WLSI 提供了一种对相位误差不敏感的方法,具有在复杂环境中进行测量的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Exact surface measurement based on phase error insensitive method for white-light scanning interferometer
Phase error induced by the scanning error of piezoelectric transducer and vibration in white-light interference signal (WLIS) impose limitations on measurement accuracy. In this paper, two techniques are investigated to eliminate phase error cooperatively. A monochromatic interferometer owning the same optical path as the white-light scanning interferometer (WLSI) is employed to detect and compensate the phase error. Due to the incomplete consistency between the detected phase error and its actual distribution, an algorithm is introduced to further enhance the measurement accuracy. The simulation is given to prove the proposed method is available in different magnitude of noise. In the experiment, the front surface of wedged window is measured, whose maximum fluctuations are reduced to 28.8 nm and 3.0 nm from 62.7 nm with the gradual application of two technologies, and the repeatability reach 5.0 nm and 0.4 nm from 16.8 nm, respectively. The root mean square height S q and maximum height S z ultimately decrease to 1.3 nm and 1.6 nm. The measurement of step with height of about 3.0 μm also has the good accuracy and repeatability after phase error elimination. Since the different reflectivity of measured surfaces in the wavelength range of light source will also bring the measurement error, its influences are analyzed by simulation. The proposed techniques provide a phase error insensitive method for WLSI that has potential on measurement in the complex environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Surface Topography: Metrology and Properties
Surface Topography: Metrology and Properties Materials Science-Materials Chemistry
CiteScore
4.10
自引率
22.20%
发文量
183
期刊介绍: An international forum for academics, industrialists and engineers to publish the latest research in surface topography measurement and characterisation, instrumentation development and the properties of surfaces.
期刊最新文献
The microhardness, morphology and tribological property of TC4 subjected to machine hammer peening Surface profile inspection for large structures with laser scanning Evolution of tooth surface morphology and tribological properties of helical gears during mixed lubrication sliding wear Analysis of co-relation on LPBF process parameter on wear characteristics of Cu-Cr-Zr alloy Influence of titanium carbide particles on the characteristics of microarc oxidation layer on Ti6Al4V alloy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1