主动配电网络中考虑观测冗余分布和拓扑变化的 μPMU 布局

IF 1.6 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Journal of Electrical Engineering & Technology Pub Date : 2024-07-02 DOI:10.1007/s42835-024-01936-2
Dai Wan, Miao Zhao, Guidong He, Liang Che, Chunming Tu, Wenhui Mo
{"title":"主动配电网络中考虑观测冗余分布和拓扑变化的 μPMU 布局","authors":"Dai Wan, Miao Zhao, Guidong He, Liang Che, Chunming Tu, Wenhui Mo","doi":"10.1007/s42835-024-01936-2","DOIUrl":null,"url":null,"abstract":"<p>Placement of μPMUs in active distribution networks (ADNs) can significantly improve the system’s observability. Existing research mostly focused on how to achieve global observability with a minimum number of μPMUs, but ignored the system observability under special cases such as line faults, μPMU failures, and topology changes. To ensure ADN’s observability with a minimum number of μPMUs in both normal and special cases, this paper proposes a μPMU placement method that considers the observability of existing monitoring devices, the distribution of observation redundancy, and the nodal priority of μPMUs placement. Simulation results verify that the proposed method needs fewer μPMUs than existing methods and enhances the stability of observability for achieving the global observability of an AND. Both the economic feasibility and observability performance of the PMU placement are considered.</p>","PeriodicalId":15577,"journal":{"name":"Journal of Electrical Engineering & Technology","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"μPMU Placement Considering the Distribution of Observation Redundancy and Topology Changes in Active Distribution Networks\",\"authors\":\"Dai Wan, Miao Zhao, Guidong He, Liang Che, Chunming Tu, Wenhui Mo\",\"doi\":\"10.1007/s42835-024-01936-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Placement of μPMUs in active distribution networks (ADNs) can significantly improve the system’s observability. Existing research mostly focused on how to achieve global observability with a minimum number of μPMUs, but ignored the system observability under special cases such as line faults, μPMU failures, and topology changes. To ensure ADN’s observability with a minimum number of μPMUs in both normal and special cases, this paper proposes a μPMU placement method that considers the observability of existing monitoring devices, the distribution of observation redundancy, and the nodal priority of μPMUs placement. Simulation results verify that the proposed method needs fewer μPMUs than existing methods and enhances the stability of observability for achieving the global observability of an AND. Both the economic feasibility and observability performance of the PMU placement are considered.</p>\",\"PeriodicalId\":15577,\"journal\":{\"name\":\"Journal of Electrical Engineering & Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrical Engineering & Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s42835-024-01936-2\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Engineering & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s42835-024-01936-2","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

在有源配电网络(ADN)中放置 μPMU 可以显著提高系统的可观测性。现有的研究主要集中在如何用最少的 μPMU 实现全局可观测性,但忽略了线路故障、μPMU 故障和拓扑变化等特殊情况下的系统可观测性。为确保 ADN 在正常和特殊情况下都能以最少的 μPMU 数量实现可观测性,本文提出了一种 μPMU 布置方法,该方法考虑了现有监控设备的可观测性、观测冗余分布以及 μPMU 布置的节点优先级。仿真结果验证了所提出的方法比现有方法需要更少的μPMU,并增强了实现 AND 全局可观测性的可观测性稳定性。我们同时考虑了 PMU 布置的经济可行性和可观测性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
μPMU Placement Considering the Distribution of Observation Redundancy and Topology Changes in Active Distribution Networks

Placement of μPMUs in active distribution networks (ADNs) can significantly improve the system’s observability. Existing research mostly focused on how to achieve global observability with a minimum number of μPMUs, but ignored the system observability under special cases such as line faults, μPMU failures, and topology changes. To ensure ADN’s observability with a minimum number of μPMUs in both normal and special cases, this paper proposes a μPMU placement method that considers the observability of existing monitoring devices, the distribution of observation redundancy, and the nodal priority of μPMUs placement. Simulation results verify that the proposed method needs fewer μPMUs than existing methods and enhances the stability of observability for achieving the global observability of an AND. Both the economic feasibility and observability performance of the PMU placement are considered.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Electrical Engineering & Technology
Journal of Electrical Engineering & Technology ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
4.00
自引率
15.80%
发文量
321
审稿时长
3.8 months
期刊介绍: ournal of Electrical Engineering and Technology (JEET), which is the official publication of the Korean Institute of Electrical Engineers (KIEE) being published bimonthly, released the first issue in March 2006.The journal is open to submission from scholars and experts in the wide areas of electrical engineering technologies. The scope of the journal includes all issues in the field of Electrical Engineering and Technology. Included are techniques for electrical power engineering, electrical machinery and energy conversion systems, electrophysics and applications, information and controls.
期刊最新文献
Parameter Solution of Fractional Order PID Controller for Home Ventilator Based on Genetic-Ant Colony Algorithm Fault Detection of Flexible DC Grid Based on Empirical Wavelet Transform and WOA-CNN Aggregation and Bidding Strategy of Virtual Power Plant Power Management of Hybrid System Using Coronavirus Herd Immunity Optimizer Algorithm A Review on Power System Security Issues in the High Renewable Energy Penetration Environment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1