极寒天气下电缆终端的不均匀热应力导致环氧树脂衬套破裂

IF 3.3 3区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Transactions on Dielectrics and Electrical Insulation Pub Date : 2024-06-21 DOI:10.1109/TDEI.2024.3417412
Qi Li;Boxue Du;WenBo Zhu;Xiaoxiao Kong
{"title":"极寒天气下电缆终端的不均匀热应力导致环氧树脂衬套破裂","authors":"Qi Li;Boxue Du;WenBo Zhu;Xiaoxiao Kong","doi":"10.1109/TDEI.2024.3417412","DOIUrl":null,"url":null,"abstract":"In this article, a simulation model of 110 kV cable termination based on COMSOL is established, and electro thermal coupling characteristics at different temperatures are simulated. Obvious uneven thermal stress distribution inside the termination is found at temperatures below <inline-formula> <tex-math>$- 20~^{\\circ }$ </tex-math></inline-formula>C, due to the difference in thermal expansion coefficients between different materials. Stress concentration at the interface between the metal insert and epoxy resin occurs. Tensile stress along the direction of the electric field in the epoxy increases as the temperature decreases, with a maximum value of 66.7 MPa at <inline-formula> <tex-math>$- 40~^{\\circ }$ </tex-math></inline-formula>C. The electrical treeing and partial discharge (PD) characteristics are investigated in epoxy resin under various thermal stress conditions. It is found that the electrical tree growth is accelerated under low temperatures, which is attributed to the increase in thermal stress and decrease in the toughness of the epoxy bushing. In such circumstances, the electrical tree growth rate is greatly increased, frequently accompanied by a sudden enhancement in PDs and expansion of deterioration channels, which is proved by a phase field model considering the induced thermal stress.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"32 1","pages":"616-623"},"PeriodicalIF":3.3000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Epoxy Bushing Breakdown Caused by Uneven Thermal Stress in Cable Termination Under Extremely Cold Weather\",\"authors\":\"Qi Li;Boxue Du;WenBo Zhu;Xiaoxiao Kong\",\"doi\":\"10.1109/TDEI.2024.3417412\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, a simulation model of 110 kV cable termination based on COMSOL is established, and electro thermal coupling characteristics at different temperatures are simulated. Obvious uneven thermal stress distribution inside the termination is found at temperatures below <inline-formula> <tex-math>$- 20~^{\\\\circ }$ </tex-math></inline-formula>C, due to the difference in thermal expansion coefficients between different materials. Stress concentration at the interface between the metal insert and epoxy resin occurs. Tensile stress along the direction of the electric field in the epoxy increases as the temperature decreases, with a maximum value of 66.7 MPa at <inline-formula> <tex-math>$- 40~^{\\\\circ }$ </tex-math></inline-formula>C. The electrical treeing and partial discharge (PD) characteristics are investigated in epoxy resin under various thermal stress conditions. It is found that the electrical tree growth is accelerated under low temperatures, which is attributed to the increase in thermal stress and decrease in the toughness of the epoxy bushing. In such circumstances, the electrical tree growth rate is greatly increased, frequently accompanied by a sudden enhancement in PDs and expansion of deterioration channels, which is proved by a phase field model considering the induced thermal stress.\",\"PeriodicalId\":13247,\"journal\":{\"name\":\"IEEE Transactions on Dielectrics and Electrical Insulation\",\"volume\":\"32 1\",\"pages\":\"616-623\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Dielectrics and Electrical Insulation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10568235/\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10568235/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文基于COMSOL建立了110kv电缆终端的仿真模型,仿真了不同温度下的电热耦合特性。当温度低于$- 20~^{\circ}$ C时,由于不同材料的热膨胀系数不同,端部内部的热应力分布明显不均匀。在金属镶件和环氧树脂之间的界面处发生应力集中。随着温度的降低,环氧树脂中沿电场方向的拉应力增大,在$- 40~^{\circ}$ c时拉应力最大值为66.7 MPa。研究了不同热应力条件下环氧树脂的电树和局部放电特性。结果表明,低温下电树生长加快,这是由于热应力增大,环氧树脂套管韧性降低所致。在这种情况下,电树生长速度大大增加,往往伴随着pd的突然增强和劣化通道的扩大,考虑诱导热应力的相场模型证明了这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Epoxy Bushing Breakdown Caused by Uneven Thermal Stress in Cable Termination Under Extremely Cold Weather
In this article, a simulation model of 110 kV cable termination based on COMSOL is established, and electro thermal coupling characteristics at different temperatures are simulated. Obvious uneven thermal stress distribution inside the termination is found at temperatures below $- 20~^{\circ }$ C, due to the difference in thermal expansion coefficients between different materials. Stress concentration at the interface between the metal insert and epoxy resin occurs. Tensile stress along the direction of the electric field in the epoxy increases as the temperature decreases, with a maximum value of 66.7 MPa at $- 40~^{\circ }$ C. The electrical treeing and partial discharge (PD) characteristics are investigated in epoxy resin under various thermal stress conditions. It is found that the electrical tree growth is accelerated under low temperatures, which is attributed to the increase in thermal stress and decrease in the toughness of the epoxy bushing. In such circumstances, the electrical tree growth rate is greatly increased, frequently accompanied by a sudden enhancement in PDs and expansion of deterioration channels, which is proved by a phase field model considering the induced thermal stress.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
期刊最新文献
Feature Extraction and Classification of Partial Discharge Signals in C4F7N-Based Gas-Insulated Systems: A Time-Domain and Machine Learning Approach Partial Discharge Evolution of Hairpin Winding Insulation During Multistress Aging Under Various Square Wave Voltages and Environmental Conditions Impact of Accelerated Shock on Partial Discharge Characteristics at the Oil-Paper Insulation Interface of Transformers Numerical Simulation and Analysis of Stress Distribution in Basin-Type Insulator Under Multiphysics Coupling Partial Discharge Pattern Recognition Method Based on SIFT-BOVF and Siamese-VGG With Limited Training Samples for Generator Stator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1