基于拉丁超立方采样法的优化设计和内流特性分析

IF 2.6 4区 综合性期刊 Q2 MULTIDISCIPLINARY SCIENCES Arabian Journal for Science and Engineering Pub Date : 2024-06-25 DOI:10.1007/s13369-024-09229-6
Guangjie Peng, Lie Ma, Shiming Hong, Guangchao Ji, Hao Chang
{"title":"基于拉丁超立方采样法的优化设计和内流特性分析","authors":"Guangjie Peng,&nbsp;Lie Ma,&nbsp;Shiming Hong,&nbsp;Guangchao Ji,&nbsp;Hao Chang","doi":"10.1007/s13369-024-09229-6","DOIUrl":null,"url":null,"abstract":"<div><p>Double-suction centrifugal pumps are ubiquitous in industrial settings and daily life. As energy equipment technology advances, demands for their efficiency and stability continue to rise. This study presents an optimization design approach for such pumps. Employing the Latin cube experimental design method, we optimized five key geometric design parameters of a double-suction centrifugal pump impeller, aiming to maximize efficiency (<i>η</i>). The regression equation yielded predicted impeller efficiency and head of 84.5% and 23.95 m, respectively. Efficiency and head deviations were minimal (0.04% and 2.75%), both within 5%, validating the applicability of the optimization design method combining Latin cube sampling and response surface modeling. The optimized design parameters for the double-suction centrifugal pump are: <i>β</i><sub>1h</sub> = 31.4, <i>β</i><sub>1s</sub> = 15.2, <i>β</i><sub>2h</sub> = 20.2, <i>β</i><sub>2s</sub> = 20.2, <i>φ</i> = 105.1. Numerical simulation results aligned closely with model test data (error &lt; 4%), confirming the accuracy and reliability of the numerical simulation method. The optimized impeller model enhanced pump efficiency by 1.3%, particularly under low flow conditions (improvement &gt; 3%), expanding the pump's efficient operation range. Additionally, the novel Ω (Omega) vortex method effectively captured internal vortex phenomena. Comparative analysis revealed strong static and dynamic interference at the inter-tongue region, dominating pressure pulsation. The optimized model eliminated low-frequency radial force pulsation and reduced force fluctuations under all working conditions. The improved matching between the impeller and chambers led to more uniform and stable flow. This study offers valuable insights for further optimizing double-suction centrifugal pump designs.</p></div>","PeriodicalId":54354,"journal":{"name":"Arabian Journal for Science and Engineering","volume":"50 4","pages":"2715 - 2754"},"PeriodicalIF":2.6000,"publicationDate":"2024-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization Design and Internal Flow Characteristics Analysis Based on Latin Hypercube Sampling Method\",\"authors\":\"Guangjie Peng,&nbsp;Lie Ma,&nbsp;Shiming Hong,&nbsp;Guangchao Ji,&nbsp;Hao Chang\",\"doi\":\"10.1007/s13369-024-09229-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Double-suction centrifugal pumps are ubiquitous in industrial settings and daily life. As energy equipment technology advances, demands for their efficiency and stability continue to rise. This study presents an optimization design approach for such pumps. Employing the Latin cube experimental design method, we optimized five key geometric design parameters of a double-suction centrifugal pump impeller, aiming to maximize efficiency (<i>η</i>). The regression equation yielded predicted impeller efficiency and head of 84.5% and 23.95 m, respectively. Efficiency and head deviations were minimal (0.04% and 2.75%), both within 5%, validating the applicability of the optimization design method combining Latin cube sampling and response surface modeling. The optimized design parameters for the double-suction centrifugal pump are: <i>β</i><sub>1h</sub> = 31.4, <i>β</i><sub>1s</sub> = 15.2, <i>β</i><sub>2h</sub> = 20.2, <i>β</i><sub>2s</sub> = 20.2, <i>φ</i> = 105.1. Numerical simulation results aligned closely with model test data (error &lt; 4%), confirming the accuracy and reliability of the numerical simulation method. The optimized impeller model enhanced pump efficiency by 1.3%, particularly under low flow conditions (improvement &gt; 3%), expanding the pump's efficient operation range. Additionally, the novel Ω (Omega) vortex method effectively captured internal vortex phenomena. Comparative analysis revealed strong static and dynamic interference at the inter-tongue region, dominating pressure pulsation. The optimized model eliminated low-frequency radial force pulsation and reduced force fluctuations under all working conditions. The improved matching between the impeller and chambers led to more uniform and stable flow. This study offers valuable insights for further optimizing double-suction centrifugal pump designs.</p></div>\",\"PeriodicalId\":54354,\"journal\":{\"name\":\"Arabian Journal for Science and Engineering\",\"volume\":\"50 4\",\"pages\":\"2715 - 2754\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arabian Journal for Science and Engineering\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s13369-024-09229-6\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arabian Journal for Science and Engineering","FirstCategoryId":"103","ListUrlMain":"https://link.springer.com/article/10.1007/s13369-024-09229-6","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

双吸离心泵在工业环境和日常生活中无处不在。随着能源设备技术的发展,对其效率和稳定性的要求也不断提高。本研究提出了一种针对此类泵的优化设计方法。我们采用拉丁立方实验设计方法,优化了双吸离心泵叶轮的五个关键几何设计参数,旨在最大限度地提高效率(η)。回归方程得出的预测叶轮效率和扬程分别为 84.5% 和 23.95 米。效率和扬程偏差极小(0.04% 和 2.75%),均在 5%以内,验证了结合拉丁立方体抽样和响应面建模的优化设计方法的适用性。双吸离心泵的优化设计参数为β1h = 31.4,β1s = 15.2,β2h = 20.2,β2s = 20.2,φ = 105.1。数值模拟结果与模型试验数据密切吻合(误差< 4%),证实了数值模拟方法的准确性和可靠性。优化后的叶轮模型使泵的效率提高了 1.3%,尤其是在低流量条件下(提高了 3%),从而扩大了泵的有效运行范围。此外,新颖的 Ω(欧米茄)旋涡方法有效捕捉了内部旋涡现象。对比分析表明,在舌间区存在强烈的静态和动态干扰,压力脉动占主导地位。优化模型消除了低频径向力脉动,减少了所有工况下的力波动。叶轮和腔室之间的匹配得到改善,使流动更加均匀稳定。这项研究为进一步优化双吸离心泵设计提供了宝贵的见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization Design and Internal Flow Characteristics Analysis Based on Latin Hypercube Sampling Method

Double-suction centrifugal pumps are ubiquitous in industrial settings and daily life. As energy equipment technology advances, demands for their efficiency and stability continue to rise. This study presents an optimization design approach for such pumps. Employing the Latin cube experimental design method, we optimized five key geometric design parameters of a double-suction centrifugal pump impeller, aiming to maximize efficiency (η). The regression equation yielded predicted impeller efficiency and head of 84.5% and 23.95 m, respectively. Efficiency and head deviations were minimal (0.04% and 2.75%), both within 5%, validating the applicability of the optimization design method combining Latin cube sampling and response surface modeling. The optimized design parameters for the double-suction centrifugal pump are: β1h = 31.4, β1s = 15.2, β2h = 20.2, β2s = 20.2, φ = 105.1. Numerical simulation results aligned closely with model test data (error < 4%), confirming the accuracy and reliability of the numerical simulation method. The optimized impeller model enhanced pump efficiency by 1.3%, particularly under low flow conditions (improvement > 3%), expanding the pump's efficient operation range. Additionally, the novel Ω (Omega) vortex method effectively captured internal vortex phenomena. Comparative analysis revealed strong static and dynamic interference at the inter-tongue region, dominating pressure pulsation. The optimized model eliminated low-frequency radial force pulsation and reduced force fluctuations under all working conditions. The improved matching between the impeller and chambers led to more uniform and stable flow. This study offers valuable insights for further optimizing double-suction centrifugal pump designs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arabian Journal for Science and Engineering
Arabian Journal for Science and Engineering MULTIDISCIPLINARY SCIENCES-
CiteScore
5.70
自引率
3.40%
发文量
993
期刊介绍: King Fahd University of Petroleum & Minerals (KFUPM) partnered with Springer to publish the Arabian Journal for Science and Engineering (AJSE). AJSE, which has been published by KFUPM since 1975, is a recognized national, regional and international journal that provides a great opportunity for the dissemination of research advances from the Kingdom of Saudi Arabia, MENA and the world.
期刊最新文献
Effects of Combined Utilization of Active Cooler/Heater and Blade-Shaped Nanoparticles in Base Fluid for Performance Improvement of Thermoelectric Generator Mounted in Between Vented Cavities A Review of the Shear Design Provisions of ACI Code and Eurocode for Self-Compacting Concrete, Recycled Aggregate Concrete, and Geopolymer Concrete Beams Advancements in Vertical Axis Wind Turbine Technologies: A Comprehensive Review Improved Electrochemical Performance of Co3O4 Incorporated MnO2 Nanowires for Energy Storage Applications Biological CO2 Utilization; Current Status, Challenges, and Future Directions for Photosynthetic and Non-photosynthetic Route
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1