在临床实践中重复使用 N95/PFF2 口罩:形态和结构分析。

IF 1.5 4区 医学 Q3 NURSING Revista Latino-Americana De Enfermagem Pub Date : 2024-07-05 eCollection Date: 2024-01-01 DOI:10.1590/1518-8345.7045.4209
Viviane Lopes Vimieiro, Claysson Bruno Santos Vimieiro, Adriana Cristina de Oliveira
{"title":"在临床实践中重复使用 N95/PFF2 口罩:形态和结构分析。","authors":"Viviane Lopes Vimieiro, Claysson Bruno Santos Vimieiro, Adriana Cristina de Oliveira","doi":"10.1590/1518-8345.7045.4209","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>to analyze the integrity of N95/PFF2 masks in relation to fiber morphology, porosity, cracks and micro holes, as well as identify visible damage to their structure and components, after seven- and fifteen-day reuse protocols.</p><p><strong>Method: </strong>cross-sectional study. Structural and morphological characteristics of a new N95/PFF2 mask were analyzed in comparison with N95/PFF2 masks (n=10) used in seven- and fifteen-day protocols, through visual inspection and scanning electron microscopy.</p><p><strong>Results: </strong>upon visual inspection, following the seven-day protocol, 40% and 60% of the N95/PFF2 masks showed, respectively, personal identification marks and external and internal dirt. Additionally, 20% exhibited loosening and/or tearing of the straps, while 100% showed some type of damage to the nose clips. In the fifteen-day protocol, all N95/PFF2 masks had dirt, loose straps and damaged nose clips, and 80% had folds. Electronic microscopy revealed an increase in pores and loosening in the weaves from seven days onwards, extending up to fifteen days, with the presence of micro holes and residues.</p><p><strong>Conclusion: </strong>the reuse of N95/PFF2 masks affects their structural and morphological integrity. It is crucial to carry out tests to measure the impact of this practice on the safety of health professionals.</p>","PeriodicalId":48692,"journal":{"name":"Revista Latino-Americana De Enfermagem","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11251686/pdf/","citationCount":"0","resultStr":"{\"title\":\"Reuse of N95/PFF2 masks in clinical practice: morphological and structural analysis.\",\"authors\":\"Viviane Lopes Vimieiro, Claysson Bruno Santos Vimieiro, Adriana Cristina de Oliveira\",\"doi\":\"10.1590/1518-8345.7045.4209\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>to analyze the integrity of N95/PFF2 masks in relation to fiber morphology, porosity, cracks and micro holes, as well as identify visible damage to their structure and components, after seven- and fifteen-day reuse protocols.</p><p><strong>Method: </strong>cross-sectional study. Structural and morphological characteristics of a new N95/PFF2 mask were analyzed in comparison with N95/PFF2 masks (n=10) used in seven- and fifteen-day protocols, through visual inspection and scanning electron microscopy.</p><p><strong>Results: </strong>upon visual inspection, following the seven-day protocol, 40% and 60% of the N95/PFF2 masks showed, respectively, personal identification marks and external and internal dirt. Additionally, 20% exhibited loosening and/or tearing of the straps, while 100% showed some type of damage to the nose clips. In the fifteen-day protocol, all N95/PFF2 masks had dirt, loose straps and damaged nose clips, and 80% had folds. Electronic microscopy revealed an increase in pores and loosening in the weaves from seven days onwards, extending up to fifteen days, with the presence of micro holes and residues.</p><p><strong>Conclusion: </strong>the reuse of N95/PFF2 masks affects their structural and morphological integrity. It is crucial to carry out tests to measure the impact of this practice on the safety of health professionals.</p>\",\"PeriodicalId\":48692,\"journal\":{\"name\":\"Revista Latino-Americana De Enfermagem\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11251686/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Latino-Americana De Enfermagem\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/1518-8345.7045.4209\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"NURSING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Latino-Americana De Enfermagem","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1518-8345.7045.4209","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0

摘要

目的:分析 N95/PFF2 面罩的纤维形态、孔隙率、裂缝和微孔的完整性,并确定其结构和组件在七天和十五天重复使用方案后的可见损坏情况。通过目测和扫描电子显微镜,将新的 N95/PFF2 口罩与在七天和十五天方案中使用过的 N95/PFF2 口罩(n=10)进行比较,分析其结构和形态特征。结果:在七天方案后,经目测,分别有 40% 和 60% 的 N95/PFF2 口罩显示出个人识别标记以及外部和内部污垢。此外,20%的口罩带出现松动和/或撕裂,100%的口罩鼻夹出现某种损坏。在为期 15 天的方案中,所有 N95/PFF2 口罩都有污垢、带子松动和鼻夹损坏,80% 的口罩有褶皱。电子显微镜显示,从七天开始,编织物中的孔隙和松动增加,并持续到十五天,同时出现微孔和残留物。进行测试以衡量这种做法对卫生专业人员安全的影响至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reuse of N95/PFF2 masks in clinical practice: morphological and structural analysis.

Objective: to analyze the integrity of N95/PFF2 masks in relation to fiber morphology, porosity, cracks and micro holes, as well as identify visible damage to their structure and components, after seven- and fifteen-day reuse protocols.

Method: cross-sectional study. Structural and morphological characteristics of a new N95/PFF2 mask were analyzed in comparison with N95/PFF2 masks (n=10) used in seven- and fifteen-day protocols, through visual inspection and scanning electron microscopy.

Results: upon visual inspection, following the seven-day protocol, 40% and 60% of the N95/PFF2 masks showed, respectively, personal identification marks and external and internal dirt. Additionally, 20% exhibited loosening and/or tearing of the straps, while 100% showed some type of damage to the nose clips. In the fifteen-day protocol, all N95/PFF2 masks had dirt, loose straps and damaged nose clips, and 80% had folds. Electronic microscopy revealed an increase in pores and loosening in the weaves from seven days onwards, extending up to fifteen days, with the presence of micro holes and residues.

Conclusion: the reuse of N95/PFF2 masks affects their structural and morphological integrity. It is crucial to carry out tests to measure the impact of this practice on the safety of health professionals.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
11.10%
发文量
142
期刊介绍: A Revista Latino-Americana de Enfermagem constitui-se no órgão oficial de divulgação científica da Escola de Enfermagem de Ribeirão Preto da Universidade de São Paulo e do Centro Colaborador da OMS para o Desenvolvimento da Pesquisa em Enfermagem. Foi criada em abril de 1992 sendo sua primeira edição publicada em janeiro de 1993. No período de 1993 a 1997 tinha periodicidade semestral, de 1997 a 2000 trimestral e, a partir de janeiro de 2001, tem periodicidade bimestral. Caracteriza-se como periódico de circulação internacional, abrangendo predominantemente os países da América Latina e Caribe, embora seja também divulgado para assinantes dos Estados Unidos, Portugal e Espanha.
期刊最新文献
Promoting mental health in the workplace: web software development and validation. Aerospace nurses' competencies in disaster situations: a scoping review. Complications in the use of peripherally inserted central catheter associated with peripheral intravenous therapy: retrospective cohort. Enhancing early bonding between mothers and preterm infants: findings from a Multicentre Qualitative Study of Nurses. Epidemic curves and the profile of patients hospitalized by COVID-19 in a border region.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1