多孔涂层脱落:非骨水泥部分螺纹髋臼组件的晚期失效模式--恢复分析

IF 3.2 3区 材料科学 Q2 MATERIALS SCIENCE, COATINGS & FILMS Journal of Thermal Spray Technology Pub Date : 2024-07-08 DOI:10.1007/s11666-024-01801-8
Łukasz Łapaj, Joanna Sulej-Chojnacka, Justyna Rozwalka, Abdulrahim Alaouir, Tomasz Markiewicz, Paweł Chodór, Jan Kiryluk, Adrian Mróz, Jan Zabrzyński
{"title":"多孔涂层脱落:非骨水泥部分螺纹髋臼组件的晚期失效模式--恢复分析","authors":"Łukasz Łapaj,&nbsp;Joanna Sulej-Chojnacka,&nbsp;Justyna Rozwalka,&nbsp;Abdulrahim Alaouir,&nbsp;Tomasz Markiewicz,&nbsp;Paweł Chodór,&nbsp;Jan Kiryluk,&nbsp;Adrian Mróz,&nbsp;Jan Zabrzyński","doi":"10.1007/s11666-024-01801-8","DOIUrl":null,"url":null,"abstract":"<div><p>Titanium plasma-sprayed (TPS) porous coatings have been used in total hip arthroplasty for decades. They are considered reliable, and very few failure cases have been described so far. This retrieval study described a series of 20 acetabular components—where total or partial debonding occurred during in vivo use and aimed to explain the underlying failure mechanisms. Implants were examined using optical and electron microscopy (SEM), metallographic sections of retrievals were prepared while pathologic samples of periprosthetic tissues were examined for presence of wear debris. Data from metallographic slides indicated that debonding was initiated at free borders of the coating and tended to progress at the interface between the TPS layer and the shell. In some cases, total debonding occurred leading material wear of both the TPS layer and acetabular shell leading to massive release of metallic debris and accelerated polyethylene wear in third body mechanism. SEM examination demonstrated that splats forming the TPS layer exhibited features suggesting a high temperature gradient between the plasma sprayed layer and the substrate material existed, leading to porosity of splats and suboptimal bonding strength. This study demonstrated that coating application parameters and certain design features (screw holes, fins) may promote long-term failure due to debonding. Surgeons should be aware of this complication as it is most likely underreported, while manufacturers should consider more rigorous pre-clinical testing as suboptimal coating bonding may result in failures during long-term clinical use.</p></div>","PeriodicalId":679,"journal":{"name":"Journal of Thermal Spray Technology","volume":"33 6","pages":"2137 - 2152"},"PeriodicalIF":3.2000,"publicationDate":"2024-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11666-024-01801-8.pdf","citationCount":"0","resultStr":"{\"title\":\"Debonding of Porous Coating: A Late Failure Mode of Uncemented, Partially Threaded Acetabular Components—Retrieval Analysis\",\"authors\":\"Łukasz Łapaj,&nbsp;Joanna Sulej-Chojnacka,&nbsp;Justyna Rozwalka,&nbsp;Abdulrahim Alaouir,&nbsp;Tomasz Markiewicz,&nbsp;Paweł Chodór,&nbsp;Jan Kiryluk,&nbsp;Adrian Mróz,&nbsp;Jan Zabrzyński\",\"doi\":\"10.1007/s11666-024-01801-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Titanium plasma-sprayed (TPS) porous coatings have been used in total hip arthroplasty for decades. They are considered reliable, and very few failure cases have been described so far. This retrieval study described a series of 20 acetabular components—where total or partial debonding occurred during in vivo use and aimed to explain the underlying failure mechanisms. Implants were examined using optical and electron microscopy (SEM), metallographic sections of retrievals were prepared while pathologic samples of periprosthetic tissues were examined for presence of wear debris. Data from metallographic slides indicated that debonding was initiated at free borders of the coating and tended to progress at the interface between the TPS layer and the shell. In some cases, total debonding occurred leading material wear of both the TPS layer and acetabular shell leading to massive release of metallic debris and accelerated polyethylene wear in third body mechanism. SEM examination demonstrated that splats forming the TPS layer exhibited features suggesting a high temperature gradient between the plasma sprayed layer and the substrate material existed, leading to porosity of splats and suboptimal bonding strength. This study demonstrated that coating application parameters and certain design features (screw holes, fins) may promote long-term failure due to debonding. Surgeons should be aware of this complication as it is most likely underreported, while manufacturers should consider more rigorous pre-clinical testing as suboptimal coating bonding may result in failures during long-term clinical use.</p></div>\",\"PeriodicalId\":679,\"journal\":{\"name\":\"Journal of Thermal Spray Technology\",\"volume\":\"33 6\",\"pages\":\"2137 - 2152\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s11666-024-01801-8.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Spray Technology\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s11666-024-01801-8\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, COATINGS & FILMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Spray Technology","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s11666-024-01801-8","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, COATINGS & FILMS","Score":null,"Total":0}
引用次数: 0

摘要

钛等离子喷涂(TPS)多孔涂层用于全髋关节置换术已有几十年的历史。它们被认为是可靠的,迄今为止很少有失败病例的描述。这项回收研究描述了一系列 20 个髋臼组件,这些组件在体内使用过程中发生了完全或部分脱落,研究旨在解释其潜在的失效机制。研究人员使用光学和电子显微镜(SEM)对植入物进行了检查,并制作了取回组件的金相切片,同时对假体周围组织的病理样本进行了检查,以确定是否存在磨损碎屑。金相切片的数据表明,脱粘始于涂层的自由边界,并倾向于在 TPS 层和外壳的界面处发展。在某些情况下,TPS 层和髋臼外壳完全脱落,导致材料磨损,从而释放出大量金属碎屑,并加速了第三体机构中聚乙烯的磨损。扫描电子显微镜(SEM)检查显示,形成 TPS 层的飞溅物显示出等离子喷涂层和基底材料之间存在高温梯度,导致飞溅物多孔和粘接强度不理想。这项研究表明,涂层应用参数和某些设计特征(螺孔、鳍片)可能会因脱胶而导致长期失效。外科医生应该注意这种并发症,因为它很可能被低估,而制造商应该考虑进行更严格的临床前测试,因为涂层粘合不理想可能导致长期临床使用中的失败。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Debonding of Porous Coating: A Late Failure Mode of Uncemented, Partially Threaded Acetabular Components—Retrieval Analysis

Titanium plasma-sprayed (TPS) porous coatings have been used in total hip arthroplasty for decades. They are considered reliable, and very few failure cases have been described so far. This retrieval study described a series of 20 acetabular components—where total or partial debonding occurred during in vivo use and aimed to explain the underlying failure mechanisms. Implants were examined using optical and electron microscopy (SEM), metallographic sections of retrievals were prepared while pathologic samples of periprosthetic tissues were examined for presence of wear debris. Data from metallographic slides indicated that debonding was initiated at free borders of the coating and tended to progress at the interface between the TPS layer and the shell. In some cases, total debonding occurred leading material wear of both the TPS layer and acetabular shell leading to massive release of metallic debris and accelerated polyethylene wear in third body mechanism. SEM examination demonstrated that splats forming the TPS layer exhibited features suggesting a high temperature gradient between the plasma sprayed layer and the substrate material existed, leading to porosity of splats and suboptimal bonding strength. This study demonstrated that coating application parameters and certain design features (screw holes, fins) may promote long-term failure due to debonding. Surgeons should be aware of this complication as it is most likely underreported, while manufacturers should consider more rigorous pre-clinical testing as suboptimal coating bonding may result in failures during long-term clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Thermal Spray Technology
Journal of Thermal Spray Technology 工程技术-材料科学:膜
CiteScore
5.20
自引率
25.80%
发文量
198
审稿时长
2.6 months
期刊介绍: From the scientific to the practical, stay on top of advances in this fast-growing coating technology with ASM International''s Journal of Thermal Spray Technology. Critically reviewed scientific papers and engineering articles combine the best of new research with the latest applications and problem solving. A service of the ASM Thermal Spray Society (TSS), the Journal of Thermal Spray Technology covers all fundamental and practical aspects of thermal spray science, including processes, feedstock manufacture, and testing and characterization. The journal contains worldwide coverage of the latest research, products, equipment and process developments, and includes technical note case studies from real-time applications and in-depth topical reviews.
期刊最新文献
Professor Pierre Léon Fauchais: “Passion and Courage” (1937–2024) Microstructural Evolution and Tribological Responses of Heat-Treated AlFeCoNiCr–Cr3C2 Coating In Situ Measurement of Track Shape in Cold Spray Deposits Design and Development of Cost-Effective Equipment for Tribological Evaluation of Thermally Sprayed Abradable Coatings Impact of Hydroxyapatite Powder Particle Size on Mechanical and Electrochemical Properties of Flame-Sprayed Coatings for Titanium Implants
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1