基于生命周期的 pH 和氧气双荧光/磷光传感器的设计和制备及其在模型生理溶液和细胞中的应用探索。

IF 4.4 4区 医学 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY Macromolecular bioscience Pub Date : 2024-07-10 DOI:10.1002/mabi.202400225
Vadim Baigildin, Julia Shakirova, Nina Zharskaia, Elena Ivanova, Sergey Silonov, Viktor Sokolov, Sergey Tunik
{"title":"基于生命周期的 pH 和氧气双荧光/磷光传感器的设计和制备及其在模型生理溶液和细胞中的应用探索。","authors":"Vadim Baigildin,&nbsp;Julia Shakirova,&nbsp;Nina Zharskaia,&nbsp;Elena Ivanova,&nbsp;Sergey Silonov,&nbsp;Viktor Sokolov,&nbsp;Sergey Tunik","doi":"10.1002/mabi.202400225","DOIUrl":null,"url":null,"abstract":"<p>In the present report, a novel dual pH-O<sub>2</sub> sensor based on covalent conjugate of rhodamine 6G and cyclometalated iridium complex with poly(vinylpyrrolidone-<i>block</i>-vinyltetrazole) copolymer is reported. In model physiological solutions the sensor chromophores display independent phosphorescent and fluorescent lifetime responses onto variations in oxygen concentration and pH, respectively. Colocalization studies on Chinese hamster ovary cells demonstrate the preferential localization in endosomes and lysosomes. The fluorescent lifetime imaging microscopy-phosphorescent lifetime imaging microscopy (FLIM-PLIM) experiments show that the phosphorescent O<sub>2</sub> sensor provides unambiguous information onto hypoxia versus normoxia cell status as well as semi-quantitative data on the oxygen concentration in cells in between these two states. However, the results of FLIM measurements indicate that dynamic lifetime interval of the sensor (≈0.5 ns between pH values 5.0 and 8.0) is insufficient even for qualitative estimation of pH in living cells because half-width of lifetime distribution in the studied samples is higher than the sensor dynamic interval. Nevertheless, the variations in rhodamine emission intensity are much higher and allow rough discrimination of acidic and neutral cell conditions. Thus, the results of this study indicate that the suggested approach to the design of dual pH-O<sub>2</sub> sensors makes possible to prepare the biocompatible and water-soluble conjugate with fast cellular uptake.</p>","PeriodicalId":18103,"journal":{"name":"Macromolecular bioscience","volume":null,"pages":null},"PeriodicalIF":4.4000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Preparation of Lifetime-Based Dual Fluorescent/Phosphorescent Sensor of pH and Oxygen and its Exploration in Model Physiological Solutions and Cells\",\"authors\":\"Vadim Baigildin,&nbsp;Julia Shakirova,&nbsp;Nina Zharskaia,&nbsp;Elena Ivanova,&nbsp;Sergey Silonov,&nbsp;Viktor Sokolov,&nbsp;Sergey Tunik\",\"doi\":\"10.1002/mabi.202400225\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In the present report, a novel dual pH-O<sub>2</sub> sensor based on covalent conjugate of rhodamine 6G and cyclometalated iridium complex with poly(vinylpyrrolidone-<i>block</i>-vinyltetrazole) copolymer is reported. In model physiological solutions the sensor chromophores display independent phosphorescent and fluorescent lifetime responses onto variations in oxygen concentration and pH, respectively. Colocalization studies on Chinese hamster ovary cells demonstrate the preferential localization in endosomes and lysosomes. The fluorescent lifetime imaging microscopy-phosphorescent lifetime imaging microscopy (FLIM-PLIM) experiments show that the phosphorescent O<sub>2</sub> sensor provides unambiguous information onto hypoxia versus normoxia cell status as well as semi-quantitative data on the oxygen concentration in cells in between these two states. However, the results of FLIM measurements indicate that dynamic lifetime interval of the sensor (≈0.5 ns between pH values 5.0 and 8.0) is insufficient even for qualitative estimation of pH in living cells because half-width of lifetime distribution in the studied samples is higher than the sensor dynamic interval. Nevertheless, the variations in rhodamine emission intensity are much higher and allow rough discrimination of acidic and neutral cell conditions. Thus, the results of this study indicate that the suggested approach to the design of dual pH-O<sub>2</sub> sensors makes possible to prepare the biocompatible and water-soluble conjugate with fast cellular uptake.</p>\",\"PeriodicalId\":18103,\"journal\":{\"name\":\"Macromolecular bioscience\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Macromolecular bioscience\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/mabi.202400225\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Macromolecular bioscience","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mabi.202400225","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本报告介绍了一种新型 pH-O2 双传感器,它基于罗丹明 6G 和环甲基铱络合物与聚乙烯吡咯烷酮-块状-乙烯基四唑共聚物的共价共轭物。在模型生理溶液中,传感器发色团分别对氧浓度和 pH 值的变化显示出独立的磷光和荧光寿命响应。对中国仓鼠卵巢细胞进行的共定位研究表明,传感器优先定位在内膜和溶酶体中。荧光寿命成像显微镜-磷光寿命成像显微镜(FLIM-PLIM)实验表明,磷光 O2 传感器可提供缺氧与正常缺氧细胞状态的明确信息,以及介于这两种状态之间的细胞中氧浓度的半定量数据。然而,FLIM 测量结果表明,传感器的动态寿命间隔(pH 值 5.0 和 8.0 之间≈0.5 毫微秒)甚至不足以对活细胞中的 pH 值进行定性估计,因为所研究样品中的寿命分布半宽度高于传感器的动态间隔。不过,罗丹明发射强度的变化要大得多,可以粗略区分酸性和中性细胞条件。因此,这项研究的结果表明,所建议的 pH-O2 双传感器设计方法可以制备出生物相容性好、可溶于水且能被细胞快速吸收的共轭物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and Preparation of Lifetime-Based Dual Fluorescent/Phosphorescent Sensor of pH and Oxygen and its Exploration in Model Physiological Solutions and Cells

In the present report, a novel dual pH-O2 sensor based on covalent conjugate of rhodamine 6G and cyclometalated iridium complex with poly(vinylpyrrolidone-block-vinyltetrazole) copolymer is reported. In model physiological solutions the sensor chromophores display independent phosphorescent and fluorescent lifetime responses onto variations in oxygen concentration and pH, respectively. Colocalization studies on Chinese hamster ovary cells demonstrate the preferential localization in endosomes and lysosomes. The fluorescent lifetime imaging microscopy-phosphorescent lifetime imaging microscopy (FLIM-PLIM) experiments show that the phosphorescent O2 sensor provides unambiguous information onto hypoxia versus normoxia cell status as well as semi-quantitative data on the oxygen concentration in cells in between these two states. However, the results of FLIM measurements indicate that dynamic lifetime interval of the sensor (≈0.5 ns between pH values 5.0 and 8.0) is insufficient even for qualitative estimation of pH in living cells because half-width of lifetime distribution in the studied samples is higher than the sensor dynamic interval. Nevertheless, the variations in rhodamine emission intensity are much higher and allow rough discrimination of acidic and neutral cell conditions. Thus, the results of this study indicate that the suggested approach to the design of dual pH-O2 sensors makes possible to prepare the biocompatible and water-soluble conjugate with fast cellular uptake.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Macromolecular bioscience
Macromolecular bioscience 生物-材料科学:生物材料
CiteScore
7.90
自引率
2.20%
发文量
211
审稿时长
1.5 months
期刊介绍: Macromolecular Bioscience is a leading journal at the intersection of polymer and materials sciences with life science and medicine. With an Impact Factor of 2.895 (2018 Journal Impact Factor, Journal Citation Reports (Clarivate Analytics, 2019)), it is currently ranked among the top biomaterials and polymer journals. Macromolecular Bioscience offers an attractive mixture of high-quality Reviews, Feature Articles, Communications, and Full Papers. With average reviewing times below 30 days, publication times of 2.5 months and listing in all major indices, including Medline, Macromolecular Bioscience is the journal of choice for your best contributions at the intersection of polymer and life sciences.
期刊最新文献
In Situ Forming Injectable Gelatin-Based Antibacterial Bioadhesives for Preventing Postoperative Leakage and Abdominal Adhesions. Polyamino Acid Based Zwitterionic Coating can Inhibit Coagulation and Inflammation Through Anti-Fouling and Restoring Microenvironment. Surface Coating of ZIF-8 Nanoparticles with Polyacrylic Acid: A Facile Approach to Enhance Chemical Stability for Biomedical Applications. Biocompatible Zn-Phthalocyanine/Gelatin Nanofiber Membrane for Antibacterial Therapy. The Application of Biomaterial-Based Spinal Cord Tissue Engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1