用超快 UPLC-MS/MS 方法估算人肝微粒体中的 X-376:通过硅学软件和体外分析评估代谢稳定性。

IF 1.3 4区 医学 Q4 PHARMACOLOGY & PHARMACY Journal of pharmacological and toxicological methods Pub Date : 2024-07-01 DOI:10.1016/j.vascn.2024.107540
Mohamed W. Attwa, Ali S. Abdelhameed, Adnan A. Kadi
{"title":"用超快 UPLC-MS/MS 方法估算人肝微粒体中的 X-376:通过硅学软件和体外分析评估代谢稳定性。","authors":"Mohamed W. Attwa,&nbsp;Ali S. Abdelhameed,&nbsp;Adnan A. Kadi","doi":"10.1016/j.vascn.2024.107540","DOIUrl":null,"url":null,"abstract":"<div><p>X-376 is a novel anaplastic lymphoma kinase (ALK) inhibitor that is capable of penetrating the blood brain barrier. This makes it suitable for use in patients with ALK-positive non-small cell lung cancer (NSCLC) who have metastases in the central nervous system. This study developed a highly sensitive, fast, eco-friendly, and reliable UPLC-MS/MS approach to quantify X-376 in human liver microsomes (HLMs). This approach was used to evaluate X-376's metabolic stability in HLMs in vitro. The UPLC-MS/MS analytical technique validation followed US-FDA bio-analytical method validation guidelines. StarDrop software, containing P450 metabolic and DEREK modules, was utilized to scan X-376's chemical structure for metabolic lability and hazardous warnings. X-376 and Encorafenib (ENF as internal standard) were resoluted on the Eclipse Plus C18 column utilizing an isocratic mobile phase method. The X-376 calibration curve was linear from 1 to 3000 ng/mL. The precision and accuracy of this study's UPLC-MS/MS approach were tested for intra- and inter-day measurements. Inter-day accuracy was −1.32% to 9.36% while intra-day accuracy was −1.5% to 10.00%. The intrinsic clearance (Cl<sub>int</sub>) and in vitro half-life (t<sub>1/2</sub>) of X-376 were 59.77 mL/min/kg and 13.56 min. The high extraction ratio of X-376 supports the 50 mg twice-daily dose for ALK-positive NSCLC and CNS metastases patients. In silico software suggests that simple structural changes to the piperazine ring or group substitution in drug design may improve metabolic stability and safety compared to X-376.</p></div>","PeriodicalId":16767,"journal":{"name":"Journal of pharmacological and toxicological methods","volume":"128 ","pages":"Article 107540"},"PeriodicalIF":1.3000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultra-fast UPLC–MS/MS approach for estimating X-376 in human liver microsomes: Evaluation of metabolic stability via in silico software and in vitro analysis\",\"authors\":\"Mohamed W. Attwa,&nbsp;Ali S. Abdelhameed,&nbsp;Adnan A. Kadi\",\"doi\":\"10.1016/j.vascn.2024.107540\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>X-376 is a novel anaplastic lymphoma kinase (ALK) inhibitor that is capable of penetrating the blood brain barrier. This makes it suitable for use in patients with ALK-positive non-small cell lung cancer (NSCLC) who have metastases in the central nervous system. This study developed a highly sensitive, fast, eco-friendly, and reliable UPLC-MS/MS approach to quantify X-376 in human liver microsomes (HLMs). This approach was used to evaluate X-376's metabolic stability in HLMs in vitro. The UPLC-MS/MS analytical technique validation followed US-FDA bio-analytical method validation guidelines. StarDrop software, containing P450 metabolic and DEREK modules, was utilized to scan X-376's chemical structure for metabolic lability and hazardous warnings. X-376 and Encorafenib (ENF as internal standard) were resoluted on the Eclipse Plus C18 column utilizing an isocratic mobile phase method. The X-376 calibration curve was linear from 1 to 3000 ng/mL. The precision and accuracy of this study's UPLC-MS/MS approach were tested for intra- and inter-day measurements. Inter-day accuracy was −1.32% to 9.36% while intra-day accuracy was −1.5% to 10.00%. The intrinsic clearance (Cl<sub>int</sub>) and in vitro half-life (t<sub>1/2</sub>) of X-376 were 59.77 mL/min/kg and 13.56 min. The high extraction ratio of X-376 supports the 50 mg twice-daily dose for ALK-positive NSCLC and CNS metastases patients. In silico software suggests that simple structural changes to the piperazine ring or group substitution in drug design may improve metabolic stability and safety compared to X-376.</p></div>\",\"PeriodicalId\":16767,\"journal\":{\"name\":\"Journal of pharmacological and toxicological methods\",\"volume\":\"128 \",\"pages\":\"Article 107540\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pharmacological and toxicological methods\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1056871924000509\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacological and toxicological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1056871924000509","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

X-376是一种新型无性淋巴瘤激酶(ALK)抑制剂,能够穿透血脑屏障。这使它适合用于中枢神经系统转移的ALK阳性非小细胞肺癌(NSCLC)患者。本研究开发了一种高灵敏、快速、环保、可靠的UPLC-MS/MS方法,用于定量检测人肝微粒体(HLMs)中的X-376。该方法被用于评估X-376在体外肝微粒体中的代谢稳定性。UPLC-MS/MS分析技术的验证遵循了美国食品药物管理局(US-FDA)的生物分析方法验证指南。StarDrop 软件包含 P450 代谢模块和 DEREK 模块,用于扫描 X-376 的化学结构,以确定其代谢稳定性和危险警告。采用等度流动相方法,在Eclipse Plus C18色谱柱上对X-376和安可非尼(内标物为ENF)进行解析。X-376校准曲线在1至3000纳克/毫升之间呈线性关系。本研究采用 UPLC-MS/MS 方法测试了日内和日间测量的精密度和准确度。日间准确度为-1.32%至9.36%,而日内准确度为-1.5%至10.00%。X-376的体内清除率(Clint)和体外半衰期(t1/2)分别为59.77毫升/分钟/千克和13.56分钟。X-376的高萃取率支持对ALK阳性NSCLC和中枢神经系统转移患者采用50毫克、每天两次的剂量。硅学软件表明,与X-376相比,在药物设计中对哌嗪环进行简单的结构改变或基团置换可提高代谢稳定性和安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultra-fast UPLC–MS/MS approach for estimating X-376 in human liver microsomes: Evaluation of metabolic stability via in silico software and in vitro analysis

X-376 is a novel anaplastic lymphoma kinase (ALK) inhibitor that is capable of penetrating the blood brain barrier. This makes it suitable for use in patients with ALK-positive non-small cell lung cancer (NSCLC) who have metastases in the central nervous system. This study developed a highly sensitive, fast, eco-friendly, and reliable UPLC-MS/MS approach to quantify X-376 in human liver microsomes (HLMs). This approach was used to evaluate X-376's metabolic stability in HLMs in vitro. The UPLC-MS/MS analytical technique validation followed US-FDA bio-analytical method validation guidelines. StarDrop software, containing P450 metabolic and DEREK modules, was utilized to scan X-376's chemical structure for metabolic lability and hazardous warnings. X-376 and Encorafenib (ENF as internal standard) were resoluted on the Eclipse Plus C18 column utilizing an isocratic mobile phase method. The X-376 calibration curve was linear from 1 to 3000 ng/mL. The precision and accuracy of this study's UPLC-MS/MS approach were tested for intra- and inter-day measurements. Inter-day accuracy was −1.32% to 9.36% while intra-day accuracy was −1.5% to 10.00%. The intrinsic clearance (Clint) and in vitro half-life (t1/2) of X-376 were 59.77 mL/min/kg and 13.56 min. The high extraction ratio of X-376 supports the 50 mg twice-daily dose for ALK-positive NSCLC and CNS metastases patients. In silico software suggests that simple structural changes to the piperazine ring or group substitution in drug design may improve metabolic stability and safety compared to X-376.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of pharmacological and toxicological methods
Journal of pharmacological and toxicological methods PHARMACOLOGY & PHARMACY-TOXICOLOGY
CiteScore
3.60
自引率
10.50%
发文量
56
审稿时长
26 days
期刊介绍: Journal of Pharmacological and Toxicological Methods publishes original articles on current methods of investigation used in pharmacology and toxicology. Pharmacology and toxicology are defined in the broadest sense, referring to actions of drugs and chemicals on all living systems. With its international editorial board and noted contributors, Journal of Pharmacological and Toxicological Methods is the leading journal devoted exclusively to experimental procedures used by pharmacologists and toxicologists.
期刊最新文献
Molecular imaging of excitability difference between alkaloids/salts (nicotine, nicotinic benzoate, caffeine and arecoline hydrobromide) In-situ polyherbal gel as biomedicine in the management of Alzheimer's disease: Understanding ameliorative potential in Trimethyltin induced neurodegeneration Evaluation of 4 quantification methods for monitoring 16 antidepressant drugs and their metabolites in human plasma by LC-MS/MS Comparative toxicity assessment of selected nanoparticles using different experimental model organisms Evaluating the proarrhythmic risk of delayed-action compounds in serum free cell culture conditions; serum-starvation accelerates/amplifies the effect of probucol on the KCNQ1 + KCNE1 channel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1