{"title":"带 LCL 滤波器的三相并网直流-交流逆变器的故障检测、隔离和估计","authors":"Marouane Laaziz;Florentina Nicolau;Malek Ghanes;Jean-Pierre Barbot;Robert Boisliveau;Nadia Machkour","doi":"10.1109/LCSYS.2024.3416404","DOIUrl":null,"url":null,"abstract":"This letter is dedicated to symmetric and asymmetric fault detection, isolation, and estimation of a three-phase DC-AC (Direct Current-Alternating Current) inverter connected to the grid by three LCL filters. The system modeling and the faults estimation algorithm are performed in the abc frame allowing to take into account phase by phase asymmetrical faults. It is based on a left inversion technique and uses the super-twisting differentiator in order to estimate the state components of the system from the given measurements. Simulations to support the proposed approach are presented.","PeriodicalId":37235,"journal":{"name":"IEEE Control Systems Letters","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fault Detection, Isolation, and Estimation for a Three-Phase Grid Connected DC-AC Inverter With LCL Filters\",\"authors\":\"Marouane Laaziz;Florentina Nicolau;Malek Ghanes;Jean-Pierre Barbot;Robert Boisliveau;Nadia Machkour\",\"doi\":\"10.1109/LCSYS.2024.3416404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This letter is dedicated to symmetric and asymmetric fault detection, isolation, and estimation of a three-phase DC-AC (Direct Current-Alternating Current) inverter connected to the grid by three LCL filters. The system modeling and the faults estimation algorithm are performed in the abc frame allowing to take into account phase by phase asymmetrical faults. It is based on a left inversion technique and uses the super-twisting differentiator in order to estimate the state components of the system from the given measurements. Simulations to support the proposed approach are presented.\",\"PeriodicalId\":37235,\"journal\":{\"name\":\"IEEE Control Systems Letters\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Control Systems Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10561585/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"AUTOMATION & CONTROL SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Control Systems Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10561585/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
Fault Detection, Isolation, and Estimation for a Three-Phase Grid Connected DC-AC Inverter With LCL Filters
This letter is dedicated to symmetric and asymmetric fault detection, isolation, and estimation of a three-phase DC-AC (Direct Current-Alternating Current) inverter connected to the grid by three LCL filters. The system modeling and the faults estimation algorithm are performed in the abc frame allowing to take into account phase by phase asymmetrical faults. It is based on a left inversion technique and uses the super-twisting differentiator in order to estimate the state components of the system from the given measurements. Simulations to support the proposed approach are presented.