原位串行晶体学有助于在低对称性条件下进行 96 孔板结构分析。

IF 2.9 2区 材料科学 Q2 CHEMISTRY, MULTIDISCIPLINARY IUCrJ Pub Date : 2024-09-01 DOI:10.1107/S2052252524005785
Nicolas Foos , Jean-Baptise Florial , Mathias Eymery , Jeremy Sinoir , Franck Felisaz , Marcus Oscarsson , Antonia Beteva , Matthew W. Bowler , Didier Nurizzo , Gergely Papp , Montserrat Soler-Lopez , Max Nanao , Shibom Basu , Andrew A. McCarthy
{"title":"原位串行晶体学有助于在低对称性条件下进行 96 孔板结构分析。","authors":"Nicolas Foos ,&nbsp;Jean-Baptise Florial ,&nbsp;Mathias Eymery ,&nbsp;Jeremy Sinoir ,&nbsp;Franck Felisaz ,&nbsp;Marcus Oscarsson ,&nbsp;Antonia Beteva ,&nbsp;Matthew W. Bowler ,&nbsp;Didier Nurizzo ,&nbsp;Gergely Papp ,&nbsp;Montserrat Soler-Lopez ,&nbsp;Max Nanao ,&nbsp;Shibom Basu ,&nbsp;Andrew A. McCarthy","doi":"10.1107/S2052252524005785","DOIUrl":null,"url":null,"abstract":"<div><p>The determination of a challenging structure in the <em>P</em>1 space group, the lowest symmetry possible, shows how our <em>in situ</em> serial crystallography approach expands the application of crystallization plates as a robust sample delivery method.</p></div><div><p>The advent of serial crystallography has rejuvenated and popularized room-temperature X-ray crystal structure determination. Structures determined at physiological temperature reveal protein flexibility and dynamics. In addition, challenging samples (<em>e.g.</em> large complexes, membrane proteins and viruses) form fragile crystals that are often difficult to harvest for cryo-crystallography. Moreover, a typical serial crystallography experiment requires a large number of microcrystals, mainly achievable through batch crystallization. Many medically relevant samples are expressed in mammalian cell lines, producing a meager quantity of protein that is incompatible with batch crystallization. This can limit the scope of serial crystallography approaches. Direct <em>in situ</em> data collection from a 96-well crystallization plate enables not only the identification of the best diffracting crystallization condition but also the possibility for structure determination under ambient conditions. Here, we describe an <em>in situ</em> serial crystallography (iSX) approach, facilitating direct measurement from crystallization plates mounted on a rapidly exchangeable universal plate holder deployed at a microfocus beamline, ID23-2, at the European Synchrotron Radiation Facility. We applied our iSX approach on a challenging project, autotaxin, a therapeutic target expressed in a stable human cell line, to determine the structure in the lowest-symmetry <em>P</em>1 space group at 3.0 Å resolution. Our <em>in situ</em> data collection strategy provided a complete dataset for structure determination while screening various crystallization conditions. Our data analysis reveals that the iSX approach is highly efficient at a microfocus beamline, improving throughput and demonstrating how crystallization plates can be routinely used as an alternative method of presenting samples for serial crystallography experiments at synchrotrons.</p></div>","PeriodicalId":14775,"journal":{"name":"IUCrJ","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11364034/pdf/","citationCount":"0","resultStr":"{\"title\":\"In situ serial crystallography facilitates 96-well plate structural analysis at low symmetry\",\"authors\":\"Nicolas Foos ,&nbsp;Jean-Baptise Florial ,&nbsp;Mathias Eymery ,&nbsp;Jeremy Sinoir ,&nbsp;Franck Felisaz ,&nbsp;Marcus Oscarsson ,&nbsp;Antonia Beteva ,&nbsp;Matthew W. Bowler ,&nbsp;Didier Nurizzo ,&nbsp;Gergely Papp ,&nbsp;Montserrat Soler-Lopez ,&nbsp;Max Nanao ,&nbsp;Shibom Basu ,&nbsp;Andrew A. McCarthy\",\"doi\":\"10.1107/S2052252524005785\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The determination of a challenging structure in the <em>P</em>1 space group, the lowest symmetry possible, shows how our <em>in situ</em> serial crystallography approach expands the application of crystallization plates as a robust sample delivery method.</p></div><div><p>The advent of serial crystallography has rejuvenated and popularized room-temperature X-ray crystal structure determination. Structures determined at physiological temperature reveal protein flexibility and dynamics. In addition, challenging samples (<em>e.g.</em> large complexes, membrane proteins and viruses) form fragile crystals that are often difficult to harvest for cryo-crystallography. Moreover, a typical serial crystallography experiment requires a large number of microcrystals, mainly achievable through batch crystallization. Many medically relevant samples are expressed in mammalian cell lines, producing a meager quantity of protein that is incompatible with batch crystallization. This can limit the scope of serial crystallography approaches. Direct <em>in situ</em> data collection from a 96-well crystallization plate enables not only the identification of the best diffracting crystallization condition but also the possibility for structure determination under ambient conditions. Here, we describe an <em>in situ</em> serial crystallography (iSX) approach, facilitating direct measurement from crystallization plates mounted on a rapidly exchangeable universal plate holder deployed at a microfocus beamline, ID23-2, at the European Synchrotron Radiation Facility. We applied our iSX approach on a challenging project, autotaxin, a therapeutic target expressed in a stable human cell line, to determine the structure in the lowest-symmetry <em>P</em>1 space group at 3.0 Å resolution. Our <em>in situ</em> data collection strategy provided a complete dataset for structure determination while screening various crystallization conditions. Our data analysis reveals that the iSX approach is highly efficient at a microfocus beamline, improving throughput and demonstrating how crystallization plates can be routinely used as an alternative method of presenting samples for serial crystallography experiments at synchrotrons.</p></div>\",\"PeriodicalId\":14775,\"journal\":{\"name\":\"IUCrJ\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11364034/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IUCrJ\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://www.sciencedirect.com/org/science/article/pii/S2052252524000800\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IUCrJ","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/org/science/article/pii/S2052252524000800","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

系列晶体学的出现使室温 X 射线晶体结构测定技术重新焕发活力并得到普及。在生理温度下测定的晶体结构揭示了蛋白质的灵活性和动态性。此外,具有挑战性的样品(如大型复合物、膜蛋白和病毒)会形成脆弱的晶体,通常难以采集用于冷冻晶体学研究。此外,典型的系列晶体学实验需要大量微晶,这主要是通过批量结晶来实现的。许多医学相关样本是在哺乳动物细胞系中表达的,产生的蛋白质数量很少,不适合批量结晶。这就限制了系列晶体学方法的应用范围。从 96 孔结晶板直接原位采集数据不仅能确定最佳衍射结晶条件,还能在环境条件下进行结构测定。在此,我们介绍一种原位串行晶体学(iSX)方法,这种方法便于从安装在欧洲同步辐射设施微聚焦光束线 ID23-2 上可快速更换的通用板支架上的结晶板进行直接测量。我们将 iSX 方法应用于一个具有挑战性的项目,即在稳定人类细胞系中表达的治疗靶标 autotaxin,以 3.0 Å 的分辨率确定最低对称 P1 空间群的结构。我们的原位数据收集策略为结构测定提供了完整的数据集,同时筛选了各种结晶条件。我们的数据分析显示,iSX 方法在微聚焦光束线中效率很高,提高了吞吐量,并展示了如何将结晶板常规用作同步加速器串行晶体学实验中呈现样品的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In situ serial crystallography facilitates 96-well plate structural analysis at low symmetry

The determination of a challenging structure in the P1 space group, the lowest symmetry possible, shows how our in situ serial crystallography approach expands the application of crystallization plates as a robust sample delivery method.

The advent of serial crystallography has rejuvenated and popularized room-temperature X-ray crystal structure determination. Structures determined at physiological temperature reveal protein flexibility and dynamics. In addition, challenging samples (e.g. large complexes, membrane proteins and viruses) form fragile crystals that are often difficult to harvest for cryo-crystallography. Moreover, a typical serial crystallography experiment requires a large number of microcrystals, mainly achievable through batch crystallization. Many medically relevant samples are expressed in mammalian cell lines, producing a meager quantity of protein that is incompatible with batch crystallization. This can limit the scope of serial crystallography approaches. Direct in situ data collection from a 96-well crystallization plate enables not only the identification of the best diffracting crystallization condition but also the possibility for structure determination under ambient conditions. Here, we describe an in situ serial crystallography (iSX) approach, facilitating direct measurement from crystallization plates mounted on a rapidly exchangeable universal plate holder deployed at a microfocus beamline, ID23-2, at the European Synchrotron Radiation Facility. We applied our iSX approach on a challenging project, autotaxin, a therapeutic target expressed in a stable human cell line, to determine the structure in the lowest-symmetry P1 space group at 3.0 Å resolution. Our in situ data collection strategy provided a complete dataset for structure determination while screening various crystallization conditions. Our data analysis reveals that the iSX approach is highly efficient at a microfocus beamline, improving throughput and demonstrating how crystallization plates can be routinely used as an alternative method of presenting samples for serial crystallography experiments at synchrotrons.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IUCrJ
IUCrJ CHEMISTRY, MULTIDISCIPLINARYCRYSTALLOGRAPH-CRYSTALLOGRAPHY
CiteScore
7.50
自引率
5.10%
发文量
95
审稿时长
10 weeks
期刊介绍: IUCrJ is a new fully open-access peer-reviewed journal from the International Union of Crystallography (IUCr). The journal will publish high-profile articles on all aspects of the sciences and technologies supported by the IUCr via its commissions, including emerging fields where structural results underpin the science reported in the article. Our aim is to make IUCrJ the natural home for high-quality structural science results. Chemists, biologists, physicists and material scientists will be actively encouraged to report their structural studies in IUCrJ.
期刊最新文献
Structure of MltG from Mycobacterium abscessus reveals structural plasticity between composed domains Tuning structural modulation and magnetic properties in metal–organic coordination polymers [CH3NH3]CoxNi1−x(HCOO)3 Quantum refinement in real and reciprocal space using the Phenix and ORCA software Roodmus: a toolkit for benchmarking heterogeneous electron cryo-microscopy reconstructions Using deep-learning predictions reveals a large number of register errors in PDB depositions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1