高分辨率三维显微计算机断层扫描评估非成人眶骨畸形患者的微观结构模式:宏观和微观骨骼特征之间的相关性。

IF 2 3区 工程技术 Q2 ANATOMY & MORPHOLOGY Microscopy Research and Technique Pub Date : 2024-07-14 DOI:10.1002/jemt.24656
Veda Mikasinovic, Ksenija Djukic, Petar Milenkovic, Jelena Jadzic, Petar Milovanovic, Marija Djuric
{"title":"高分辨率三维显微计算机断层扫描评估非成人眶骨畸形患者的微观结构模式:宏观和微观骨骼特征之间的相关性。","authors":"Veda Mikasinovic, Ksenija Djukic, Petar Milenkovic, Jelena Jadzic, Petar Milovanovic, Marija Djuric","doi":"10.1002/jemt.24656","DOIUrl":null,"url":null,"abstract":"<p><p>Skeletal porous lesions such as cribra orbitalia (CO) have long been of interest to bioanthropologists worldwide, mainly due to their high prevalence in osteological material. Previous studies considered CO as an external morphological manifestation, and therefore, research has mainly focused on visible (macroscopic) CO patterns. However, the understanding of CO-induced micro-scale bone changes is still scarce. Therefore, we performed high-resolution micro-computed tomography imaging to investigate three-dimensional CO-induced micro-architectural patterns in non-adults, with a particular focus on the correlation between macroscopic and micro-architectural orbital features. Cortical and trabecular micro-architectural changes in the orbital roof were analyzed in non-adults younger than 15 years, using orbital roof samples with and without macroscopic traces of CO (n = 28). A widely accepted five-grade macroscopic CO scoring system was applied to analyze CO severity. Areas affected with CO (area 1) and areas without macroscopic CO traces (area 2) were analyzed separately. The conducted high-resolution analysis showed that cortical and trabecular micro-architecture varied with CO presence, lesion severity (CO grade), and the analyzed area. Inter-grade comparisons suggested that most of the analyzed micro-architectural parameters were not significantly different between adjacent CO grades. Based on the micro-architectural evaluation of areas 1 and 2, the porous lesions were much more extensive than revealed by gross examination. In addition, micro-architectural differences were particularly pronounced in younger non-adults. In summary, our pilot study suggests that the macroscopic examination of CO reflects only the tip of the iceberg, as the micro-architectural changes seem to be much larger than macroscopically identified. RESEARCH HIGHLIGHTS: Cribra orbitalia (CO) represents orbital porous lesions. A high-resolution microscopic assessment of CO-induced changes in non-adults was done by micro-computed tomography. The microarchitecture was affected by CO presence, CO grade, area, and age.</p>","PeriodicalId":18684,"journal":{"name":"Microscopy Research and Technique","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-resolution three-dimensional micro-computed tomography assessment of micro-architectural patterns in non-adults with cribra orbitalia: Correlation between macro- and micro-scale bone features.\",\"authors\":\"Veda Mikasinovic, Ksenija Djukic, Petar Milenkovic, Jelena Jadzic, Petar Milovanovic, Marija Djuric\",\"doi\":\"10.1002/jemt.24656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Skeletal porous lesions such as cribra orbitalia (CO) have long been of interest to bioanthropologists worldwide, mainly due to their high prevalence in osteological material. Previous studies considered CO as an external morphological manifestation, and therefore, research has mainly focused on visible (macroscopic) CO patterns. However, the understanding of CO-induced micro-scale bone changes is still scarce. Therefore, we performed high-resolution micro-computed tomography imaging to investigate three-dimensional CO-induced micro-architectural patterns in non-adults, with a particular focus on the correlation between macroscopic and micro-architectural orbital features. Cortical and trabecular micro-architectural changes in the orbital roof were analyzed in non-adults younger than 15 years, using orbital roof samples with and without macroscopic traces of CO (n = 28). A widely accepted five-grade macroscopic CO scoring system was applied to analyze CO severity. Areas affected with CO (area 1) and areas without macroscopic CO traces (area 2) were analyzed separately. The conducted high-resolution analysis showed that cortical and trabecular micro-architecture varied with CO presence, lesion severity (CO grade), and the analyzed area. Inter-grade comparisons suggested that most of the analyzed micro-architectural parameters were not significantly different between adjacent CO grades. Based on the micro-architectural evaluation of areas 1 and 2, the porous lesions were much more extensive than revealed by gross examination. In addition, micro-architectural differences were particularly pronounced in younger non-adults. In summary, our pilot study suggests that the macroscopic examination of CO reflects only the tip of the iceberg, as the micro-architectural changes seem to be much larger than macroscopically identified. RESEARCH HIGHLIGHTS: Cribra orbitalia (CO) represents orbital porous lesions. A high-resolution microscopic assessment of CO-induced changes in non-adults was done by micro-computed tomography. The microarchitecture was affected by CO presence, CO grade, area, and age.</p>\",\"PeriodicalId\":18684,\"journal\":{\"name\":\"Microscopy Research and Technique\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microscopy Research and Technique\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/jemt.24656\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANATOMY & MORPHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy Research and Technique","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/jemt.24656","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

长期以来,骨骼多孔病变(如眼眶裂纹)一直受到全世界生物人类学家的关注,这主要是由于它们在骨学材料中的高流行率。以往的研究认为,CO 是一种外部形态表现,因此,研究主要集中在可见的(宏观的)CO 形态上。然而,对 CO 引起的微尺度骨骼变化的了解仍然很少。因此,我们进行了高分辨率显微计算机断层扫描成像,以研究非成人三维 CO 诱导的微观结构模式,尤其关注宏观和微观结构眼眶特征之间的相关性。我们使用有和没有一氧化碳宏观痕迹的眶顶样本(n = 28),分析了 15 岁以下非成年人眶顶皮质和小梁微观结构的变化。采用广为接受的五级宏观 CO 评分系统来分析 CO 的严重程度。分别分析了受一氧化碳影响的区域(区域 1)和无一氧化碳宏观痕迹的区域(区域 2)。高分辨率分析表明,皮质和小梁的微观结构随 CO 的存在、病变严重程度(CO 等级)和分析区域的不同而变化。等级间比较表明,在相邻的 CO 等级之间,大部分分析的微观结构参数没有显著差异。根据对 1 号和 2 号区域的微观结构评估,多孔病变的范围比大体检查发现的要大得多。此外,微观结构的差异在非成年人中尤为明显。总之,我们的试点研究表明,CO 的宏观检查仅反映了冰山一角,因为微观结构的变化似乎比宏观检查发现的要大得多。研究亮点:眼眶裂孔(Cribra orbitalia,CO)是眼眶多孔性病变的一种。通过微型计算机断层扫描,对非成人的 CO 引起的变化进行了高分辨率的显微评估。微观结构受 CO 存在、CO 等级、面积和年龄的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-resolution three-dimensional micro-computed tomography assessment of micro-architectural patterns in non-adults with cribra orbitalia: Correlation between macro- and micro-scale bone features.

Skeletal porous lesions such as cribra orbitalia (CO) have long been of interest to bioanthropologists worldwide, mainly due to their high prevalence in osteological material. Previous studies considered CO as an external morphological manifestation, and therefore, research has mainly focused on visible (macroscopic) CO patterns. However, the understanding of CO-induced micro-scale bone changes is still scarce. Therefore, we performed high-resolution micro-computed tomography imaging to investigate three-dimensional CO-induced micro-architectural patterns in non-adults, with a particular focus on the correlation between macroscopic and micro-architectural orbital features. Cortical and trabecular micro-architectural changes in the orbital roof were analyzed in non-adults younger than 15 years, using orbital roof samples with and without macroscopic traces of CO (n = 28). A widely accepted five-grade macroscopic CO scoring system was applied to analyze CO severity. Areas affected with CO (area 1) and areas without macroscopic CO traces (area 2) were analyzed separately. The conducted high-resolution analysis showed that cortical and trabecular micro-architecture varied with CO presence, lesion severity (CO grade), and the analyzed area. Inter-grade comparisons suggested that most of the analyzed micro-architectural parameters were not significantly different between adjacent CO grades. Based on the micro-architectural evaluation of areas 1 and 2, the porous lesions were much more extensive than revealed by gross examination. In addition, micro-architectural differences were particularly pronounced in younger non-adults. In summary, our pilot study suggests that the macroscopic examination of CO reflects only the tip of the iceberg, as the micro-architectural changes seem to be much larger than macroscopically identified. RESEARCH HIGHLIGHTS: Cribra orbitalia (CO) represents orbital porous lesions. A high-resolution microscopic assessment of CO-induced changes in non-adults was done by micro-computed tomography. The microarchitecture was affected by CO presence, CO grade, area, and age.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microscopy Research and Technique
Microscopy Research and Technique 医学-解剖学与形态学
CiteScore
5.30
自引率
20.00%
发文量
233
审稿时长
4.7 months
期刊介绍: Microscopy Research and Technique (MRT) publishes articles on all aspects of advanced microscopy original architecture and methodologies with applications in the biological, clinical, chemical, and materials sciences. Original basic and applied research as well as technical papers dealing with the various subsets of microscopy are encouraged. MRT is the right form for those developing new microscopy methods or using the microscope to answer key questions in basic and applied research.
期刊最新文献
Challenges and solutions in FISH for formalin-fixed paraffin-embedded tissue: A scoping review. Microplastics induced ileum damage: Morphological and immunohistochemical study. Human lung cancer classification and comprehensive analysis using different machine learning techniques. A novel simplified method for assessing crystal length and crystalline content in dental ceramics Photoactivated riboflavin‐doped hydroxy apatite nanospheres infiltered in orthodontic adhesives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1