{"title":"用于两相热能管理系统的液体和气体工作液的灌装机","authors":"Colin Butler ,&nbsp;Emmanuel Caplanne ,&nbsp;Jeff Punch","doi":"10.1016/j.ohx.2024.e00558","DOIUrl":null,"url":null,"abstract":"<div><p>Two-phase cooling devices are used to remove and dissipate heat from high power-density electronic systems to maintain them within their operating temperature limits. The manufacture of these devices, such as heat pipes, thermosyphons or vapour chambers, involves firstly removing any internal air or non-condensable gases before charging with the required volume of working fluid. This paper presents detailed designs and operating instructions for a single bench-top station for use in a laboratory environment for the vacuum evacuation, degassing and charging of these devices. Two configurations allow for the filling of fluids which are either liquids or gases at standard temperature and pressure conditions. For liquids, the dispensed volume can be measured directly on an integrated burette, while the method of vapour transfer is used for gases.</p><p>The hardware was demonstrated by filling multiple thermosyphon devices with a number of common working fluids used in two-phase systems, including water, acetone and ammonia. It was shown to deliver precise and repeatable filling volumes with average differences compared to target volumes of 1.7% and 10.5% for liquids and gases respectively. The design is intended to be highly customisable where its size can be modified to accommodate filling volume requirements for different applications.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S246806722400052X/pdfft?md5=6666968a2cb2b81f7bd861dece997d67&pid=1-s2.0-S246806722400052X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"A filling rig for liquid and gas working fluids for two-phase thermal management systems\",\"authors\":\"Colin Butler ,&nbsp;Emmanuel Caplanne ,&nbsp;Jeff Punch\",\"doi\":\"10.1016/j.ohx.2024.e00558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Two-phase cooling devices are used to remove and dissipate heat from high power-density electronic systems to maintain them within their operating temperature limits. The manufacture of these devices, such as heat pipes, thermosyphons or vapour chambers, involves firstly removing any internal air or non-condensable gases before charging with the required volume of working fluid. This paper presents detailed designs and operating instructions for a single bench-top station for use in a laboratory environment for the vacuum evacuation, degassing and charging of these devices. Two configurations allow for the filling of fluids which are either liquids or gases at standard temperature and pressure conditions. For liquids, the dispensed volume can be measured directly on an integrated burette, while the method of vapour transfer is used for gases.</p><p>The hardware was demonstrated by filling multiple thermosyphon devices with a number of common working fluids used in two-phase systems, including water, acetone and ammonia. It was shown to deliver precise and repeatable filling volumes with average differences compared to target volumes of 1.7% and 10.5% for liquids and gases respectively. The design is intended to be highly customisable where its size can be modified to accommodate filling volume requirements for different applications.</p></div>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S246806722400052X/pdfft?md5=6666968a2cb2b81f7bd861dece997d67&pid=1-s2.0-S246806722400052X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S246806722400052X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S246806722400052X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

两相冷却装置用于从高功率密度电子系统中排除和散热,使其保持在工作温度范围内。在制造这些设备(如热管、热吸器或蒸汽室)时,首先要去除内部空气或不凝性气体,然后再注入所需量的工作流体。本文介绍了用于实验室环境中对这些设备进行真空抽空、脱气和充气的单个台式工作站的详细设计和操作说明。两种配置可在标准温度和压力条件下填充液体或气体。对于液体,可直接在集成滴定管上测量分配的体积,而对于气体则采用蒸汽传输方法。结果表明,该硬件可提供精确且可重复的填充量,与目标填充量相比,液体和气体的平均差异分别为 1.7% 和 10.5%。该设计具有很强的定制性,其尺寸可根据不同应用的填充量要求进行修改。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A filling rig for liquid and gas working fluids for two-phase thermal management systems

Two-phase cooling devices are used to remove and dissipate heat from high power-density electronic systems to maintain them within their operating temperature limits. The manufacture of these devices, such as heat pipes, thermosyphons or vapour chambers, involves firstly removing any internal air or non-condensable gases before charging with the required volume of working fluid. This paper presents detailed designs and operating instructions for a single bench-top station for use in a laboratory environment for the vacuum evacuation, degassing and charging of these devices. Two configurations allow for the filling of fluids which are either liquids or gases at standard temperature and pressure conditions. For liquids, the dispensed volume can be measured directly on an integrated burette, while the method of vapour transfer is used for gases.

The hardware was demonstrated by filling multiple thermosyphon devices with a number of common working fluids used in two-phase systems, including water, acetone and ammonia. It was shown to deliver precise and repeatable filling volumes with average differences compared to target volumes of 1.7% and 10.5% for liquids and gases respectively. The design is intended to be highly customisable where its size can be modified to accommodate filling volume requirements for different applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1