{"title":"用于灵敏可靠的荧光生物传感的光流体光子晶体光纤平台。","authors":"Baptiste Moeglen-Paget, Jayakumar Perumal, Georges Humbert, Malini Olivo, U S Dinish","doi":"10.1364/BOE.527248","DOIUrl":null,"url":null,"abstract":"<p><p>Biosensing plays a pivotal role in various scientific domains, offering significant contributions to medical diagnostics, environmental monitoring, and biotechnology. Fluorescence biosensing relies on the fluorescence emission from labelled biomolecules to enable sensitive and selective identification and quantification of specific biological targets in various samples. Photonic crystal fibers (PCFs) have led to the development of optofluidic fibers enabling efficient light-liquid interaction within small liquid volume. Herein, we present the development of a user-friendly optofluidic-fiber platform with simple hardware requirements for sensitive and reliable fluorescence biosensing with high measurement repeatability. We demonstrate a sensitivity improvement of the fluorescence emission up to 17 times compared to standard cuvette measurement, with a limit of detection of Cy5 fluorophore as low as 100 pM. The improvement in measurement repeatability is exploited for detecting haptoglobin protein, a relevant biomarker to diagnose several diseases, by using commercially available Cy5 labelled antibodies. The study aims to showcase an optofluidic platform leveraging the benefits provided by optofluidic fibers, which encompass easy light injection, robustness, and high sensitivity.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249680/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optofluidic photonic crystal fiber platform for sensitive and reliable fluorescence based biosensing.\",\"authors\":\"Baptiste Moeglen-Paget, Jayakumar Perumal, Georges Humbert, Malini Olivo, U S Dinish\",\"doi\":\"10.1364/BOE.527248\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Biosensing plays a pivotal role in various scientific domains, offering significant contributions to medical diagnostics, environmental monitoring, and biotechnology. Fluorescence biosensing relies on the fluorescence emission from labelled biomolecules to enable sensitive and selective identification and quantification of specific biological targets in various samples. Photonic crystal fibers (PCFs) have led to the development of optofluidic fibers enabling efficient light-liquid interaction within small liquid volume. Herein, we present the development of a user-friendly optofluidic-fiber platform with simple hardware requirements for sensitive and reliable fluorescence biosensing with high measurement repeatability. We demonstrate a sensitivity improvement of the fluorescence emission up to 17 times compared to standard cuvette measurement, with a limit of detection of Cy5 fluorophore as low as 100 pM. The improvement in measurement repeatability is exploited for detecting haptoglobin protein, a relevant biomarker to diagnose several diseases, by using commercially available Cy5 labelled antibodies. The study aims to showcase an optofluidic platform leveraging the benefits provided by optofluidic fibers, which encompass easy light injection, robustness, and high sensitivity.</p>\",\"PeriodicalId\":8969,\"journal\":{\"name\":\"Biomedical optics express\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249680/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical optics express\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1364/BOE.527248\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.527248","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Optofluidic photonic crystal fiber platform for sensitive and reliable fluorescence based biosensing.
Biosensing plays a pivotal role in various scientific domains, offering significant contributions to medical diagnostics, environmental monitoring, and biotechnology. Fluorescence biosensing relies on the fluorescence emission from labelled biomolecules to enable sensitive and selective identification and quantification of specific biological targets in various samples. Photonic crystal fibers (PCFs) have led to the development of optofluidic fibers enabling efficient light-liquid interaction within small liquid volume. Herein, we present the development of a user-friendly optofluidic-fiber platform with simple hardware requirements for sensitive and reliable fluorescence biosensing with high measurement repeatability. We demonstrate a sensitivity improvement of the fluorescence emission up to 17 times compared to standard cuvette measurement, with a limit of detection of Cy5 fluorophore as low as 100 pM. The improvement in measurement repeatability is exploited for detecting haptoglobin protein, a relevant biomarker to diagnose several diseases, by using commercially available Cy5 labelled antibodies. The study aims to showcase an optofluidic platform leveraging the benefits provided by optofluidic fibers, which encompass easy light injection, robustness, and high sensitivity.
期刊介绍:
The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including:
Tissue optics and spectroscopy
Novel microscopies
Optical coherence tomography
Diffuse and fluorescence tomography
Photoacoustic and multimodal imaging
Molecular imaging and therapies
Nanophotonic biosensing
Optical biophysics/photobiology
Microfluidic optical devices
Vision research.