Manuel Ochoa-Pérez , Jorge Juárez-Gómez , Sarahy Meneses-Aparicio , Dafne Sarahia Guzmán-Hernández , Víctor Lara , Alberto Rojas-Hernández , María Teresa Ramírez-Silva
{"title":"基于硫供体基团修饰的聚合 ß-环糊精膜的六(Cr)选择性电极的设计与优化","authors":"Manuel Ochoa-Pérez , Jorge Juárez-Gómez , Sarahy Meneses-Aparicio , Dafne Sarahia Guzmán-Hernández , Víctor Lara , Alberto Rojas-Hernández , María Teresa Ramírez-Silva","doi":"10.1016/j.snr.2024.100226","DOIUrl":null,"url":null,"abstract":"<div><p>This work presents the design and optimization of a new Cr(VI)-selective electrode. The new sensor is based on modifying a glassy carbon electrode with carbon quantum dots, ß-cyclodextrin, and carbon disulfide. The carbon quantum dots aided the electrical properties of the glassy carbon by improving charge transfer; the electropolymerization of ß-cyclodextrin resulted in a polymeric membrane that functions as a recognition element when modified by adding sulfur donor groups to its structure. Modifying the membrane with sulfur atoms gave the sensor excellent selectivity toward Cr(VI) ions. The electrode synthesis was optimized using a 2<sup>3</sup> factorial design; the factors studied were pH, the number of cycles in the electropolymerization, and the presence or absence of carbon nanoparticles. Eight different electrodes were constructed, and their potentiometric response to different concentrations of Cr(VI) was evaluated for all of them. The analysis of variance of the experimental design found no significant effect of any factor on the response. However, it suggests a strong interaction between the three factors studied. The sensor that presented the best analytical parameters was synthesized at pH 5 and 50 consecutive cycles in the presence of carbon quantum dots. This new electrode, with its response times of 40 s at different concentrations of the metal ion, exhibiting a slope of (66.0 ± 2.1) mV decade<sup>−1</sup> and a detection limit of (5.2 ± 0.1)x10<sup>−7</sup> mol L<sup>−1</sup>, can be used at pH between 0 and 3 without the effect of hydronium ions. The proposed electrode has good reproducibility and excellent selectivity against various metal ions and has significant advantages over other analysis methods. Its cost, ease of construction, easy handling, ease of operation, ease of storage and transportation, as well as good performance, short response time, and high selectivity make this electrode a valuable tool for easy, fast, and reliable monitoring of Cr(VI) in water samples, contributing to the safety and health of our environment.</p></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"8 ","pages":"Article 100226"},"PeriodicalIF":6.5000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666053924000420/pdfft?md5=5326a7086758dee18ee01ace674f2eca&pid=1-s2.0-S2666053924000420-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Design and optimization of a Cr(VI)-Selective Electrode based on a polymeric ß-cyclodextrin membrane modified with sulfur donor groups\",\"authors\":\"Manuel Ochoa-Pérez , Jorge Juárez-Gómez , Sarahy Meneses-Aparicio , Dafne Sarahia Guzmán-Hernández , Víctor Lara , Alberto Rojas-Hernández , María Teresa Ramírez-Silva\",\"doi\":\"10.1016/j.snr.2024.100226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This work presents the design and optimization of a new Cr(VI)-selective electrode. The new sensor is based on modifying a glassy carbon electrode with carbon quantum dots, ß-cyclodextrin, and carbon disulfide. The carbon quantum dots aided the electrical properties of the glassy carbon by improving charge transfer; the electropolymerization of ß-cyclodextrin resulted in a polymeric membrane that functions as a recognition element when modified by adding sulfur donor groups to its structure. Modifying the membrane with sulfur atoms gave the sensor excellent selectivity toward Cr(VI) ions. The electrode synthesis was optimized using a 2<sup>3</sup> factorial design; the factors studied were pH, the number of cycles in the electropolymerization, and the presence or absence of carbon nanoparticles. Eight different electrodes were constructed, and their potentiometric response to different concentrations of Cr(VI) was evaluated for all of them. The analysis of variance of the experimental design found no significant effect of any factor on the response. However, it suggests a strong interaction between the three factors studied. The sensor that presented the best analytical parameters was synthesized at pH 5 and 50 consecutive cycles in the presence of carbon quantum dots. This new electrode, with its response times of 40 s at different concentrations of the metal ion, exhibiting a slope of (66.0 ± 2.1) mV decade<sup>−1</sup> and a detection limit of (5.2 ± 0.1)x10<sup>−7</sup> mol L<sup>−1</sup>, can be used at pH between 0 and 3 without the effect of hydronium ions. The proposed electrode has good reproducibility and excellent selectivity against various metal ions and has significant advantages over other analysis methods. Its cost, ease of construction, easy handling, ease of operation, ease of storage and transportation, as well as good performance, short response time, and high selectivity make this electrode a valuable tool for easy, fast, and reliable monitoring of Cr(VI) in water samples, contributing to the safety and health of our environment.</p></div>\",\"PeriodicalId\":426,\"journal\":{\"name\":\"Sensors and Actuators Reports\",\"volume\":\"8 \",\"pages\":\"Article 100226\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666053924000420/pdfft?md5=5326a7086758dee18ee01ace674f2eca&pid=1-s2.0-S2666053924000420-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666053924000420\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053924000420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
Design and optimization of a Cr(VI)-Selective Electrode based on a polymeric ß-cyclodextrin membrane modified with sulfur donor groups
This work presents the design and optimization of a new Cr(VI)-selective electrode. The new sensor is based on modifying a glassy carbon electrode with carbon quantum dots, ß-cyclodextrin, and carbon disulfide. The carbon quantum dots aided the electrical properties of the glassy carbon by improving charge transfer; the electropolymerization of ß-cyclodextrin resulted in a polymeric membrane that functions as a recognition element when modified by adding sulfur donor groups to its structure. Modifying the membrane with sulfur atoms gave the sensor excellent selectivity toward Cr(VI) ions. The electrode synthesis was optimized using a 23 factorial design; the factors studied were pH, the number of cycles in the electropolymerization, and the presence or absence of carbon nanoparticles. Eight different electrodes were constructed, and their potentiometric response to different concentrations of Cr(VI) was evaluated for all of them. The analysis of variance of the experimental design found no significant effect of any factor on the response. However, it suggests a strong interaction between the three factors studied. The sensor that presented the best analytical parameters was synthesized at pH 5 and 50 consecutive cycles in the presence of carbon quantum dots. This new electrode, with its response times of 40 s at different concentrations of the metal ion, exhibiting a slope of (66.0 ± 2.1) mV decade−1 and a detection limit of (5.2 ± 0.1)x10−7 mol L−1, can be used at pH between 0 and 3 without the effect of hydronium ions. The proposed electrode has good reproducibility and excellent selectivity against various metal ions and has significant advantages over other analysis methods. Its cost, ease of construction, easy handling, ease of operation, ease of storage and transportation, as well as good performance, short response time, and high selectivity make this electrode a valuable tool for easy, fast, and reliable monitoring of Cr(VI) in water samples, contributing to the safety and health of our environment.
期刊介绍:
Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications.
For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.