状态监测系统:用于密封集装箱应用的灵活混合电子方法

M. Panahi, A. Hanson, D. Maddipatla, S. Masihi, B. Narakathu, B. Bazuin, Scott Miller, M. Atashbar
{"title":"状态监测系统:用于密封集装箱应用的灵活混合电子方法","authors":"M. Panahi, A. Hanson, D. Maddipatla, S. Masihi, B. Narakathu, B. Bazuin, Scott Miller, M. Atashbar","doi":"10.37665/631d5y77","DOIUrl":null,"url":null,"abstract":"A comparative study is presented between two advanced flexible hybrid electronics (FHE) systems designed for monitoring temperature within storage containers across various industries, including food, pharmaceuticals, agriculture, automotive, and defense. The first system, a copper-flex system (CFS), employs an 88.9 µm polyimide substrate with 35 µm thick copper traces, coated with a 12.5 µm polyimide solder mask. The second system, a printed-flex system (PFS), utilizes a 127 µm polyimide substrate with high-temperature resistance and tensile strength. Conductive silver ink was screen-printed on the PFS substrate, and electronic components including a temperature sensor were attached. Functional and reliability tests were performed to check the accuracy and durability of the temperature sensor. Further, environmental and mechanical characterizations including moisture and insulation resistance, corrosion, elongation, bending, and terminal bond strength tests were performed based on ASTM and IPC-TM650 standards. Moisture and insulation resistance test on the PFS test coupons without a coating layer indicated stable resistance of approximately 18 MΩ, while permanent color change indicated oxidation of copper on uncoated CFS test coupons. After 72 hours of corrosion test, both the CFS and PFS “meander line” test coupons covered with polyimide showed negligible change in weight and resistance, approximately 0.35%. A Young’s modulus of 7.17 GPa and 2.6 GPa was calculated from the elongation test for the CFS and PFS, respectively. Bending tests on PFS revealed negligible average resistance change (0.1%) during 180° bending cycles, while no impact was recorded on the CFS. During the terminal bond strength test, soldered wires detached from the CFS test coupons at an average force of 43 N, while it was 3.8 N on the PFS test coupons. Both systems with polyimide coating layer demonstrate robustness and reliability for diverse applications in various industries.","PeriodicalId":118222,"journal":{"name":"Journal of Surface Mount Technology","volume":"23 8","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Condition Monitoring System: A Flexible Hybrid Electronics Approach for Sealed Container Applications\",\"authors\":\"M. Panahi, A. Hanson, D. Maddipatla, S. Masihi, B. Narakathu, B. Bazuin, Scott Miller, M. Atashbar\",\"doi\":\"10.37665/631d5y77\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A comparative study is presented between two advanced flexible hybrid electronics (FHE) systems designed for monitoring temperature within storage containers across various industries, including food, pharmaceuticals, agriculture, automotive, and defense. The first system, a copper-flex system (CFS), employs an 88.9 µm polyimide substrate with 35 µm thick copper traces, coated with a 12.5 µm polyimide solder mask. The second system, a printed-flex system (PFS), utilizes a 127 µm polyimide substrate with high-temperature resistance and tensile strength. Conductive silver ink was screen-printed on the PFS substrate, and electronic components including a temperature sensor were attached. Functional and reliability tests were performed to check the accuracy and durability of the temperature sensor. Further, environmental and mechanical characterizations including moisture and insulation resistance, corrosion, elongation, bending, and terminal bond strength tests were performed based on ASTM and IPC-TM650 standards. Moisture and insulation resistance test on the PFS test coupons without a coating layer indicated stable resistance of approximately 18 MΩ, while permanent color change indicated oxidation of copper on uncoated CFS test coupons. After 72 hours of corrosion test, both the CFS and PFS “meander line” test coupons covered with polyimide showed negligible change in weight and resistance, approximately 0.35%. A Young’s modulus of 7.17 GPa and 2.6 GPa was calculated from the elongation test for the CFS and PFS, respectively. Bending tests on PFS revealed negligible average resistance change (0.1%) during 180° bending cycles, while no impact was recorded on the CFS. During the terminal bond strength test, soldered wires detached from the CFS test coupons at an average force of 43 N, while it was 3.8 N on the PFS test coupons. Both systems with polyimide coating layer demonstrate robustness and reliability for diverse applications in various industries.\",\"PeriodicalId\":118222,\"journal\":{\"name\":\"Journal of Surface Mount Technology\",\"volume\":\"23 8\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Surface Mount Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37665/631d5y77\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Surface Mount Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37665/631d5y77","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本报告对两种先进的柔性混合电子(FHE)系统进行了比较研究,这两种系统设计用于监测食品、制药、农业、汽车和国防等各行各业存储容器内的温度。第一个系统是铜柔性系统 (CFS),采用 88.9 微米的聚酰亚胺基底,35 微米厚的铜线,表面涂有 12.5 微米的聚酰亚胺焊接掩膜。第二个系统是印刷柔性系统(PFS),采用 127 微米的聚酰亚胺基底,具有耐高温和抗拉强度。导电银墨被丝网印刷在 PFS 衬底上,并安装了包括温度传感器在内的电子元件。进行了功能和可靠性测试,以检查温度传感器的准确性和耐用性。此外,还根据 ASTM 和 IPC-TM650 标准进行了环境和机械特性测试,包括防潮和绝缘阻抗、腐蚀、伸长率、弯曲和终端结合强度测试。在没有涂层的 PFS 试样上进行的防潮和绝缘电阻测试表明,电阻值稳定在 18 MΩ 左右,而在没有涂层的 CFS 试样上进行的永久性颜色变化则表明铜发生了氧化。经过 72 小时的腐蚀测试后,覆盖聚酰亚胺的 CFS 和 PFS "蜿蜒线 "测试脆片的重量和电阻变化都微乎其微,约为 0.35%。根据伸长测试计算得出,CFS 和 PFS 的杨氏模量分别为 7.17 GPa 和 2.6 GPa。对 PFS 进行的弯曲测试表明,在 180° 的弯曲周期中,平均阻力变化(0.1%)可以忽略不计,而对 CFS 则没有任何影响。在终端粘接强度测试中,CFS 测试脆片上的焊线平均脱落力为 43 N,而 PFS 测试脆片上的脱落力为 3.8 N。这两种带有聚酰亚胺涂层的系统都表现出了坚固性和可靠性,可用于各行各业的各种应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Condition Monitoring System: A Flexible Hybrid Electronics Approach for Sealed Container Applications
A comparative study is presented between two advanced flexible hybrid electronics (FHE) systems designed for monitoring temperature within storage containers across various industries, including food, pharmaceuticals, agriculture, automotive, and defense. The first system, a copper-flex system (CFS), employs an 88.9 µm polyimide substrate with 35 µm thick copper traces, coated with a 12.5 µm polyimide solder mask. The second system, a printed-flex system (PFS), utilizes a 127 µm polyimide substrate with high-temperature resistance and tensile strength. Conductive silver ink was screen-printed on the PFS substrate, and electronic components including a temperature sensor were attached. Functional and reliability tests were performed to check the accuracy and durability of the temperature sensor. Further, environmental and mechanical characterizations including moisture and insulation resistance, corrosion, elongation, bending, and terminal bond strength tests were performed based on ASTM and IPC-TM650 standards. Moisture and insulation resistance test on the PFS test coupons without a coating layer indicated stable resistance of approximately 18 MΩ, while permanent color change indicated oxidation of copper on uncoated CFS test coupons. After 72 hours of corrosion test, both the CFS and PFS “meander line” test coupons covered with polyimide showed negligible change in weight and resistance, approximately 0.35%. A Young’s modulus of 7.17 GPa and 2.6 GPa was calculated from the elongation test for the CFS and PFS, respectively. Bending tests on PFS revealed negligible average resistance change (0.1%) during 180° bending cycles, while no impact was recorded on the CFS. During the terminal bond strength test, soldered wires detached from the CFS test coupons at an average force of 43 N, while it was 3.8 N on the PFS test coupons. Both systems with polyimide coating layer demonstrate robustness and reliability for diverse applications in various industries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Intermetallic Compounds in Solder Alloys: Common Misconceptions Condition Monitoring System: A Flexible Hybrid Electronics Approach for Sealed Container Applications A Novel Method of Incorporating CNT into Additive Manufacturing Electronics Dielectric Material Lower Temperature Soldering Using Supercooled Liquid Metal Modeling the Effects of Thermal Pad Voiding on Quad Flatpack No-lead (QFN) Components
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1