二尖瓣环钙化与心血管死亡率

Mohammad Ashraf Uddin Sultan, H. Hoque, Khurshed Ahmed, M. M. Rahman, Atm Iqbal Hasan, Md Abu Salim, Naveen Sheikh, C. M. Ahmed, N. Fatema
{"title":"二尖瓣环钙化与心血管死亡率","authors":"Mohammad Ashraf Uddin Sultan, H. Hoque, Khurshed Ahmed, M. M. Rahman, Atm Iqbal Hasan, Md Abu Salim, Naveen Sheikh, C. M. Ahmed, N. Fatema","doi":"10.3329/uhj.v3i1.73754","DOIUrl":null,"url":null,"abstract":"Mitral annular calcification (MAC) is a degenerative change involving mitral valve annulus which has an increased cardiovascular mortality and morbidity. After first autoptic description, a diagnostic tool brought cardiac computed tomography (CT) scan to become the gold standard in MAC detection and classification. The Mitral annular calcifications has always represented an issue for cardiac surgeons, being it linked with an increased risk of atrioventricular groove rupture, circumflex artery injury, or embolism during Mitral valve surgery. As a consequence, different surgical techniques have been developed over time in order to reduce the incidence of these dreadful complications. Recently, transcatheter mitral valve replacement (TMVR) has emerged as a valid alternative to surgery in high-risk patients on the basis of TAVR. Both hybrid transatrial, transfemoral, or transapical approaches have been described to deliver balloon-expandable or self-expanding aortic transcatheter valves into the calcified annulus, with conflicting early and long-term results. Tendyne (Abbott Structural Heart, Santa Clara, CA, USA) is a promising transapical-delivered option. Early results have shown effectiveness and safety of this device in patients with MAC and severe mitral valve disease, with the lowest rate of embolization, mortality, and left ventricular outflow tract obstruction (LVOTO) reported so far.\nUniversity Heart Journal 2023; 19(2): 61-65","PeriodicalId":23424,"journal":{"name":"University Heart Journal","volume":"33 11","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mitral annular Calcification and Cardiovascular mortality\",\"authors\":\"Mohammad Ashraf Uddin Sultan, H. Hoque, Khurshed Ahmed, M. M. Rahman, Atm Iqbal Hasan, Md Abu Salim, Naveen Sheikh, C. M. Ahmed, N. Fatema\",\"doi\":\"10.3329/uhj.v3i1.73754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mitral annular calcification (MAC) is a degenerative change involving mitral valve annulus which has an increased cardiovascular mortality and morbidity. After first autoptic description, a diagnostic tool brought cardiac computed tomography (CT) scan to become the gold standard in MAC detection and classification. The Mitral annular calcifications has always represented an issue for cardiac surgeons, being it linked with an increased risk of atrioventricular groove rupture, circumflex artery injury, or embolism during Mitral valve surgery. As a consequence, different surgical techniques have been developed over time in order to reduce the incidence of these dreadful complications. Recently, transcatheter mitral valve replacement (TMVR) has emerged as a valid alternative to surgery in high-risk patients on the basis of TAVR. Both hybrid transatrial, transfemoral, or transapical approaches have been described to deliver balloon-expandable or self-expanding aortic transcatheter valves into the calcified annulus, with conflicting early and long-term results. Tendyne (Abbott Structural Heart, Santa Clara, CA, USA) is a promising transapical-delivered option. Early results have shown effectiveness and safety of this device in patients with MAC and severe mitral valve disease, with the lowest rate of embolization, mortality, and left ventricular outflow tract obstruction (LVOTO) reported so far.\\nUniversity Heart Journal 2023; 19(2): 61-65\",\"PeriodicalId\":23424,\"journal\":{\"name\":\"University Heart Journal\",\"volume\":\"33 11\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"University Heart Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3329/uhj.v3i1.73754\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"University Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3329/uhj.v3i1.73754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

二尖瓣环钙化(MAC)是一种涉及二尖瓣环的退行性病变,会增加心血管疾病的死亡率和发病率。二尖瓣瓣环钙化是二尖瓣瓣环的退行性病变,会增加心血管疾病的死亡率和发病率。在首次自动光学描述之后,一种诊断工具使心脏计算机断层扫描(CT)成为二尖瓣瓣环钙化检测和分类的金标准。二尖瓣环钙化一直是心脏外科医生面临的一个问题,因为它与二尖瓣手术中房室沟破裂、环状动脉损伤或栓塞的风险增加有关。因此,为了降低这些可怕并发症的发生率,不同的手术技术应运而生。最近,在 TAVR 的基础上,经导管二尖瓣置换术(TMVR)成为高危患者手术的有效替代方案。经房、经口或经心尖的混合方法都被描述为将球囊扩张或自扩张的主动脉经导管瓣膜置入钙化的瓣环,但早期和长期的结果却不尽相同。Tendyne(雅培结构性心脏公司,美国加利福尼亚州圣克拉拉)是一种很有前景的经心尖置入选择。早期结果显示,该装置对患有 MAC 和严重二尖瓣疾病的患者有效且安全,栓塞率、死亡率和左室流出道梗阻(LVOTO)是迄今为止报道的最低的:61-65
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mitral annular Calcification and Cardiovascular mortality
Mitral annular calcification (MAC) is a degenerative change involving mitral valve annulus which has an increased cardiovascular mortality and morbidity. After first autoptic description, a diagnostic tool brought cardiac computed tomography (CT) scan to become the gold standard in MAC detection and classification. The Mitral annular calcifications has always represented an issue for cardiac surgeons, being it linked with an increased risk of atrioventricular groove rupture, circumflex artery injury, or embolism during Mitral valve surgery. As a consequence, different surgical techniques have been developed over time in order to reduce the incidence of these dreadful complications. Recently, transcatheter mitral valve replacement (TMVR) has emerged as a valid alternative to surgery in high-risk patients on the basis of TAVR. Both hybrid transatrial, transfemoral, or transapical approaches have been described to deliver balloon-expandable or self-expanding aortic transcatheter valves into the calcified annulus, with conflicting early and long-term results. Tendyne (Abbott Structural Heart, Santa Clara, CA, USA) is a promising transapical-delivered option. Early results have shown effectiveness and safety of this device in patients with MAC and severe mitral valve disease, with the lowest rate of embolization, mortality, and left ventricular outflow tract obstruction (LVOTO) reported so far. University Heart Journal 2023; 19(2): 61-65
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Association of Cardiac Troponin I Levels with the Severity of Coronary Artery Disease in Non-ST Elevation Myocardial Infarction Awareness on MINOCA Minimally Invasive Ascending Aortic Replacement with Concomitant Aortic Valve Replacement, A Case Report The outcome of Autogenous Venous Graft Vs Prosthetic Graft in Peripheral Arterial Disease- Study in Bangladesh Correlation between the GRACE Risk Score and the SYNTAX Score in Patients with Non-ST-Segment Elevation Myocardial Infarction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1