对无交流能力的重症患者进行生理疼痛监测

IF 1 Q3 NURSING Enfermeria Intensiva Pub Date : 2025-01-01 Epub Date: 2024-07-09 DOI:10.1016/j.enfi.2024.04.002
Candelas López-López RN, MSc, PhD , Gemma Robleda-Font RN, MSc, PhD , Gemma Via-Clavero RN, MSc, PhD , Aaron Castanera-Duro RN, MSc, PhD
{"title":"对无交流能力的重症患者进行生理疼痛监测","authors":"Candelas López-López RN, MSc, PhD ,&nbsp;Gemma Robleda-Font RN, MSc, PhD ,&nbsp;Gemma Via-Clavero RN, MSc, PhD ,&nbsp;Aaron Castanera-Duro RN, MSc, PhD","doi":"10.1016/j.enfi.2024.04.002","DOIUrl":null,"url":null,"abstract":"<div><div>Electrophysiological monitoring of pain provides objective measures that allow for pain control and adjustment of analgesia in non-communicative patients.</div><div>Among the available electrophysiological devices, automated infrared pupillometry, Analgesia Nociception Index (ANI), and Nociception Level Index (NOL®) stand out. These non-invasive measurement systems analyze the sympathetic or parasympathetic nervous system response to painful stimuli by observing pupillary dilatation and reactivity (pupillometry), heart rate during respiration (ANI), or a combination of multiple parameters from the nociceptive-autonomic medullary circuit (NOL®). These methods have mainly been used in the monitoring of nociception related to procedures in critically ill patients.</div><div>Furthermore, they have allowed for the prediction, adjustment, and customization of analgesia administration prior to painful procedures. To obtain accurate measurements and properly interpret the values provided by these devices, it is important to consider certain limitations in their use, such as the administration of specific medications or the presence of certain pathologies, due to their influence on the autonomic nervous system response. It is also important to note that the reported level of evidence is limited, as randomized clinical trials in the context of intensive care unit regarding these devices are currently lacking.</div></div>","PeriodicalId":43993,"journal":{"name":"Enfermeria Intensiva","volume":"36 1","pages":"Article 100489"},"PeriodicalIF":1.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitorización fisiológica del dolor en pacientes críticos no comunicativos\",\"authors\":\"Candelas López-López RN, MSc, PhD ,&nbsp;Gemma Robleda-Font RN, MSc, PhD ,&nbsp;Gemma Via-Clavero RN, MSc, PhD ,&nbsp;Aaron Castanera-Duro RN, MSc, PhD\",\"doi\":\"10.1016/j.enfi.2024.04.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Electrophysiological monitoring of pain provides objective measures that allow for pain control and adjustment of analgesia in non-communicative patients.</div><div>Among the available electrophysiological devices, automated infrared pupillometry, Analgesia Nociception Index (ANI), and Nociception Level Index (NOL®) stand out. These non-invasive measurement systems analyze the sympathetic or parasympathetic nervous system response to painful stimuli by observing pupillary dilatation and reactivity (pupillometry), heart rate during respiration (ANI), or a combination of multiple parameters from the nociceptive-autonomic medullary circuit (NOL®). These methods have mainly been used in the monitoring of nociception related to procedures in critically ill patients.</div><div>Furthermore, they have allowed for the prediction, adjustment, and customization of analgesia administration prior to painful procedures. To obtain accurate measurements and properly interpret the values provided by these devices, it is important to consider certain limitations in their use, such as the administration of specific medications or the presence of certain pathologies, due to their influence on the autonomic nervous system response. It is also important to note that the reported level of evidence is limited, as randomized clinical trials in the context of intensive care unit regarding these devices are currently lacking.</div></div>\",\"PeriodicalId\":43993,\"journal\":{\"name\":\"Enfermeria Intensiva\",\"volume\":\"36 1\",\"pages\":\"Article 100489\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Enfermeria Intensiva\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1130239924000518\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"NURSING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Enfermeria Intensiva","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1130239924000518","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0

摘要

疼痛的电生理监测提供了客观的措施,允许疼痛控制和调整非交流患者的镇痛。在现有的电生理设备中,自动红外瞳孔测量仪、镇痛痛觉指数(ANI)和痛觉水平指数(NOL®)最为突出。这些非侵入性测量系统通过观察瞳孔扩张和反应性(瞳孔测量)、呼吸时心率(ANI)或来自伤害-自主髓神经回路(NOL®)的多个参数的组合来分析交感或副交感神经系统对疼痛刺激的反应。这些方法主要用于危重病人手术过程中伤害感觉的监测。此外,它们还允许在疼痛手术之前预测、调整和定制镇痛给药。为了获得准确的测量和正确解释这些装置提供的值,重要的是要考虑其使用中的某些限制,例如特定药物的施用或某些病理的存在,由于它们对自主神经系统反应的影响。同样值得注意的是,报告的证据水平有限,因为目前缺乏在重症监护病房中关于这些装置的随机临床试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Monitorización fisiológica del dolor en pacientes críticos no comunicativos
Electrophysiological monitoring of pain provides objective measures that allow for pain control and adjustment of analgesia in non-communicative patients.
Among the available electrophysiological devices, automated infrared pupillometry, Analgesia Nociception Index (ANI), and Nociception Level Index (NOL®) stand out. These non-invasive measurement systems analyze the sympathetic or parasympathetic nervous system response to painful stimuli by observing pupillary dilatation and reactivity (pupillometry), heart rate during respiration (ANI), or a combination of multiple parameters from the nociceptive-autonomic medullary circuit (NOL®). These methods have mainly been used in the monitoring of nociception related to procedures in critically ill patients.
Furthermore, they have allowed for the prediction, adjustment, and customization of analgesia administration prior to painful procedures. To obtain accurate measurements and properly interpret the values provided by these devices, it is important to consider certain limitations in their use, such as the administration of specific medications or the presence of certain pathologies, due to their influence on the autonomic nervous system response. It is also important to note that the reported level of evidence is limited, as randomized clinical trials in the context of intensive care unit regarding these devices are currently lacking.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.50
自引率
23.10%
发文量
48
期刊介绍: Enfermería Intensiva es el medio de comunicación por antonomasia para todos los profesionales de enfermería españoles que desarrollan su actividad profesional en las unidades de cuidados intensivos o en cualquier otro lugar donde se atiende al paciente crítico. Enfermería Intensiva publica cuatro números al año, cuyos temas son específicos para la enfermería de cuidados intensivos. Es la única publicación en español con carácter nacional y está indexada en prestigiosas bases de datos como International Nursing Index, MEDLINE, Índice de Enfermería, Cuiden, Índice Médico Español, Toxline, etc.
期刊最新文献
Nursing care in a patient with ischemic stroke undergoing endovascular thrombectomy: A case report Roles y contribuciones de enfermeros especialistas y de práctica avanzada en las unidades de cuidados intensivos: una revisión de alcance global con enfoque latinoamericano Impacto de un programa de simulación en la adquisición de competencias en ventanas ecográficas para la atención inicial del paciente politraumatizado en enfermería de cuidados avanzados prehospitalarios Evaluation of the effectiveness of training in basic and assisted communication techniques for intensive care nurses Time under pressure: Exploring the dimensions of time management among critical care nurses
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1