利用二维和三维超声心动图评估狗的左心室流出道和主动脉口面积

IF 1.5 2区 农林科学 Q2 VETERINARY SCIENCES Journal of Veterinary Cardiology Pub Date : 2024-06-26 DOI:10.1016/j.jvc.2024.06.001
S. Lakhdhir , M.L. O'Sullivan , E. Côté , J. Allen
{"title":"利用二维和三维超声心动图评估狗的左心室流出道和主动脉口面积","authors":"S. Lakhdhir ,&nbsp;M.L. O'Sullivan ,&nbsp;E. Côté ,&nbsp;J. Allen","doi":"10.1016/j.jvc.2024.06.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction/objectives</h3><p>In clinical practice, dogs are screened for subaortic stenosis (SAS) using two-dimensional (2DE) and Doppler echocardiography. There is no accepted antemortem diagnostic criterion to distinguish between mild SAS and unaffected, therefore additional means of evaluating the left ventricular outflow tract (LVOT) and aorta may be desirable. This study sought to determine and compare LVOT and aortic orifice areas using 2DE and three-dimensional echocardiography (3DE) in apparently healthy dogs of various breeds and somatotypes.</p></div><div><h3>Animals, materials, and methods</h3><p>Sixty-nine healthy, privately-owned dogs. The LVOT and aortic orifice areas were determined using 2DE aortic valve (AV) diameter-derived area; the continuity equation (CE); and 3DE planimetry of the LVOT, AV, sinus of Valsalva, and sinotubular junction. Orifice areas were indexed to body surface area (BSA).</p></div><div><h3>Results</h3><p>Obtaining 3DE images and performing planimetry were feasible in all dogs. The mean indexed area measured using the 2DE AV diameter (2.85 cm<sup>2</sup>/m<sup>2</sup>) was significantly lower than that derived from 3DE AV planimetry (3.85 cm<sup>2</sup>/m<sup>2</sup>; mean difference, 1.00 cm<sup>2</sup>/m<sup>2</sup>; P&lt;0.001). There was poor agreement between the effective area calculated using the CE and the anatomic areas calculated using 2DE AV diameter and 3DE planimetry. The area calculated using the CE was less than all other calculations of area. Interobserver and intraobserver repeatability and reproducibility for 3DE planimetry were excellent.</p></div><div><h3>Conclusions</h3><p>Methods for determining aortic orifice areas in dogs are not interchangeable, and this must be taken into account if these methods are investigated in the evaluation of dogs with SAS in the future.</p></div>","PeriodicalId":48788,"journal":{"name":"Journal of Veterinary Cardiology","volume":"54 ","pages":"Pages 63-77"},"PeriodicalIF":1.5000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1760273424000559/pdfft?md5=440a189cc8662189d1edf4e8d6347d40&pid=1-s2.0-S1760273424000559-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Use of two- and three-dimensional echocardiography for assessment of the left ventricular outflow tract and aortic orifice areas in dogs\",\"authors\":\"S. Lakhdhir ,&nbsp;M.L. O'Sullivan ,&nbsp;E. Côté ,&nbsp;J. Allen\",\"doi\":\"10.1016/j.jvc.2024.06.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction/objectives</h3><p>In clinical practice, dogs are screened for subaortic stenosis (SAS) using two-dimensional (2DE) and Doppler echocardiography. There is no accepted antemortem diagnostic criterion to distinguish between mild SAS and unaffected, therefore additional means of evaluating the left ventricular outflow tract (LVOT) and aorta may be desirable. This study sought to determine and compare LVOT and aortic orifice areas using 2DE and three-dimensional echocardiography (3DE) in apparently healthy dogs of various breeds and somatotypes.</p></div><div><h3>Animals, materials, and methods</h3><p>Sixty-nine healthy, privately-owned dogs. The LVOT and aortic orifice areas were determined using 2DE aortic valve (AV) diameter-derived area; the continuity equation (CE); and 3DE planimetry of the LVOT, AV, sinus of Valsalva, and sinotubular junction. Orifice areas were indexed to body surface area (BSA).</p></div><div><h3>Results</h3><p>Obtaining 3DE images and performing planimetry were feasible in all dogs. The mean indexed area measured using the 2DE AV diameter (2.85 cm<sup>2</sup>/m<sup>2</sup>) was significantly lower than that derived from 3DE AV planimetry (3.85 cm<sup>2</sup>/m<sup>2</sup>; mean difference, 1.00 cm<sup>2</sup>/m<sup>2</sup>; P&lt;0.001). There was poor agreement between the effective area calculated using the CE and the anatomic areas calculated using 2DE AV diameter and 3DE planimetry. The area calculated using the CE was less than all other calculations of area. Interobserver and intraobserver repeatability and reproducibility for 3DE planimetry were excellent.</p></div><div><h3>Conclusions</h3><p>Methods for determining aortic orifice areas in dogs are not interchangeable, and this must be taken into account if these methods are investigated in the evaluation of dogs with SAS in the future.</p></div>\",\"PeriodicalId\":48788,\"journal\":{\"name\":\"Journal of Veterinary Cardiology\",\"volume\":\"54 \",\"pages\":\"Pages 63-77\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1760273424000559/pdfft?md5=440a189cc8662189d1edf4e8d6347d40&pid=1-s2.0-S1760273424000559-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Veterinary Cardiology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1760273424000559\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Cardiology","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1760273424000559","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

在临床实践中,使用二维(2DE)和多普勒超声心动图对狗进行主动脉瓣下狭窄(SAS)筛查。目前还没有公认的死前诊断标准来区分轻度 SAS 和未受影响的 SAS,因此可能需要额外的方法来评估左心室流出道(LVOT)和主动脉。本研究试图使用二维和三维超声心动图(3DE)确定并比较不同品种和体型的表面健康犬的左心室流出道和主动脉口面积。69 只健康的私人饲养的狗。使用 2DE 主动脉瓣(AV)直径衍生面积、连续性方程(CE)以及 LVOT、AV、Valsalva 窦和窦管交界处的 3DE 平面测量法确定 LVOT 和主动脉口面积。孔口面积与体表面积(BSA)成指数关系。所有狗都能获得 3DE 图像并进行平面测量。使用 2DE AV 直径测量的平均指数面积(2.85 cm/m)明显低于 3DE AV 平面测量得出的指数面积(3.85 cm/m;平均差异为 1.00 cm/m;P<0.001)。使用 CE 计算的有效面积与使用 2DE AV 直径和 3DE 平面测量法计算的解剖面积之间的一致性较差。使用 CE 计算的面积小于所有其他计算的面积。3DE 平面测量法的观察者间和观察者内重复性和再现性都非常好。确定犬主动脉口面积的方法不能互换,如果将来在评估 SAS 犬时研究这些方法,必须考虑到这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Use of two- and three-dimensional echocardiography for assessment of the left ventricular outflow tract and aortic orifice areas in dogs

Introduction/objectives

In clinical practice, dogs are screened for subaortic stenosis (SAS) using two-dimensional (2DE) and Doppler echocardiography. There is no accepted antemortem diagnostic criterion to distinguish between mild SAS and unaffected, therefore additional means of evaluating the left ventricular outflow tract (LVOT) and aorta may be desirable. This study sought to determine and compare LVOT and aortic orifice areas using 2DE and three-dimensional echocardiography (3DE) in apparently healthy dogs of various breeds and somatotypes.

Animals, materials, and methods

Sixty-nine healthy, privately-owned dogs. The LVOT and aortic orifice areas were determined using 2DE aortic valve (AV) diameter-derived area; the continuity equation (CE); and 3DE planimetry of the LVOT, AV, sinus of Valsalva, and sinotubular junction. Orifice areas were indexed to body surface area (BSA).

Results

Obtaining 3DE images and performing planimetry were feasible in all dogs. The mean indexed area measured using the 2DE AV diameter (2.85 cm2/m2) was significantly lower than that derived from 3DE AV planimetry (3.85 cm2/m2; mean difference, 1.00 cm2/m2; P<0.001). There was poor agreement between the effective area calculated using the CE and the anatomic areas calculated using 2DE AV diameter and 3DE planimetry. The area calculated using the CE was less than all other calculations of area. Interobserver and intraobserver repeatability and reproducibility for 3DE planimetry were excellent.

Conclusions

Methods for determining aortic orifice areas in dogs are not interchangeable, and this must be taken into account if these methods are investigated in the evaluation of dogs with SAS in the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Veterinary Cardiology
Journal of Veterinary Cardiology VETERINARY SCIENCES-
CiteScore
2.50
自引率
25.00%
发文量
66
审稿时长
154 days
期刊介绍: The mission of the Journal of Veterinary Cardiology is to publish peer-reviewed reports of the highest quality that promote greater understanding of cardiovascular disease, and enhance the health and well being of animals and humans. The Journal of Veterinary Cardiology publishes original contributions involving research and clinical practice that include prospective and retrospective studies, clinical trials, epidemiology, observational studies, and advances in applied and basic research. The Journal invites submission of original manuscripts. Specific content areas of interest include heart failure, arrhythmias, congenital heart disease, cardiovascular medicine, surgery, hypertension, health outcomes research, diagnostic imaging, interventional techniques, genetics, molecular cardiology, and cardiovascular pathology, pharmacology, and toxicology.
期刊最新文献
Echocardiographic estimates of stroke volume in healthy dogs: comparability, reference intervals, and reproducibility Efficacy and safety of different antiarrhythmic protocols used for rate control in dogs with secondary atrial fibrillation Diagnosis and hybrid interventional and surgical removal of ectopic heartworms (Dirofilaria immitis) in a dog Transjugular patent ductus arteriosus occlusion in a cat using the Vet-PDA Occluder™ device Agreement of echocardiographic and catheterization-based methods of transpulmonary pressure gradient measurement in dogs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1