D. D. Chupova, P. B. Rosnitskiy, O. V. Solontsov, L. R. Gavrilov, V. E. Sinitsyn, E. A. Mershina, O. A. Sapozhnikov, V. A. Khokhlova
{"title":"基于 CT 和 MRI 数据的颅骨超声聚焦畸变补偿技术","authors":"D. D. Chupova, P. B. Rosnitskiy, O. V. Solontsov, L. R. Gavrilov, V. E. Sinitsyn, E. A. Mershina, O. A. Sapozhnikov, V. A. Khokhlova","doi":"10.1134/S1063771024601651","DOIUrl":null,"url":null,"abstract":"<div><p>The study compares the capabilities of using 3D acoustic models of the human head, constructed using magnetic resonance imaging (MRI) and computed tomography (CT) data, to simulate ultrasound beam focusing when passing through skull bones and to compensate for aberrations caused by them. A CT and MRI dataset from one patient was considered. The MRI data were used to reconstruct segments of the human head (skin, skull, and brain) that were homogeneous in their internal structure. The most realistic CT model took into account the internal inhomogeneities of the skull bones and soft tissues. Field simulations and compensation for aberrations were performed using the Rayleigh integral and pseudospectral method for solving the wave equation in an inhomogeneous medium, implemented in the k-Wave software package. The transducer was considered to be a fully populated 256-element phased array with a frequency of 1 MHz and radius of curvature and an aperture of 200 mm. It was shown that when aberrations were compensated using an inhomogeneous CT model and a homogeneous MRI model, the pressure amplitude at the focus and focusing efficiency were different by less than 10%. Thus, a homogeneous MRI model can be used for preoperative assessment of the feasibility of transcranial ultrasound therapy. During therapy, it is preferable to take into account the internal structure of the skull bones based on CT data.</p></div>","PeriodicalId":455,"journal":{"name":"Acoustical Physics","volume":"70 2","pages":"288 - 298"},"PeriodicalIF":0.9000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Compensation for Aberrations When Focusing Ultrasound Through the Skull Based on CT and MRI Data\",\"authors\":\"D. D. Chupova, P. B. Rosnitskiy, O. V. Solontsov, L. R. Gavrilov, V. E. Sinitsyn, E. A. Mershina, O. A. Sapozhnikov, V. A. Khokhlova\",\"doi\":\"10.1134/S1063771024601651\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The study compares the capabilities of using 3D acoustic models of the human head, constructed using magnetic resonance imaging (MRI) and computed tomography (CT) data, to simulate ultrasound beam focusing when passing through skull bones and to compensate for aberrations caused by them. A CT and MRI dataset from one patient was considered. The MRI data were used to reconstruct segments of the human head (skin, skull, and brain) that were homogeneous in their internal structure. The most realistic CT model took into account the internal inhomogeneities of the skull bones and soft tissues. Field simulations and compensation for aberrations were performed using the Rayleigh integral and pseudospectral method for solving the wave equation in an inhomogeneous medium, implemented in the k-Wave software package. The transducer was considered to be a fully populated 256-element phased array with a frequency of 1 MHz and radius of curvature and an aperture of 200 mm. It was shown that when aberrations were compensated using an inhomogeneous CT model and a homogeneous MRI model, the pressure amplitude at the focus and focusing efficiency were different by less than 10%. Thus, a homogeneous MRI model can be used for preoperative assessment of the feasibility of transcranial ultrasound therapy. During therapy, it is preferable to take into account the internal structure of the skull bones based on CT data.</p></div>\",\"PeriodicalId\":455,\"journal\":{\"name\":\"Acoustical Physics\",\"volume\":\"70 2\",\"pages\":\"288 - 298\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acoustical Physics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1063771024601651\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acoustical Physics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1134/S1063771024601651","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ACOUSTICS","Score":null,"Total":0}
Compensation for Aberrations When Focusing Ultrasound Through the Skull Based on CT and MRI Data
The study compares the capabilities of using 3D acoustic models of the human head, constructed using magnetic resonance imaging (MRI) and computed tomography (CT) data, to simulate ultrasound beam focusing when passing through skull bones and to compensate for aberrations caused by them. A CT and MRI dataset from one patient was considered. The MRI data were used to reconstruct segments of the human head (skin, skull, and brain) that were homogeneous in their internal structure. The most realistic CT model took into account the internal inhomogeneities of the skull bones and soft tissues. Field simulations and compensation for aberrations were performed using the Rayleigh integral and pseudospectral method for solving the wave equation in an inhomogeneous medium, implemented in the k-Wave software package. The transducer was considered to be a fully populated 256-element phased array with a frequency of 1 MHz and radius of curvature and an aperture of 200 mm. It was shown that when aberrations were compensated using an inhomogeneous CT model and a homogeneous MRI model, the pressure amplitude at the focus and focusing efficiency were different by less than 10%. Thus, a homogeneous MRI model can be used for preoperative assessment of the feasibility of transcranial ultrasound therapy. During therapy, it is preferable to take into account the internal structure of the skull bones based on CT data.
期刊介绍:
Acoustical Physics is an international peer reviewed journal published with the participation of the Russian Academy of Sciences. It covers theoretical and experimental aspects of basic and applied acoustics: classical problems of linear acoustics and wave theory; nonlinear acoustics; physical acoustics; ocean acoustics and hydroacoustics; atmospheric and aeroacoustics; acoustics of structurally inhomogeneous solids; geological acoustics; acoustical ecology, noise and vibration; chamber acoustics, musical acoustics; acoustic signals processing, computer simulations; acoustics of living systems, biomedical acoustics; physical principles of engineering acoustics. The journal publishes critical reviews, original articles, short communications, and letters to the editor. It covers theoretical and experimental aspects of basic and applied acoustics. The journal welcomes manuscripts from all countries in the English or Russian language.