{"title":"根据肿瘤形态估算磁热疗的注射标准","authors":"Amritpal Singh, Neeraj Kumar","doi":"10.1088/2057-1976/ad64d8","DOIUrl":null,"url":null,"abstract":"<p><p>Intratumoral multi-injection strategy enhances the efficacy of magnetic nanoparticle hyperthermia therapy (MNPH). In this study, criteria for the selection of injections and their location depending on the tumor shape/geometry are developed. The developed strategy is based on the thermal dosimetry results of different invasive 3D tumor models during MNPH simulation. MNPH simulations are conducted on physical tumor tissue models encased within healthy tissue. The tumor shapes are geometrically divided into a central tumor region containing maximum tumor volume and a peripheral tumor portion protruding in any random direction. The concepts of core and invasive radius are used to geometrically divide the tumor volume. Primary & secondary injections are used to inject MNP fluid into these respective tumor regions based on the invasiveness of the tumor. The optimization strategy is devised based on the zone of influence of primary & secondary injection. Results indicate that the zone of influence of secondary injection lies between 0.7 and 0.8 times the radial distance between the center of the tumor core and branch node point (extreme far endpoint on the invasive tumor surface). Additionally, the multi-injection strategy is more effective when the protrusion volume exceeds10%of the total volume. The proposed algorithm is used to devise multi-injection strategies for arbitrarily shaped tumors and will assist in pre-planning magnetic nanoparticle hyperthermia therapy.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimation of the injection criteria for magnetic hyperthermia therapy based on tumor morphology.\",\"authors\":\"Amritpal Singh, Neeraj Kumar\",\"doi\":\"10.1088/2057-1976/ad64d8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Intratumoral multi-injection strategy enhances the efficacy of magnetic nanoparticle hyperthermia therapy (MNPH). In this study, criteria for the selection of injections and their location depending on the tumor shape/geometry are developed. The developed strategy is based on the thermal dosimetry results of different invasive 3D tumor models during MNPH simulation. MNPH simulations are conducted on physical tumor tissue models encased within healthy tissue. The tumor shapes are geometrically divided into a central tumor region containing maximum tumor volume and a peripheral tumor portion protruding in any random direction. The concepts of core and invasive radius are used to geometrically divide the tumor volume. Primary & secondary injections are used to inject MNP fluid into these respective tumor regions based on the invasiveness of the tumor. The optimization strategy is devised based on the zone of influence of primary & secondary injection. Results indicate that the zone of influence of secondary injection lies between 0.7 and 0.8 times the radial distance between the center of the tumor core and branch node point (extreme far endpoint on the invasive tumor surface). Additionally, the multi-injection strategy is more effective when the protrusion volume exceeds10%of the total volume. The proposed algorithm is used to devise multi-injection strategies for arbitrarily shaped tumors and will assist in pre-planning magnetic nanoparticle hyperthermia therapy.</p>\",\"PeriodicalId\":8896,\"journal\":{\"name\":\"Biomedical Physics & Engineering Express\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Physics & Engineering Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2057-1976/ad64d8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/ad64d8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Estimation of the injection criteria for magnetic hyperthermia therapy based on tumor morphology.
Intratumoral multi-injection strategy enhances the efficacy of magnetic nanoparticle hyperthermia therapy (MNPH). In this study, criteria for the selection of injections and their location depending on the tumor shape/geometry are developed. The developed strategy is based on the thermal dosimetry results of different invasive 3D tumor models during MNPH simulation. MNPH simulations are conducted on physical tumor tissue models encased within healthy tissue. The tumor shapes are geometrically divided into a central tumor region containing maximum tumor volume and a peripheral tumor portion protruding in any random direction. The concepts of core and invasive radius are used to geometrically divide the tumor volume. Primary & secondary injections are used to inject MNP fluid into these respective tumor regions based on the invasiveness of the tumor. The optimization strategy is devised based on the zone of influence of primary & secondary injection. Results indicate that the zone of influence of secondary injection lies between 0.7 and 0.8 times the radial distance between the center of the tumor core and branch node point (extreme far endpoint on the invasive tumor surface). Additionally, the multi-injection strategy is more effective when the protrusion volume exceeds10%of the total volume. The proposed algorithm is used to devise multi-injection strategies for arbitrarily shaped tumors and will assist in pre-planning magnetic nanoparticle hyperthermia therapy.
期刊介绍:
BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.