Hiro Kobayashi, Franz Sebastian Schwindling, Akinori Tasaka, Peter Rammelsberg, Shuichiro Yamashita, Stefan Rues
{"title":"壁厚对 3D 打印机制造的空心氧化锆人工牙形状精度的影响。","authors":"Hiro Kobayashi, Franz Sebastian Schwindling, Akinori Tasaka, Peter Rammelsberg, Shuichiro Yamashita, Stefan Rues","doi":"10.2186/jpr.JPR_D_23_00300","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to analyze how the wall thickness of 3D-printed hollow zirconia teeth affects shape accuracy.</p><p><strong>Methods: </strong>Datasets with measurement points were created for different artificial teeth resembling the mandibular right first molar (Geomagic Design X, 3D Systems). Reference distances were 9.8 mm for mesio-distal direction (M-D), 10.9 mm for bucco-lingual direction (B-L), 7.0 mm for MB-BB and DB-BB, and 4.5 mm for ML-LB and DL-LB. The outer geometry was identical for all artificial teeth with wall thicknesses of 0.30, 0.50, 0.75, and 1.00 mm. Twenty zirconia teeth were fabricated using a 3D printer (CeraFab 7500 Dental, Lithoz) for each group and sintered before support removal. After performing analog distance measurements using a micrometer screw, the digital distance measurements and angular deviations between measurement points on 3D scans were analyzed. Possible effects were investigated using nonparametric ANOVA, followed by Tukey's honest significant difference (HSD) test for multiple comparisons.</p><p><strong>Results: </strong>The shape accuracy was acceptable for artificial teeth with wall thicknesses of ≥0.5 mm. The largest distance deviation was observed for a wall thickness of 0.3 mm. In particular, DB-BB showed a median deviation of >56.2 µm, which is significantly larger than that for other test groups, ranging from 7.4-9.5 µm (P < 0.05). In most cases, angular deviations were the largest for teeth with 0.3-mm wall thickness (11.6°) and remained below 5.0° for the other test groups.</p><p><strong>Conclusions: </strong>Acceptable accuracy was obtained for artificial teeth with wall thicknesses of at least 0.5 mm.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of wall thickness on shape accuracy of hollow zirconia artificial teeth fabricated by a 3D printer.\",\"authors\":\"Hiro Kobayashi, Franz Sebastian Schwindling, Akinori Tasaka, Peter Rammelsberg, Shuichiro Yamashita, Stefan Rues\",\"doi\":\"10.2186/jpr.JPR_D_23_00300\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to analyze how the wall thickness of 3D-printed hollow zirconia teeth affects shape accuracy.</p><p><strong>Methods: </strong>Datasets with measurement points were created for different artificial teeth resembling the mandibular right first molar (Geomagic Design X, 3D Systems). Reference distances were 9.8 mm for mesio-distal direction (M-D), 10.9 mm for bucco-lingual direction (B-L), 7.0 mm for MB-BB and DB-BB, and 4.5 mm for ML-LB and DL-LB. The outer geometry was identical for all artificial teeth with wall thicknesses of 0.30, 0.50, 0.75, and 1.00 mm. Twenty zirconia teeth were fabricated using a 3D printer (CeraFab 7500 Dental, Lithoz) for each group and sintered before support removal. After performing analog distance measurements using a micrometer screw, the digital distance measurements and angular deviations between measurement points on 3D scans were analyzed. Possible effects were investigated using nonparametric ANOVA, followed by Tukey's honest significant difference (HSD) test for multiple comparisons.</p><p><strong>Results: </strong>The shape accuracy was acceptable for artificial teeth with wall thicknesses of ≥0.5 mm. The largest distance deviation was observed for a wall thickness of 0.3 mm. In particular, DB-BB showed a median deviation of >56.2 µm, which is significantly larger than that for other test groups, ranging from 7.4-9.5 µm (P < 0.05). In most cases, angular deviations were the largest for teeth with 0.3-mm wall thickness (11.6°) and remained below 5.0° for the other test groups.</p><p><strong>Conclusions: </strong>Acceptable accuracy was obtained for artificial teeth with wall thicknesses of at least 0.5 mm.</p>\",\"PeriodicalId\":16887,\"journal\":{\"name\":\"Journal of prosthodontic research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of prosthodontic research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2186/jpr.JPR_D_23_00300\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of prosthodontic research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_23_00300","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Effect of wall thickness on shape accuracy of hollow zirconia artificial teeth fabricated by a 3D printer.
Purpose: This study aimed to analyze how the wall thickness of 3D-printed hollow zirconia teeth affects shape accuracy.
Methods: Datasets with measurement points were created for different artificial teeth resembling the mandibular right first molar (Geomagic Design X, 3D Systems). Reference distances were 9.8 mm for mesio-distal direction (M-D), 10.9 mm for bucco-lingual direction (B-L), 7.0 mm for MB-BB and DB-BB, and 4.5 mm for ML-LB and DL-LB. The outer geometry was identical for all artificial teeth with wall thicknesses of 0.30, 0.50, 0.75, and 1.00 mm. Twenty zirconia teeth were fabricated using a 3D printer (CeraFab 7500 Dental, Lithoz) for each group and sintered before support removal. After performing analog distance measurements using a micrometer screw, the digital distance measurements and angular deviations between measurement points on 3D scans were analyzed. Possible effects were investigated using nonparametric ANOVA, followed by Tukey's honest significant difference (HSD) test for multiple comparisons.
Results: The shape accuracy was acceptable for artificial teeth with wall thicknesses of ≥0.5 mm. The largest distance deviation was observed for a wall thickness of 0.3 mm. In particular, DB-BB showed a median deviation of >56.2 µm, which is significantly larger than that for other test groups, ranging from 7.4-9.5 µm (P < 0.05). In most cases, angular deviations were the largest for teeth with 0.3-mm wall thickness (11.6°) and remained below 5.0° for the other test groups.
Conclusions: Acceptable accuracy was obtained for artificial teeth with wall thicknesses of at least 0.5 mm.
期刊介绍:
Journal of Prosthodontic Research is published 4 times annually, in January, April, July, and October, under supervision by the Editorial Board of Japan Prosthodontic Society, which selects all materials submitted for publication.
Journal of Prosthodontic Research originated as an official journal of Japan Prosthodontic Society. It has recently developed a long-range plan to become the most prestigious Asian journal of dental research regarding all aspects of oral and occlusal rehabilitation, fixed/removable prosthodontics, oral implantology and applied oral biology and physiology. The Journal will cover all diagnostic and clinical management aspects necessary to reestablish subjective and objective harmonious oral aesthetics and function.
The most-targeted topics:
1) Clinical Epidemiology and Prosthodontics
2) Fixed/Removable Prosthodontics
3) Oral Implantology
4) Prosthodontics-Related Biosciences (Regenerative Medicine, Bone Biology, Mechanobiology, Microbiology/Immunology)
5) Oral Physiology and Biomechanics (Masticating and Swallowing Function, Parafunction, e.g., bruxism)
6) Orofacial Pain and Temporomandibular Disorders (TMDs)
7) Adhesive Dentistry / Dental Materials / Aesthetic Dentistry
8) Maxillofacial Prosthodontics and Dysphagia Rehabilitation
9) Digital Dentistry
Prosthodontic treatment may become necessary as a result of developmental or acquired disturbances in the orofacial region, of orofacial trauma, or of a variety of dental and oral diseases and orofacial pain conditions.
Reviews, Original articles, technical procedure and case reports can be submitted. Letters to the Editor commenting on papers or any aspect of Journal of Prosthodontic Research are welcomed.