Christina C. Tam, Wen-Xian Du, Yangyang Wang, Andrew R. Flannery, Xiaohua He
{"title":"利用 CANARY 生物传感器测定法快速灵敏地检测食品基质中产志贺毒素大肠杆菌 (STEC)","authors":"Christina C. Tam, Wen-Xian Du, Yangyang Wang, Andrew R. Flannery, Xiaohua He","doi":"10.3390/toxins16070325","DOIUrl":null,"url":null,"abstract":"Shiga toxin-producing Escherichia coli (STEC) causes a wide spectrum of diseases including hemorrhagic colitis and hemolytic uremic syndrome (HUS). Previously, we developed a rapid, sensitive, and potentially portable assay that identified STEC by detecting Shiga toxin (Stx) using a B-cell based biosensor platform. We applied this assay to detect Stx2 present in food samples that have been implicated in previous STEC foodborne outbreaks (milk, lettuce, and beef). The STEC enrichment medium, modified Tryptone Soy Broth (mTSB), inhibited the biosensor assay, but dilution with the assay buffer relieved this effect. Results with Stx2a toxoid-spiked food samples indicated an estimated limit of detection (LOD) of ≈4 ng/mL. When this assay was applied to food samples inoculated with STEC, it was able to detect 0.4 CFU/g or 0.4 CFU/mL of STEC at 16 h post incubation (hpi) in an enrichment medium containing mitomycin C. Importantly, this assay was even able to detect STEC strains that were high expressors of Stx2 at 8 hpi. These results indicate that the STEC CANARY biosensor assay is a rapid and sensitive assay applicable for detection of STEC contamination in food with minimal sample processing that can complement the current Food Safety Inspection Service (US) methodologies for STEC.","PeriodicalId":23119,"journal":{"name":"Toxins","volume":null,"pages":null},"PeriodicalIF":3.9000,"publicationDate":"2024-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid and Sensitive Detection of Shiga Toxin-Producing Escherichia coli (STEC) from Food Matrices Using the CANARY Biosensor Assay\",\"authors\":\"Christina C. Tam, Wen-Xian Du, Yangyang Wang, Andrew R. Flannery, Xiaohua He\",\"doi\":\"10.3390/toxins16070325\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Shiga toxin-producing Escherichia coli (STEC) causes a wide spectrum of diseases including hemorrhagic colitis and hemolytic uremic syndrome (HUS). Previously, we developed a rapid, sensitive, and potentially portable assay that identified STEC by detecting Shiga toxin (Stx) using a B-cell based biosensor platform. We applied this assay to detect Stx2 present in food samples that have been implicated in previous STEC foodborne outbreaks (milk, lettuce, and beef). The STEC enrichment medium, modified Tryptone Soy Broth (mTSB), inhibited the biosensor assay, but dilution with the assay buffer relieved this effect. Results with Stx2a toxoid-spiked food samples indicated an estimated limit of detection (LOD) of ≈4 ng/mL. When this assay was applied to food samples inoculated with STEC, it was able to detect 0.4 CFU/g or 0.4 CFU/mL of STEC at 16 h post incubation (hpi) in an enrichment medium containing mitomycin C. Importantly, this assay was even able to detect STEC strains that were high expressors of Stx2 at 8 hpi. These results indicate that the STEC CANARY biosensor assay is a rapid and sensitive assay applicable for detection of STEC contamination in food with minimal sample processing that can complement the current Food Safety Inspection Service (US) methodologies for STEC.\",\"PeriodicalId\":23119,\"journal\":{\"name\":\"Toxins\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Toxins\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/toxins16070325\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Toxins","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/toxins16070325","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
Rapid and Sensitive Detection of Shiga Toxin-Producing Escherichia coli (STEC) from Food Matrices Using the CANARY Biosensor Assay
Shiga toxin-producing Escherichia coli (STEC) causes a wide spectrum of diseases including hemorrhagic colitis and hemolytic uremic syndrome (HUS). Previously, we developed a rapid, sensitive, and potentially portable assay that identified STEC by detecting Shiga toxin (Stx) using a B-cell based biosensor platform. We applied this assay to detect Stx2 present in food samples that have been implicated in previous STEC foodborne outbreaks (milk, lettuce, and beef). The STEC enrichment medium, modified Tryptone Soy Broth (mTSB), inhibited the biosensor assay, but dilution with the assay buffer relieved this effect. Results with Stx2a toxoid-spiked food samples indicated an estimated limit of detection (LOD) of ≈4 ng/mL. When this assay was applied to food samples inoculated with STEC, it was able to detect 0.4 CFU/g or 0.4 CFU/mL of STEC at 16 h post incubation (hpi) in an enrichment medium containing mitomycin C. Importantly, this assay was even able to detect STEC strains that were high expressors of Stx2 at 8 hpi. These results indicate that the STEC CANARY biosensor assay is a rapid and sensitive assay applicable for detection of STEC contamination in food with minimal sample processing that can complement the current Food Safety Inspection Service (US) methodologies for STEC.
期刊介绍:
Toxins (ISSN 2072-6651) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to toxins and toxinology. It publishes reviews, regular research papers and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.