{"title":"绕场同步电机电容式功率传递耦合器的设计与测试","authors":"Rayane Hamidouche, Smail Mezani, Thierry Lubin, Tahar Hamiti","doi":"10.3233/jae-230245","DOIUrl":null,"url":null,"abstract":"This paper deals with the design and test of a contactless capacitive power converter operating at a frequency of 1 MHz, intended to supply the excitation winding of an 80 kW wound rotor synchronous machine. The methodology integrates the electromagnetic design of the rotor and its impact on the different parameters of the converter. To verify the validity of the concept, a first prototype was built by using surface-mounted capacitors grounded on the structure of a 1 MHz Class E resonant power converter. Then, a more representative capacitive contactless coupler was designed and implemented. Comparisons between simulation and experimental results have shown the limits of the proposed contactless power transmission. Special attention was paid on losses and efficiency which are crucial for this application.","PeriodicalId":50340,"journal":{"name":"International Journal of Applied Electromagnetics and Mechanics","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and test of capacitive power transfer coupling for wound field synchronous machines\",\"authors\":\"Rayane Hamidouche, Smail Mezani, Thierry Lubin, Tahar Hamiti\",\"doi\":\"10.3233/jae-230245\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the design and test of a contactless capacitive power converter operating at a frequency of 1 MHz, intended to supply the excitation winding of an 80 kW wound rotor synchronous machine. The methodology integrates the electromagnetic design of the rotor and its impact on the different parameters of the converter. To verify the validity of the concept, a first prototype was built by using surface-mounted capacitors grounded on the structure of a 1 MHz Class E resonant power converter. Then, a more representative capacitive contactless coupler was designed and implemented. Comparisons between simulation and experimental results have shown the limits of the proposed contactless power transmission. Special attention was paid on losses and efficiency which are crucial for this application.\",\"PeriodicalId\":50340,\"journal\":{\"name\":\"International Journal of Applied Electromagnetics and Mechanics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Electromagnetics and Mechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3233/jae-230245\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Electromagnetics and Mechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/jae-230245","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Design and test of capacitive power transfer coupling for wound field synchronous machines
This paper deals with the design and test of a contactless capacitive power converter operating at a frequency of 1 MHz, intended to supply the excitation winding of an 80 kW wound rotor synchronous machine. The methodology integrates the electromagnetic design of the rotor and its impact on the different parameters of the converter. To verify the validity of the concept, a first prototype was built by using surface-mounted capacitors grounded on the structure of a 1 MHz Class E resonant power converter. Then, a more representative capacitive contactless coupler was designed and implemented. Comparisons between simulation and experimental results have shown the limits of the proposed contactless power transmission. Special attention was paid on losses and efficiency which are crucial for this application.
期刊介绍:
The aim of the International Journal of Applied Electromagnetics and Mechanics is to contribute to intersciences coupling applied electromagnetics, mechanics and materials. The journal also intends to stimulate the further development of current technology in industry. The main subjects covered by the journal are:
Physics and mechanics of electromagnetic materials and devices
Computational electromagnetics in materials and devices
Applications of electromagnetic fields and materials
The three interrelated key subjects – electromagnetics, mechanics and materials - include the following aspects: electromagnetic NDE, electromagnetic machines and devices, electromagnetic materials and structures, electromagnetic fluids, magnetoelastic effects and magnetosolid mechanics, magnetic levitations, electromagnetic propulsion, bioelectromagnetics, and inverse problems in electromagnetics.
The editorial policy is to combine information and experience from both the latest high technology fields and as well as the well-established technologies within applied electromagnetics.