Akhmad Irhas Robby, Songling Jiang, Eun-Jung Jin, Sung Young Park
{"title":"基于过氧异构体β氧化基因敲除模型的骨关节炎电化学和荧光 MnO2 聚合物点电极传感器","authors":"Akhmad Irhas Robby, Songling Jiang, Eun-Jung Jin, Sung Young Park","doi":"10.3390/bios14070357","DOIUrl":null,"url":null,"abstract":"<p><p>A coenzyme A (CoA-SH)-responsive dual electrochemical and fluorescence-based sensor was designed utilizing an MnO<sub>2</sub>-immobilized-polymer-dot (MnO<sub>2</sub>@D-PD)-coated electrode for the sensitive detection of osteoarthritis (OA) in a peroxisomal β-oxidation knockout model. The CoA-SH-responsive MnO<sub>2</sub>@D-PD-coated electrode interacted sensitively with CoA-SH in OA chondrocytes, triggering electroconductivity and fluorescence changes due to cleavage of the MnO<sub>2</sub> nanosheet on the electrode. The MnO<sub>2</sub>@D-PD-coated electrode can detect CoA-SH in immature articular chondrocyte primary cells, as indicated by the significant increase in resistance in the control medium (R<sub>24h</sub> = 2.17 MΩ). This sensor also sensitively monitored the increase in resistance in chondrocyte cells in the presence of acetyl-CoA inducers, such as phytol (Phy) and sodium acetate (SA), in the medium (R<sub>24h</sub> = 2.67, 3.08 MΩ, respectively), compared to that in the control medium, demonstrating the detection efficiency of the sensor towards the increase in the CoA-SH concentration. Furthermore, fluorescence recovery was observed owing to MnO<sub>2</sub> cleavage, particularly in the Phy- and SA-supplemented media. The transcription levels of OA-related anabolic (<i>Acan</i>) and catabolic factors (<i>Adamts5</i>) in chondrocytes also confirmed the interaction between CoA-SH and the MnO<sub>2</sub>@D-PD-coated electrode. Additionally, electrode integration with a wireless sensing system provides inline monitoring via a smartphone, which can potentially be used for rapid and sensitive OA diagnosis.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"14 7","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11275033/pdf/","citationCount":"0","resultStr":"{\"title\":\"Electrochemical and Fluorescence MnO<sub>2</sub>-Polymer Dot Electrode Sensor for Osteoarthritis-Based Peroxisomal β-Oxidation Knockout Model.\",\"authors\":\"Akhmad Irhas Robby, Songling Jiang, Eun-Jung Jin, Sung Young Park\",\"doi\":\"10.3390/bios14070357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A coenzyme A (CoA-SH)-responsive dual electrochemical and fluorescence-based sensor was designed utilizing an MnO<sub>2</sub>-immobilized-polymer-dot (MnO<sub>2</sub>@D-PD)-coated electrode for the sensitive detection of osteoarthritis (OA) in a peroxisomal β-oxidation knockout model. The CoA-SH-responsive MnO<sub>2</sub>@D-PD-coated electrode interacted sensitively with CoA-SH in OA chondrocytes, triggering electroconductivity and fluorescence changes due to cleavage of the MnO<sub>2</sub> nanosheet on the electrode. The MnO<sub>2</sub>@D-PD-coated electrode can detect CoA-SH in immature articular chondrocyte primary cells, as indicated by the significant increase in resistance in the control medium (R<sub>24h</sub> = 2.17 MΩ). This sensor also sensitively monitored the increase in resistance in chondrocyte cells in the presence of acetyl-CoA inducers, such as phytol (Phy) and sodium acetate (SA), in the medium (R<sub>24h</sub> = 2.67, 3.08 MΩ, respectively), compared to that in the control medium, demonstrating the detection efficiency of the sensor towards the increase in the CoA-SH concentration. Furthermore, fluorescence recovery was observed owing to MnO<sub>2</sub> cleavage, particularly in the Phy- and SA-supplemented media. The transcription levels of OA-related anabolic (<i>Acan</i>) and catabolic factors (<i>Adamts5</i>) in chondrocytes also confirmed the interaction between CoA-SH and the MnO<sub>2</sub>@D-PD-coated electrode. Additionally, electrode integration with a wireless sensing system provides inline monitoring via a smartphone, which can potentially be used for rapid and sensitive OA diagnosis.</p>\",\"PeriodicalId\":48608,\"journal\":{\"name\":\"Biosensors-Basel\",\"volume\":\"14 7\",\"pages\":\"\"},\"PeriodicalIF\":4.9000,\"publicationDate\":\"2024-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11275033/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors-Basel\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bios14070357\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios14070357","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
摘要
利用MnO2-固定化聚合物点(MnO2@D-PD)涂层电极设计了一种基于电化学和荧光的辅酶A(CoA-SH)双响应传感器,用于在过氧化物酶体β氧化基因敲除模型中灵敏检测骨关节炎(OA)。CoA-SH响应型MnO2@D-PD涂层电极与OA软骨细胞中的CoA-SH灵敏地相互作用,由于电极上的MnO2纳米片的裂解而引发电导率和荧光变化。MnO2@D-PD涂层电极可以检测未成熟关节软骨细胞原代细胞中的CoA-SH,这表现在对照培养基中电阻的显著增加(R24h = 2.17 MΩ)。与对照培养基相比,该传感器还能灵敏监测培养基中存在乙酰-CoA 诱导剂(如植醇(Phy)和醋酸钠(SA))时软骨细胞电阻的增加(R24h = 2.67、3.08 MΩ),这表明传感器对 CoA-SH 浓度增加的检测效率很高。此外,由于 MnO2 的裂解,还观察到荧光恢复,尤其是在 Phy 和 SA 补充培养基中。软骨细胞中与 OA 相关的合成代谢因子(Acan)和分解代谢因子(Adamts5)的转录水平也证实了 CoA-SH 与 MnO2@D-PD 涂层电极之间的相互作用。此外,电极还与无线传感系统集成,可通过智能手机进行在线监测,从而有可能用于快速、灵敏的 OA 诊断。
Electrochemical and Fluorescence MnO2-Polymer Dot Electrode Sensor for Osteoarthritis-Based Peroxisomal β-Oxidation Knockout Model.
A coenzyme A (CoA-SH)-responsive dual electrochemical and fluorescence-based sensor was designed utilizing an MnO2-immobilized-polymer-dot (MnO2@D-PD)-coated electrode for the sensitive detection of osteoarthritis (OA) in a peroxisomal β-oxidation knockout model. The CoA-SH-responsive MnO2@D-PD-coated electrode interacted sensitively with CoA-SH in OA chondrocytes, triggering electroconductivity and fluorescence changes due to cleavage of the MnO2 nanosheet on the electrode. The MnO2@D-PD-coated electrode can detect CoA-SH in immature articular chondrocyte primary cells, as indicated by the significant increase in resistance in the control medium (R24h = 2.17 MΩ). This sensor also sensitively monitored the increase in resistance in chondrocyte cells in the presence of acetyl-CoA inducers, such as phytol (Phy) and sodium acetate (SA), in the medium (R24h = 2.67, 3.08 MΩ, respectively), compared to that in the control medium, demonstrating the detection efficiency of the sensor towards the increase in the CoA-SH concentration. Furthermore, fluorescence recovery was observed owing to MnO2 cleavage, particularly in the Phy- and SA-supplemented media. The transcription levels of OA-related anabolic (Acan) and catabolic factors (Adamts5) in chondrocytes also confirmed the interaction between CoA-SH and the MnO2@D-PD-coated electrode. Additionally, electrode integration with a wireless sensing system provides inline monitoring via a smartphone, which can potentially be used for rapid and sensitive OA diagnosis.
Biosensors-BaselBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍:
Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.