{"title":"开发和验证用于血清中重组人源化抗IL-4Rα单克隆抗体CM310定量的酶联免疫吸附测定及其在Sprague-Dawley大鼠药代动力学研究中的应用。","authors":"Yimeng Hao , Libo Zhang , Qinghe Meng , Qian Jia , Jing Ma , Xuemei Zhang","doi":"10.1016/j.ab.2024.115623","DOIUrl":null,"url":null,"abstract":"<div><p>CM310 is a recombinant humanized monoclonal antibody targeting Interleukin (IL)-4 receptor alpha (IL-4Rα). IL-4Rα blockade prevents IL-4 and IL-13 from binding to their receptor, thereby inhibiting downstream signaling pathways that drive Type 2 helper T-cell (Th2) inflammation. CM310 holds potential for treating Th2-related inflammatory diseases, such as asthma, atopic dermatitis and chronic sinusitis with nasal polyposis. In this study, a direct enzyme-linked immunosorbent assay (ELISA) was developed to measure the concentrations of CM310 in rat serum. Seven calibration standards (ranging from 25 to 1600 ng/mL) and three quality controls (70, 500 and 1250 ng/mL) were defined. The limit of detection (LOD), lower limit of quantification (LLOQ) and upper limit of quantification (ULOQ) were 13, 25 and 1600 ng/mL, respectively. The method exhibited excellent precision and accuracy and successfully applied to <em>in vitro</em> serum stability and pharmacokinetic (PK) studies. In conclusion, we have developed and validated a highly sensitive and selective method for measuring CM310 in Sprague-Dawley rats. The development and validation ELISA method met the acceptable criteria, which suggested that these can be applied to quantify CM310, as well as in PK studies.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and validation of an enzyme-linked immunosorbent assay for the quantification of a recombinant humanized anti-IL-4Rα monoclonal antibody CM310 in serum and its application to pharmacokinetic study in Sprague-Dawley Rats\",\"authors\":\"Yimeng Hao , Libo Zhang , Qinghe Meng , Qian Jia , Jing Ma , Xuemei Zhang\",\"doi\":\"10.1016/j.ab.2024.115623\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>CM310 is a recombinant humanized monoclonal antibody targeting Interleukin (IL)-4 receptor alpha (IL-4Rα). IL-4Rα blockade prevents IL-4 and IL-13 from binding to their receptor, thereby inhibiting downstream signaling pathways that drive Type 2 helper T-cell (Th2) inflammation. CM310 holds potential for treating Th2-related inflammatory diseases, such as asthma, atopic dermatitis and chronic sinusitis with nasal polyposis. In this study, a direct enzyme-linked immunosorbent assay (ELISA) was developed to measure the concentrations of CM310 in rat serum. Seven calibration standards (ranging from 25 to 1600 ng/mL) and three quality controls (70, 500 and 1250 ng/mL) were defined. The limit of detection (LOD), lower limit of quantification (LLOQ) and upper limit of quantification (ULOQ) were 13, 25 and 1600 ng/mL, respectively. The method exhibited excellent precision and accuracy and successfully applied to <em>in vitro</em> serum stability and pharmacokinetic (PK) studies. In conclusion, we have developed and validated a highly sensitive and selective method for measuring CM310 in Sprague-Dawley rats. The development and validation ELISA method met the acceptable criteria, which suggested that these can be applied to quantify CM310, as well as in PK studies.</p></div>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0003269724001672\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003269724001672","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Development and validation of an enzyme-linked immunosorbent assay for the quantification of a recombinant humanized anti-IL-4Rα monoclonal antibody CM310 in serum and its application to pharmacokinetic study in Sprague-Dawley Rats
CM310 is a recombinant humanized monoclonal antibody targeting Interleukin (IL)-4 receptor alpha (IL-4Rα). IL-4Rα blockade prevents IL-4 and IL-13 from binding to their receptor, thereby inhibiting downstream signaling pathways that drive Type 2 helper T-cell (Th2) inflammation. CM310 holds potential for treating Th2-related inflammatory diseases, such as asthma, atopic dermatitis and chronic sinusitis with nasal polyposis. In this study, a direct enzyme-linked immunosorbent assay (ELISA) was developed to measure the concentrations of CM310 in rat serum. Seven calibration standards (ranging from 25 to 1600 ng/mL) and three quality controls (70, 500 and 1250 ng/mL) were defined. The limit of detection (LOD), lower limit of quantification (LLOQ) and upper limit of quantification (ULOQ) were 13, 25 and 1600 ng/mL, respectively. The method exhibited excellent precision and accuracy and successfully applied to in vitro serum stability and pharmacokinetic (PK) studies. In conclusion, we have developed and validated a highly sensitive and selective method for measuring CM310 in Sprague-Dawley rats. The development and validation ELISA method met the acceptable criteria, which suggested that these can be applied to quantify CM310, as well as in PK studies.