用紫光或蓝光 LED 光激活不同浓度过氧化氢的美白效果和牙齿敏感性的临床比较。

IF 2.1 4区 医学 Q3 ENGINEERING, BIOMEDICAL Lasers in Medical Science Pub Date : 2024-07-26 DOI:10.1007/s10103-024-04144-6
Maria Gabriela Veiga Vidal de Oliveira, Daniel José Braga Dutra, Joatan Lucas de Sousa Gomes Costa, João Felipe Besegato, Antonia Patricia Oliveira Barros, Ricardo Reis Oliveira, Patricia Valente Araújo, Hugo Henriques Alvim
{"title":"用紫光或蓝光 LED 光激活不同浓度过氧化氢的美白效果和牙齿敏感性的临床比较。","authors":"Maria Gabriela Veiga Vidal de Oliveira, Daniel José Braga Dutra, Joatan Lucas de Sousa Gomes Costa, João Felipe Besegato, Antonia Patricia Oliveira Barros, Ricardo Reis Oliveira, Patricia Valente Araújo, Hugo Henriques Alvim","doi":"10.1007/s10103-024-04144-6","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the photoactivation of hydrogen peroxide gels at different concentrations using blue or violet LED in terms of whitening efficacy and tooth sensitivity. Forty patients were randomly divided into 4 groups: HP6V (violet LED and 6% hydrogen peroxide), HP6B (blue LED and 6% hydrogen peroxide), HP35V (violet LED and 35% hydrogen peroxide), and HP35B (blue LED and 35% hydrogen peroxide). The L*, a* and b* values were measured before, 1 week and 3 months after treatment, and the ΔE and ΔW<sub>ID</sub> values were calculated. Tooth sensitivity was measured using a visual analogue scale (VAS) before, immediately after, and 24 h after bleaching. The ΔE, ΔW<sub>ID</sub> and bleaching sensitivity values were subjected to the ANOVA test and Bonferroni post-test. HP35V and HP35B showed higher whitening efficacy than HP6VL, while HP6V did not show statistical differences compared to the other groups. Regarding bleaching-related sensitivity, the HP6V and HP6B groups presented the lowest values when compared to HP35V and HP35B. HP6V showed whitening efficacy comparable to HP35V and HP35B but with reduced tooth sensitivity. TRIAL REGISTRATION NUMBER: NCT06165458; registration date: 12/09/2023.</p>","PeriodicalId":17978,"journal":{"name":"Lasers in Medical Science","volume":"39 1","pages":"195"},"PeriodicalIF":2.1000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical comparison of whitening efficacy and tooth sensitivity of different concentrations of hydrogen peroxide photoactivated with violet or blue LEDs.\",\"authors\":\"Maria Gabriela Veiga Vidal de Oliveira, Daniel José Braga Dutra, Joatan Lucas de Sousa Gomes Costa, João Felipe Besegato, Antonia Patricia Oliveira Barros, Ricardo Reis Oliveira, Patricia Valente Araújo, Hugo Henriques Alvim\",\"doi\":\"10.1007/s10103-024-04144-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluated the photoactivation of hydrogen peroxide gels at different concentrations using blue or violet LED in terms of whitening efficacy and tooth sensitivity. Forty patients were randomly divided into 4 groups: HP6V (violet LED and 6% hydrogen peroxide), HP6B (blue LED and 6% hydrogen peroxide), HP35V (violet LED and 35% hydrogen peroxide), and HP35B (blue LED and 35% hydrogen peroxide). The L*, a* and b* values were measured before, 1 week and 3 months after treatment, and the ΔE and ΔW<sub>ID</sub> values were calculated. Tooth sensitivity was measured using a visual analogue scale (VAS) before, immediately after, and 24 h after bleaching. The ΔE, ΔW<sub>ID</sub> and bleaching sensitivity values were subjected to the ANOVA test and Bonferroni post-test. HP35V and HP35B showed higher whitening efficacy than HP6VL, while HP6V did not show statistical differences compared to the other groups. Regarding bleaching-related sensitivity, the HP6V and HP6B groups presented the lowest values when compared to HP35V and HP35B. HP6V showed whitening efficacy comparable to HP35V and HP35B but with reduced tooth sensitivity. TRIAL REGISTRATION NUMBER: NCT06165458; registration date: 12/09/2023.</p>\",\"PeriodicalId\":17978,\"journal\":{\"name\":\"Lasers in Medical Science\",\"volume\":\"39 1\",\"pages\":\"195\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lasers in Medical Science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10103-024-04144-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lasers in Medical Science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10103-024-04144-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究评估了使用蓝光或紫光 LED 对不同浓度的过氧化氢凝胶进行光激活后的美白效果和牙齿敏感性。40 名患者被随机分为 4 组:HP6V(紫光 LED 和 6% 过氧化氢)、HP6B(蓝光 LED 和 6% 过氧化氢)、HP35V(紫光 LED 和 35% 过氧化氢)和 HP35B(蓝光 LED 和 35% 过氧化氢)。分别在治疗前、治疗后 1 周和 3 个月测量了 L*、a* 和 b*值,并计算了 ΔE 和 ΔWID 值。牙齿敏感度在漂白前、漂白后和漂白后 24 小时内使用视觉模拟量表(VAS)进行测量。ΔE、ΔWID 和漂白敏感度值经过方差分析和 Bonferroni 后检验。HP35V和HP35B的美白效果高于HP6VL,而HP6V与其他组相比没有统计学差异。在漂白相关敏感度方面,HP6V 和 HP6B 组与 HP35V 和 HP35B 组相比数值最低。HP6V的美白效果与HP35V和HP35B相当,但牙齿敏感度有所降低。试验注册编号:NCT06165458;注册日期:2023 年 9 月 12 日。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical comparison of whitening efficacy and tooth sensitivity of different concentrations of hydrogen peroxide photoactivated with violet or blue LEDs.

This study evaluated the photoactivation of hydrogen peroxide gels at different concentrations using blue or violet LED in terms of whitening efficacy and tooth sensitivity. Forty patients were randomly divided into 4 groups: HP6V (violet LED and 6% hydrogen peroxide), HP6B (blue LED and 6% hydrogen peroxide), HP35V (violet LED and 35% hydrogen peroxide), and HP35B (blue LED and 35% hydrogen peroxide). The L*, a* and b* values were measured before, 1 week and 3 months after treatment, and the ΔE and ΔWID values were calculated. Tooth sensitivity was measured using a visual analogue scale (VAS) before, immediately after, and 24 h after bleaching. The ΔE, ΔWID and bleaching sensitivity values were subjected to the ANOVA test and Bonferroni post-test. HP35V and HP35B showed higher whitening efficacy than HP6VL, while HP6V did not show statistical differences compared to the other groups. Regarding bleaching-related sensitivity, the HP6V and HP6B groups presented the lowest values when compared to HP35V and HP35B. HP6V showed whitening efficacy comparable to HP35V and HP35B but with reduced tooth sensitivity. TRIAL REGISTRATION NUMBER: NCT06165458; registration date: 12/09/2023.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lasers in Medical Science
Lasers in Medical Science 医学-工程:生物医学
CiteScore
4.50
自引率
4.80%
发文量
192
审稿时长
3-8 weeks
期刊介绍: Lasers in Medical Science (LIMS) has established itself as the leading international journal in the rapidly expanding field of medical and dental applications of lasers and light. It provides a forum for the publication of papers on the technical, experimental, and clinical aspects of the use of medical lasers, including lasers in surgery, endoscopy, angioplasty, hyperthermia of tumors, and photodynamic therapy. In addition to medical laser applications, LIMS presents high-quality manuscripts on a wide range of dental topics, including aesthetic dentistry, endodontics, orthodontics, and prosthodontics. The journal publishes articles on the medical and dental applications of novel laser technologies, light delivery systems, sensors to monitor laser effects, basic laser-tissue interactions, and the modeling of laser-tissue interactions. Beyond laser applications, LIMS features articles relating to the use of non-laser light-tissue interactions.
期刊最新文献
Does the holmium laser have a place in the treatment of pilonidal cysts? (Pilolas study). Effects of femtosecond laser on hard dental tissues: A scoping review. Comparative evaluation of healing using Er, Cr: YSGG laser treatment with conventional method after extraction of permanent teeth: an in-vivo study. Photobiomodulation in recurrent aphthous stomatitis management using three different laser wavelengths. A randomized clinical trial. Effect of photobiomodulation and corticopuncture methods on tooth displacement and gene expression: animal study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1