S. Bosonnet, X. Huang, L. Bataillou, L. Martinelli, Paul C. M. Fossati, Laurence Latu-Romain, Yves Wouters, C. Desgranges, D. Monceau
{"title":"Ni-30Cr 合金在低温和低氧分压下的氧化:改进动力学常数测定的实验方法","authors":"S. Bosonnet, X. Huang, L. Bataillou, L. Martinelli, Paul C. M. Fossati, Laurence Latu-Romain, Yves Wouters, C. Desgranges, D. Monceau","doi":"10.1007/s11085-024-10270-x","DOIUrl":null,"url":null,"abstract":"<div><p>Ni–30Cr model alloy was used to study chromia-scale formation behaviour. During its formation the mass variation signal is weak and it is important to take specific care to measure oxidation kinetics by thermogravimetric analysis. Symmetrical design allows the determination of very small mass changes in compensating buoyancy effects and limiting measurement drift. The mass variation measurement comprises noise coming from different sources that affects the electronic signal. It must be minimised to improve accuracy. This involves keeping the room-temperature constant, strictly balancing the beam and minimising buoyancy effects. By this way it was possible to acquire kinetics and to measured rate constants, <i>k</i><sub><i>p</i></sub>, in a range from 3.10<sup>–5</sup> to 3.10<sup>–10</sup> mg<sup>2</sup>.cm<sup>−4</sup>.s<sup>−1</sup> equivalent to 10<sup>–12</sup> down to 10<sup>–17</sup> cm<sup>2</sup>.s<sup>−1</sup>. Oxygen partial pressure (<span>\\({P}_{{O}_{2}}\\)</span>) was monitor and revealed an abnormal consumption of oxygen at the beginning of the thermal exposure. Experiments with an inert material showed parasitic reactions identified by mass spectrometry as combustion of impurities. As oxygen consumption is not only due to oxidation of the sample, corrosion kinetics can’t be deduced from it. Hence, to determine whether the oxygen supply from the gas is a limiting parameter, a model, which quantifies oxygen consumption by sample oxidation within the thermobalance, is proposed.</p></div>","PeriodicalId":724,"journal":{"name":"Oxidation of Metals","volume":"101 5","pages":"1197 - 1209"},"PeriodicalIF":2.1000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11085-024-10270-x.pdf","citationCount":"0","resultStr":"{\"title\":\"Oxidation of Ni–30Cr Alloy at Low Temperature and Low Oxygen Partial Pressure: Experimental Methods to Improve Kinetics Constants Determination\",\"authors\":\"S. Bosonnet, X. Huang, L. Bataillou, L. Martinelli, Paul C. M. Fossati, Laurence Latu-Romain, Yves Wouters, C. Desgranges, D. Monceau\",\"doi\":\"10.1007/s11085-024-10270-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Ni–30Cr model alloy was used to study chromia-scale formation behaviour. During its formation the mass variation signal is weak and it is important to take specific care to measure oxidation kinetics by thermogravimetric analysis. Symmetrical design allows the determination of very small mass changes in compensating buoyancy effects and limiting measurement drift. The mass variation measurement comprises noise coming from different sources that affects the electronic signal. It must be minimised to improve accuracy. This involves keeping the room-temperature constant, strictly balancing the beam and minimising buoyancy effects. By this way it was possible to acquire kinetics and to measured rate constants, <i>k</i><sub><i>p</i></sub>, in a range from 3.10<sup>–5</sup> to 3.10<sup>–10</sup> mg<sup>2</sup>.cm<sup>−4</sup>.s<sup>−1</sup> equivalent to 10<sup>–12</sup> down to 10<sup>–17</sup> cm<sup>2</sup>.s<sup>−1</sup>. Oxygen partial pressure (<span>\\\\({P}_{{O}_{2}}\\\\)</span>) was monitor and revealed an abnormal consumption of oxygen at the beginning of the thermal exposure. Experiments with an inert material showed parasitic reactions identified by mass spectrometry as combustion of impurities. As oxygen consumption is not only due to oxidation of the sample, corrosion kinetics can’t be deduced from it. Hence, to determine whether the oxygen supply from the gas is a limiting parameter, a model, which quantifies oxygen consumption by sample oxidation within the thermobalance, is proposed.</p></div>\",\"PeriodicalId\":724,\"journal\":{\"name\":\"Oxidation of Metals\",\"volume\":\"101 5\",\"pages\":\"1197 - 1209\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s11085-024-10270-x.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oxidation of Metals\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s11085-024-10270-x\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"METALLURGY & METALLURGICAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oxidation of Metals","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s11085-024-10270-x","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
Oxidation of Ni–30Cr Alloy at Low Temperature and Low Oxygen Partial Pressure: Experimental Methods to Improve Kinetics Constants Determination
Ni–30Cr model alloy was used to study chromia-scale formation behaviour. During its formation the mass variation signal is weak and it is important to take specific care to measure oxidation kinetics by thermogravimetric analysis. Symmetrical design allows the determination of very small mass changes in compensating buoyancy effects and limiting measurement drift. The mass variation measurement comprises noise coming from different sources that affects the electronic signal. It must be minimised to improve accuracy. This involves keeping the room-temperature constant, strictly balancing the beam and minimising buoyancy effects. By this way it was possible to acquire kinetics and to measured rate constants, kp, in a range from 3.10–5 to 3.10–10 mg2.cm−4.s−1 equivalent to 10–12 down to 10–17 cm2.s−1. Oxygen partial pressure (\({P}_{{O}_{2}}\)) was monitor and revealed an abnormal consumption of oxygen at the beginning of the thermal exposure. Experiments with an inert material showed parasitic reactions identified by mass spectrometry as combustion of impurities. As oxygen consumption is not only due to oxidation of the sample, corrosion kinetics can’t be deduced from it. Hence, to determine whether the oxygen supply from the gas is a limiting parameter, a model, which quantifies oxygen consumption by sample oxidation within the thermobalance, is proposed.
期刊介绍:
Oxidation of Metals is the premier source for the rapid dissemination of current research on all aspects of the science of gas-solid reactions at temperatures greater than about 400˚C, with primary focus on the high-temperature corrosion of bulk and coated systems. This authoritative bi-monthly publishes original scientific papers on kinetics, mechanisms, studies of scales from structural and morphological viewpoints, transport properties in scales, phase-boundary reactions, and much more. Articles may discuss both theoretical and experimental work related to gas-solid reactions at the surface or near-surface of a material exposed to elevated temperatures, including reactions with oxygen, nitrogen, sulfur, carbon and halogens. In addition, Oxidation of Metals publishes the results of frontier research concerned with deposit-induced attack. Review papers and short technical notes are encouraged.