榛子核仁中总α放射性水平的测量和年有效剂量的估算

IF 1.4 3区 化学 Q4 CHEMISTRY, INORGANIC & NUCLEAR Radiochimica Acta Pub Date : 2024-07-22 DOI:10.1515/ract-2023-0224
Gözde Tektaş, Buket Canbaz Öztürk
{"title":"榛子核仁中总α放射性水平的测量和年有效剂量的估算","authors":"Gözde Tektaş, Buket Canbaz Öztürk","doi":"10.1515/ract-2023-0224","DOIUrl":null,"url":null,"abstract":"The present study investigates gross alpha (GA) radioactivity levels in hazelnut kernels purchased from markets in Türkiye. 10 different hazelnut samples were crushed and made ready for counting. The alpha counts were obtained via ELSEC 7286 low level alpha counter with ZnS scintillator and EMI 6097B photomultiplier tube. The samples were placed in front of the detector to acquire the counts. All samples were counted isochronously. In addition to the GA activity measurement, total annual effective dose (AED) value for different age groups owing to ingestion was calculated for each sample. It was observed that the GA radioactivity levels in the samples were quite low, and total AED values were considerably lower than the WHO worldwide average AED value (290 μSv/year).","PeriodicalId":21167,"journal":{"name":"Radiochimica Acta","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of gross alpha radioactivity levels and estimation of annual effective dose in hazelnut kernels\",\"authors\":\"Gözde Tektaş, Buket Canbaz Öztürk\",\"doi\":\"10.1515/ract-2023-0224\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present study investigates gross alpha (GA) radioactivity levels in hazelnut kernels purchased from markets in Türkiye. 10 different hazelnut samples were crushed and made ready for counting. The alpha counts were obtained via ELSEC 7286 low level alpha counter with ZnS scintillator and EMI 6097B photomultiplier tube. The samples were placed in front of the detector to acquire the counts. All samples were counted isochronously. In addition to the GA activity measurement, total annual effective dose (AED) value for different age groups owing to ingestion was calculated for each sample. It was observed that the GA radioactivity levels in the samples were quite low, and total AED values were considerably lower than the WHO worldwide average AED value (290 μSv/year).\",\"PeriodicalId\":21167,\"journal\":{\"name\":\"Radiochimica Acta\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiochimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1515/ract-2023-0224\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiochimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1515/ract-2023-0224","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

本研究调查了从土耳其市场上购买的榛子核仁中的总α(GA)放射性水平。10 个不同的榛子样本被粉碎并准备进行计数。α计数是通过配有 ZnS 闪烁器和 EMI 6097B 光电倍增管的 ELSEC 7286 低浓度α计数器获得的。将样品放在探测器前进行计数。所有样品都是等时计数。除了测量γ-氨基甲酸乙酯的放射性活度外,还计算了每个样本在不同年 龄组别摄入γ-氨基甲酸乙酯后每年的总有效剂量值。结果显示,样本的γ-基因活度水平相当低,而总有效剂量值则大大低于世界卫生组织的全球平均有效剂量值(290 微希/年)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement of gross alpha radioactivity levels and estimation of annual effective dose in hazelnut kernels
The present study investigates gross alpha (GA) radioactivity levels in hazelnut kernels purchased from markets in Türkiye. 10 different hazelnut samples were crushed and made ready for counting. The alpha counts were obtained via ELSEC 7286 low level alpha counter with ZnS scintillator and EMI 6097B photomultiplier tube. The samples were placed in front of the detector to acquire the counts. All samples were counted isochronously. In addition to the GA activity measurement, total annual effective dose (AED) value for different age groups owing to ingestion was calculated for each sample. It was observed that the GA radioactivity levels in the samples were quite low, and total AED values were considerably lower than the WHO worldwide average AED value (290 μSv/year).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiochimica Acta
Radiochimica Acta 化学-核科学技术
CiteScore
2.90
自引率
16.70%
发文量
78
审稿时长
6 months
期刊介绍: Radiochimica Acta publishes manuscripts encompassing chemical aspects of nuclear science and technology.
期刊最新文献
In vivo evaluation of Cerenkov luminescence and SPECT imaging for nanoscale 177Lu-labeled metal-organic framework Study on separation of ReO4 −, a substitute for TcO4 −, using functional ionic liquid impregnated extraction chromatography resins [113mIn]In-PSMA: high potential agent for SPECT imaging of prostate cancer Effect of ZnO particle size on the radiation shielding efficiency of B2O3–BaO–ZnO glass system Development of gelatin nanoparticles for positron emission tomography diagnosis in pancreatic cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1