{"title":"使用人工神经网络模型和降序模型评估压缩机性能预测模型","authors":"Hosik Jeong, Kanghyuk Ko, Junsung Kim, Jongsoo Kim, Seongyong Eom, Sang-Kwon Na, Gyungmin Choi","doi":"10.3390/en17153686","DOIUrl":null,"url":null,"abstract":"In order to save the time and material costs associated with refrigeration system performance evaluations, a reduced-order model (ROM) using highly accurate numerical analysis results and some experimental values was developed. To solve the shortcomings of these traditional methods in monitoring complex systems, a simplified reduced-order system model was developed. To evaluate the performance of the refrigeration system compressor, the temperature of several points in the system where the compressor actually operates was measured, and the measured values were used as input values for ROM development. A lot of raw data to develop a highly accurate ROM were acquired from a VRF system installed in a building for one year, and in this study, specific operating conditions were selected and used as input values. In this study, the ROM development process can predict the performance of compressors used in air conditioning systems, and the research results on optimizing input data required for ROM generation were observed. The input data are arranged according to the design of experiments (DOE), and the accuracy of ROM according to data arrangement is compared through the experiment results.","PeriodicalId":11557,"journal":{"name":"Energies","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Prediction Model for Compressor Performance Using Artificial Neural Network Models and Reduced-Order Models\",\"authors\":\"Hosik Jeong, Kanghyuk Ko, Junsung Kim, Jongsoo Kim, Seongyong Eom, Sang-Kwon Na, Gyungmin Choi\",\"doi\":\"10.3390/en17153686\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to save the time and material costs associated with refrigeration system performance evaluations, a reduced-order model (ROM) using highly accurate numerical analysis results and some experimental values was developed. To solve the shortcomings of these traditional methods in monitoring complex systems, a simplified reduced-order system model was developed. To evaluate the performance of the refrigeration system compressor, the temperature of several points in the system where the compressor actually operates was measured, and the measured values were used as input values for ROM development. A lot of raw data to develop a highly accurate ROM were acquired from a VRF system installed in a building for one year, and in this study, specific operating conditions were selected and used as input values. In this study, the ROM development process can predict the performance of compressors used in air conditioning systems, and the research results on optimizing input data required for ROM generation were observed. The input data are arranged according to the design of experiments (DOE), and the accuracy of ROM according to data arrangement is compared through the experiment results.\",\"PeriodicalId\":11557,\"journal\":{\"name\":\"Energies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energies\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/en17153686\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energies","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/en17153686","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

为了节省与制冷系统性能评估相关的时间和材料成本,利用高精度的数值分析结果和一些实验值开发了一种简化阶模型(ROM)。为了解决这些传统方法在监测复杂系统方面的不足,我们开发了一个简化的降阶系统模型。为了评估制冷系统压缩机的性能,对系统中压缩机实际运行的几个点的温度进行了测量,并将测量值作为 ROM 开发的输入值。从安装在一栋建筑中一年的 VRF 系统中获取了大量用于开发高精度 ROM 的原始数据,并在本研究中选择了特定的运行条件作为输入值。在这项研究中,ROM 的开发过程可以预测空调系统中使用的压缩机的性能,并观察了生成 ROM 所需的输入数据的优化研究成果。根据实验设计(DOE)安排输入数据,并通过实验结果比较根据数据安排生成的 ROM 的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Prediction Model for Compressor Performance Using Artificial Neural Network Models and Reduced-Order Models
In order to save the time and material costs associated with refrigeration system performance evaluations, a reduced-order model (ROM) using highly accurate numerical analysis results and some experimental values was developed. To solve the shortcomings of these traditional methods in monitoring complex systems, a simplified reduced-order system model was developed. To evaluate the performance of the refrigeration system compressor, the temperature of several points in the system where the compressor actually operates was measured, and the measured values were used as input values for ROM development. A lot of raw data to develop a highly accurate ROM were acquired from a VRF system installed in a building for one year, and in this study, specific operating conditions were selected and used as input values. In this study, the ROM development process can predict the performance of compressors used in air conditioning systems, and the research results on optimizing input data required for ROM generation were observed. The input data are arranged according to the design of experiments (DOE), and the accuracy of ROM according to data arrangement is compared through the experiment results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Energies
Energies ENERGY & FUELS-
CiteScore
6.20
自引率
21.90%
发文量
8045
审稿时长
1.9 months
期刊介绍: Energies (ISSN 1996-1073) is an open access journal of related scientific research, technology development and policy and management studies. It publishes reviews, regular research papers, and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
期刊最新文献
Transforming Abandoned Hydrocarbon Fields into Heat Storage Solutions: A Hungarian Case Study Using Enhanced Multi-Criteria Decision Analysis–Analytic Hierarchy Process and Geostatistical Methods Bibliometric Analysis of Multi-Criteria Decision-Making (MCDM) Methods in Environmental and Energy Engineering Using CiteSpace Software: Identification of Key Research Trends and Patterns of International Cooperation Readiness of Malaysian PV System to Utilize Energy Storage System with Second-Life Electric Vehicle Batteries Optimal Configuration Method of Primary and Secondary Integrated Intelligent Switches in the Active Distribution Network Considering Comprehensive Fault Observability Effect of Exhaust Gas Recirculation on Combustion Characteristics of Ultra-Low-Sulfur Diesel in Conventional and PPCI Regimes for a High-Compression-Ratio Engine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1