{"title":"单相在线交互式不间断电源设计","authors":"Zhiling Xu, Zhuoqi Zhang, Rui Ren, Wenhao Wang","doi":"10.54254/2755-2721/78/20240537","DOIUrl":null,"url":null,"abstract":"The single-phase on-line interactive uninterruptible power supply (UPS) designed in this paper consists of three circuits, namely, a single-phase power factor correction circuit, a single-phase inverter circuit, and a bi-directional DC/DC circuit, each of which contains a main circuit as well as a control circuit. The principle, parameter design and control circuit design of each circuit are briefly described. The simulation model of the UPS is constructed, and the simulation results in normal and abnormal utility power are given to verify the correctness of the design.","PeriodicalId":502253,"journal":{"name":"Applied and Computational Engineering","volume":"34 44","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-phase online interactive uninterruptible power supply design\",\"authors\":\"Zhiling Xu, Zhuoqi Zhang, Rui Ren, Wenhao Wang\",\"doi\":\"10.54254/2755-2721/78/20240537\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The single-phase on-line interactive uninterruptible power supply (UPS) designed in this paper consists of three circuits, namely, a single-phase power factor correction circuit, a single-phase inverter circuit, and a bi-directional DC/DC circuit, each of which contains a main circuit as well as a control circuit. The principle, parameter design and control circuit design of each circuit are briefly described. The simulation model of the UPS is constructed, and the simulation results in normal and abnormal utility power are given to verify the correctness of the design.\",\"PeriodicalId\":502253,\"journal\":{\"name\":\"Applied and Computational Engineering\",\"volume\":\"34 44\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied and Computational Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54254/2755-2721/78/20240537\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied and Computational Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54254/2755-2721/78/20240537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Single-phase online interactive uninterruptible power supply design
The single-phase on-line interactive uninterruptible power supply (UPS) designed in this paper consists of three circuits, namely, a single-phase power factor correction circuit, a single-phase inverter circuit, and a bi-directional DC/DC circuit, each of which contains a main circuit as well as a control circuit. The principle, parameter design and control circuit design of each circuit are briefly described. The simulation model of the UPS is constructed, and the simulation results in normal and abnormal utility power are given to verify the correctness of the design.