{"title":"二尖瓣主动脉瓣疾病患者心电图的预后价值","authors":"Paul M. Hendriks , Zoë A. Keuning , Jan A. Kors , Allard T. van den Hoven , Laurie W. Geenen , Jannet A. Eindhoven , Vivan J.M. Baggen , Judith A.A.E. Cuypers , Robert M. Kauling , Jolien W. Roos-Hesselink , Annemien E. van den Bosch","doi":"10.1016/j.jelectrocard.2024.153760","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Identifying bicuspid aortic valve (BAV) patients at risk for cardiac events remains challenging and the role of the electrocardiogram (ECG) has not yet been described. Therefore, this study aims to describe ECG parameters in BAV patients, and investigate their prognostic value.</p></div><div><h3>Methods</h3><p>In this single-center prospective study patients with BAV without a prior aortic valve replacement (AVR) were included. Transthoracic echocardiogram and 12‑lead resting-ECG were obtained. Associations between ECG parameters and the composite endpoint of all-cause mortality and AVR were assessed using Cox-proportional hazard analysis.</p></div><div><h3>Results</h3><p>120 patients with BAV were included (median age 30 years, 61% male). Median aortic jet velocity was 2.4 m/s [IQR: 1.7–3.4] and 5 patients (4%) had severe aortic regurgitation. All patients were in sinus rhythm. Any ECG abnormality was present in 57 patients (48%). Median PR-interval was 156 [IQR: 138–170] msec. A deviating QRS axis was found in 17 patients (14%) and Cornell criteria for LVH were fulfilled in 20 patients (17%). Repolarization abnormalities were present in 12 patients (10%). Median follow-up duration was 7.0 [6.3–9.8] years, during which 23 patients underwent AVR and 2 patients died. After adjusting for age, a longer PR-interval was associated with worse intervention-free survival (HR 1.02, 95% CI: 1.01–1.04).</p></div><div><h3>Conclusion</h3><p>Almost half of the patients with BAV had abnormalities on their ECG. Moreover, the PR-interval may be an interesting prognostic marker for intervention-free survival in BAV patients.</p></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0022073624002309/pdfft?md5=1390aba17af0b5c5e675bb174af2803b&pid=1-s2.0-S0022073624002309-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Prognostic value of the electrocardiogram in patients with bicuspid aortic valve disease\",\"authors\":\"Paul M. Hendriks , Zoë A. Keuning , Jan A. Kors , Allard T. van den Hoven , Laurie W. Geenen , Jannet A. Eindhoven , Vivan J.M. Baggen , Judith A.A.E. Cuypers , Robert M. Kauling , Jolien W. Roos-Hesselink , Annemien E. van den Bosch\",\"doi\":\"10.1016/j.jelectrocard.2024.153760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Identifying bicuspid aortic valve (BAV) patients at risk for cardiac events remains challenging and the role of the electrocardiogram (ECG) has not yet been described. Therefore, this study aims to describe ECG parameters in BAV patients, and investigate their prognostic value.</p></div><div><h3>Methods</h3><p>In this single-center prospective study patients with BAV without a prior aortic valve replacement (AVR) were included. Transthoracic echocardiogram and 12‑lead resting-ECG were obtained. Associations between ECG parameters and the composite endpoint of all-cause mortality and AVR were assessed using Cox-proportional hazard analysis.</p></div><div><h3>Results</h3><p>120 patients with BAV were included (median age 30 years, 61% male). Median aortic jet velocity was 2.4 m/s [IQR: 1.7–3.4] and 5 patients (4%) had severe aortic regurgitation. All patients were in sinus rhythm. Any ECG abnormality was present in 57 patients (48%). Median PR-interval was 156 [IQR: 138–170] msec. A deviating QRS axis was found in 17 patients (14%) and Cornell criteria for LVH were fulfilled in 20 patients (17%). Repolarization abnormalities were present in 12 patients (10%). Median follow-up duration was 7.0 [6.3–9.8] years, during which 23 patients underwent AVR and 2 patients died. After adjusting for age, a longer PR-interval was associated with worse intervention-free survival (HR 1.02, 95% CI: 1.01–1.04).</p></div><div><h3>Conclusion</h3><p>Almost half of the patients with BAV had abnormalities on their ECG. Moreover, the PR-interval may be an interesting prognostic marker for intervention-free survival in BAV patients.</p></div>\",\"PeriodicalId\":15606,\"journal\":{\"name\":\"Journal of electrocardiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0022073624002309/pdfft?md5=1390aba17af0b5c5e675bb174af2803b&pid=1-s2.0-S0022073624002309-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of electrocardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022073624002309\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073624002309","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Prognostic value of the electrocardiogram in patients with bicuspid aortic valve disease
Background
Identifying bicuspid aortic valve (BAV) patients at risk for cardiac events remains challenging and the role of the electrocardiogram (ECG) has not yet been described. Therefore, this study aims to describe ECG parameters in BAV patients, and investigate their prognostic value.
Methods
In this single-center prospective study patients with BAV without a prior aortic valve replacement (AVR) were included. Transthoracic echocardiogram and 12‑lead resting-ECG were obtained. Associations between ECG parameters and the composite endpoint of all-cause mortality and AVR were assessed using Cox-proportional hazard analysis.
Results
120 patients with BAV were included (median age 30 years, 61% male). Median aortic jet velocity was 2.4 m/s [IQR: 1.7–3.4] and 5 patients (4%) had severe aortic regurgitation. All patients were in sinus rhythm. Any ECG abnormality was present in 57 patients (48%). Median PR-interval was 156 [IQR: 138–170] msec. A deviating QRS axis was found in 17 patients (14%) and Cornell criteria for LVH were fulfilled in 20 patients (17%). Repolarization abnormalities were present in 12 patients (10%). Median follow-up duration was 7.0 [6.3–9.8] years, during which 23 patients underwent AVR and 2 patients died. After adjusting for age, a longer PR-interval was associated with worse intervention-free survival (HR 1.02, 95% CI: 1.01–1.04).
Conclusion
Almost half of the patients with BAV had abnormalities on their ECG. Moreover, the PR-interval may be an interesting prognostic marker for intervention-free survival in BAV patients.
期刊介绍:
The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.