热压、铣削和 3D 打印二硅酸锂超薄咬合贴面的承载能力、内部精度和时间效率。

IF 4.6 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Dental Materials Pub Date : 2024-07-29 DOI:10.1016/j.dental.2024.07.017
Pune Nina Paqué , Cindy Gantner , Kiren Jan Mätzener , Mutlu Özcan , Alexis Ioannidis
{"title":"热压、铣削和 3D 打印二硅酸锂超薄咬合贴面的承载能力、内部精度和时间效率。","authors":"Pune Nina Paqué ,&nbsp;Cindy Gantner ,&nbsp;Kiren Jan Mätzener ,&nbsp;Mutlu Özcan ,&nbsp;Alexis Ioannidis","doi":"10.1016/j.dental.2024.07.017","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>The primary aim of this in vitro study was to compare the load-bearing capacity of lithium disilicate occlusal veneers, fabricated via different manufacturing processes. Secondary objectives included assessing internal accuracy and production time-efficiency.</p></div><div><h3>Methods</h3><p>Four fabrication methods for ultra-thin lithium disilicate occlusal veneers on extracted human molars with simulated erosive defects were compared (n = 20/group): CAM: milled lithium disilicate (IPS e.max CAD); HPR: heat-pressed lithium disilicate (IPS e.max Press) out of a milled PMMA template (Ddpmma CAST); 3DP: 3D-printed lithium disilicate (experimental lithium disilicate); PTE: heat-pressed lithium disilicate (IPS e.max Press) out of a 3D-printed template (SilaPrint cast). Internal accuracy was measured prior to thermo-mechanical aging, followed by static loading to measure the load-bearing capacity (F<sub>max</sub>). Fabrication time (time-efficiency) was also recorded. Statistical analysis was performed using the Kruskal-Wallis (KW) test.</p></div><div><h3>Results</h3><p>No statistically significant differences were found in median load-bearing capacities (F<sub>max</sub>) between the groups (KW p = 0.5902): CAM 1821 N, HPR 1896 N, 3DP 2003 N, PTE 1687 N. Significant differences were found in internal accuracy between the groups that employed printing processes (3DP, PTE) and all other groups in margins (p &lt; 0.001), cusps (p &lt; 0.0018), and fossae (p &lt; 0.0346). The time-efficiency measurements indicated an increase in fabrication time, starting from CAM 67.2 ± 5.8 min, followed by HPR 200.8 ± 33.0 min, PTE 289.2 ± 38.7 min, and peaking with the highest duration observed for 3DP 701.6 ± 8.1 min.</p></div><div><h3>Significance</h3><p>The fabrication method of ultra-thin lithium disilicate occlusal veneers does not significantly impact their load-bearing capacity, but affects the clinical fit and adaptation of the veneers.</p></div>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":"40 10","pages":"Pages 1602-1610"},"PeriodicalIF":4.6000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0109564124002070/pdfft?md5=d549af4f732ce30a8b602828f9e3f13a&pid=1-s2.0-S0109564124002070-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Load-bearing capacity, internal accuracy and time-efficiency of heat-pressed, milled and 3D-printed lithium disilicate ultra-thin occlusal veneers\",\"authors\":\"Pune Nina Paqué ,&nbsp;Cindy Gantner ,&nbsp;Kiren Jan Mätzener ,&nbsp;Mutlu Özcan ,&nbsp;Alexis Ioannidis\",\"doi\":\"10.1016/j.dental.2024.07.017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><p>The primary aim of this in vitro study was to compare the load-bearing capacity of lithium disilicate occlusal veneers, fabricated via different manufacturing processes. Secondary objectives included assessing internal accuracy and production time-efficiency.</p></div><div><h3>Methods</h3><p>Four fabrication methods for ultra-thin lithium disilicate occlusal veneers on extracted human molars with simulated erosive defects were compared (n = 20/group): CAM: milled lithium disilicate (IPS e.max CAD); HPR: heat-pressed lithium disilicate (IPS e.max Press) out of a milled PMMA template (Ddpmma CAST); 3DP: 3D-printed lithium disilicate (experimental lithium disilicate); PTE: heat-pressed lithium disilicate (IPS e.max Press) out of a 3D-printed template (SilaPrint cast). Internal accuracy was measured prior to thermo-mechanical aging, followed by static loading to measure the load-bearing capacity (F<sub>max</sub>). Fabrication time (time-efficiency) was also recorded. Statistical analysis was performed using the Kruskal-Wallis (KW) test.</p></div><div><h3>Results</h3><p>No statistically significant differences were found in median load-bearing capacities (F<sub>max</sub>) between the groups (KW p = 0.5902): CAM 1821 N, HPR 1896 N, 3DP 2003 N, PTE 1687 N. Significant differences were found in internal accuracy between the groups that employed printing processes (3DP, PTE) and all other groups in margins (p &lt; 0.001), cusps (p &lt; 0.0018), and fossae (p &lt; 0.0346). The time-efficiency measurements indicated an increase in fabrication time, starting from CAM 67.2 ± 5.8 min, followed by HPR 200.8 ± 33.0 min, PTE 289.2 ± 38.7 min, and peaking with the highest duration observed for 3DP 701.6 ± 8.1 min.</p></div><div><h3>Significance</h3><p>The fabrication method of ultra-thin lithium disilicate occlusal veneers does not significantly impact their load-bearing capacity, but affects the clinical fit and adaptation of the veneers.</p></div>\",\"PeriodicalId\":298,\"journal\":{\"name\":\"Dental Materials\",\"volume\":\"40 10\",\"pages\":\"Pages 1602-1610\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0109564124002070/pdfft?md5=d549af4f732ce30a8b602828f9e3f13a&pid=1-s2.0-S0109564124002070-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0109564124002070\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0109564124002070","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的这项体外研究的主要目的是比较通过不同生产工艺制作的二硅酸锂咬合贴面的承重能力。次要目标包括评估内部精度和生产时间效率:比较了四种超薄二硅酸锂咬合贴面的制作方法(n = 20/组):CAM:铣制二硅酸锂(IPS e.max CAD);HPR:热压二硅酸锂(IPS e.max Press),采用铣制的 PMMA 模板(Ddpmma CAST);3DP:3D 打印二硅酸锂(实验二硅酸锂);PTE:热压二硅酸锂(IPS e.max Press),采用 3D 打印模板(SilaPrint cast)。在热机械老化之前测量内部精度,然后进行静态加载以测量承载能力(Fmax)。同时还记录了制作时间(时间效率)。统计分析采用 Kruskal-Wallis (KW) 检验:结果:各组之间的中位承重能力(Fmax)没有明显的统计学差异(KW p = 0.5902):采用印刷工艺(3DP、PTE)的组与所有其他组在内部精度方面存在显著差异(p):超薄二硅酸锂咬合贴面的制作方法不会对其承重能力产生显著影响,但会影响贴面的临床密合性和适应性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Load-bearing capacity, internal accuracy and time-efficiency of heat-pressed, milled and 3D-printed lithium disilicate ultra-thin occlusal veneers

Objectives

The primary aim of this in vitro study was to compare the load-bearing capacity of lithium disilicate occlusal veneers, fabricated via different manufacturing processes. Secondary objectives included assessing internal accuracy and production time-efficiency.

Methods

Four fabrication methods for ultra-thin lithium disilicate occlusal veneers on extracted human molars with simulated erosive defects were compared (n = 20/group): CAM: milled lithium disilicate (IPS e.max CAD); HPR: heat-pressed lithium disilicate (IPS e.max Press) out of a milled PMMA template (Ddpmma CAST); 3DP: 3D-printed lithium disilicate (experimental lithium disilicate); PTE: heat-pressed lithium disilicate (IPS e.max Press) out of a 3D-printed template (SilaPrint cast). Internal accuracy was measured prior to thermo-mechanical aging, followed by static loading to measure the load-bearing capacity (Fmax). Fabrication time (time-efficiency) was also recorded. Statistical analysis was performed using the Kruskal-Wallis (KW) test.

Results

No statistically significant differences were found in median load-bearing capacities (Fmax) between the groups (KW p = 0.5902): CAM 1821 N, HPR 1896 N, 3DP 2003 N, PTE 1687 N. Significant differences were found in internal accuracy between the groups that employed printing processes (3DP, PTE) and all other groups in margins (p < 0.001), cusps (p < 0.0018), and fossae (p < 0.0346). The time-efficiency measurements indicated an increase in fabrication time, starting from CAM 67.2 ± 5.8 min, followed by HPR 200.8 ± 33.0 min, PTE 289.2 ± 38.7 min, and peaking with the highest duration observed for 3DP 701.6 ± 8.1 min.

Significance

The fabrication method of ultra-thin lithium disilicate occlusal veneers does not significantly impact their load-bearing capacity, but affects the clinical fit and adaptation of the veneers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dental Materials
Dental Materials 工程技术-材料科学:生物材料
CiteScore
9.80
自引率
10.00%
发文量
290
审稿时长
67 days
期刊介绍: Dental Materials publishes original research, review articles, and short communications. Academy of Dental Materials members click here to register for free access to Dental Materials online. The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology. Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.
期刊最新文献
Bonding neat hydrophobic-rich resins to etched dentin: A proof of concept. Models for shrinkage stress: C-factor and all that. Ability of a novel primer to enhance the polymerization of a self-cured resin composite. Classification and bibliometric analysis of hydrogels in periodontitis treatment: Trends, mechanisms, advantages, and future research directions. Microspheres of stem cells from human exfoliated deciduous teeth exhibit superior pulp regeneration capacity.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1