Zongwang Zhai, Yanjiang Wang, Liang Shi, Xingpeng Liu
{"title":"脉冲电场消融对其束传导的影响:犬临床前研究","authors":"Zongwang Zhai, Yanjiang Wang, Liang Shi, Xingpeng Liu","doi":"10.12659/MSM.945007","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND Pulsed field ablation (PFA), as a non-thermal ablation modality, has received increasing attention. The aim of this study was to evaluate the effect of PFA upon His bundle via its implementation with different voltages on the maximum His bundle potential in canines, providing scientific basis for clinical application. MATERIAL AND METHODS Pulsed electrical field energy was delivered from a ablation catheter to the maximum His potential of 7 dogs, followed by a series of electrogram and histology assessments. RESULTS The baseline AH and HV intervals were 55.3±3.7 ms (range, 53.0-59.0 ms), and 34.9±1.3 ms (range, 34.0-36.0 ms), respectively, which were elevated to 65.0±5.4 ms (range, 59.0-70.0 ms) and 35.7±2.7 ms (range, 34.0-37.0 ms) after PFA. Before ablation and immediately after the recovery of third-degree AVB, the AH interval was prolonged (P<0.05) while the HV interval remained unchanged (P>0.05). After ablation, all 7 canines experienced transient third-degree AVB, with a voltage-dependent duration. Masson staining results revealed no apparent damage in His bundle cells. CONCLUSIONS Within a certain voltage range of pulse electric field, ablation of the maximum His potential in canines can result in transient third-degree AVB, providing a new route for guiding safe ablation of para-Hisian arrhythmia.</p>","PeriodicalId":48888,"journal":{"name":"Medical Science Monitor","volume":"30 ","pages":"e945007"},"PeriodicalIF":3.1000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11297367/pdf/","citationCount":"0","resultStr":"{\"title\":\"Impact of Pulsed Electric Field Ablation on His Bundle Conduction: A Preclinical Canine Study.\",\"authors\":\"Zongwang Zhai, Yanjiang Wang, Liang Shi, Xingpeng Liu\",\"doi\":\"10.12659/MSM.945007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BACKGROUND Pulsed field ablation (PFA), as a non-thermal ablation modality, has received increasing attention. The aim of this study was to evaluate the effect of PFA upon His bundle via its implementation with different voltages on the maximum His bundle potential in canines, providing scientific basis for clinical application. MATERIAL AND METHODS Pulsed electrical field energy was delivered from a ablation catheter to the maximum His potential of 7 dogs, followed by a series of electrogram and histology assessments. RESULTS The baseline AH and HV intervals were 55.3±3.7 ms (range, 53.0-59.0 ms), and 34.9±1.3 ms (range, 34.0-36.0 ms), respectively, which were elevated to 65.0±5.4 ms (range, 59.0-70.0 ms) and 35.7±2.7 ms (range, 34.0-37.0 ms) after PFA. Before ablation and immediately after the recovery of third-degree AVB, the AH interval was prolonged (P<0.05) while the HV interval remained unchanged (P>0.05). After ablation, all 7 canines experienced transient third-degree AVB, with a voltage-dependent duration. Masson staining results revealed no apparent damage in His bundle cells. CONCLUSIONS Within a certain voltage range of pulse electric field, ablation of the maximum His potential in canines can result in transient third-degree AVB, providing a new route for guiding safe ablation of para-Hisian arrhythmia.</p>\",\"PeriodicalId\":48888,\"journal\":{\"name\":\"Medical Science Monitor\",\"volume\":\"30 \",\"pages\":\"e945007\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11297367/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Science Monitor\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.12659/MSM.945007\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Science Monitor","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12659/MSM.945007","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
背景脉冲场消融(PFA)作为一种非热消融方式,已受到越来越多的关注。本研究旨在评估 PFA 通过不同电压对犬 His 束最大电位的影响,为临床应用提供科学依据。材料和方法 从消融导管向 7 只犬的最大 His 电位输送脉冲电场能量,然后进行一系列电图和组织学评估。结果 基线 AH 和 HV 间期分别为 55.3±3.7毫秒(范围:53.0-59.0 毫秒)和 34.9±1.3毫秒(范围:34.0-36.0 毫秒),PFA 后分别升至 65.0±5.4毫秒(范围:59.0-70.0 毫秒)和 35.7±2.7毫秒(范围:34.0-37.0 毫秒)。消融前和三度 AVB 恢复后,AH 间期立即延长(P0.05)。消融后,所有 7 只犬都出现了短暂的三度房室传导阻滞,其持续时间与电压有关。Masson 染色结果显示 His 束细胞无明显损伤。结论 在一定的脉冲电场电压范围内,消融犬的最大 His 电位可导致短暂的三度房室传导阻滞,为指导安全消融副 His 体心律失常提供了一条新途径。
Impact of Pulsed Electric Field Ablation on His Bundle Conduction: A Preclinical Canine Study.
BACKGROUND Pulsed field ablation (PFA), as a non-thermal ablation modality, has received increasing attention. The aim of this study was to evaluate the effect of PFA upon His bundle via its implementation with different voltages on the maximum His bundle potential in canines, providing scientific basis for clinical application. MATERIAL AND METHODS Pulsed electrical field energy was delivered from a ablation catheter to the maximum His potential of 7 dogs, followed by a series of electrogram and histology assessments. RESULTS The baseline AH and HV intervals were 55.3±3.7 ms (range, 53.0-59.0 ms), and 34.9±1.3 ms (range, 34.0-36.0 ms), respectively, which were elevated to 65.0±5.4 ms (range, 59.0-70.0 ms) and 35.7±2.7 ms (range, 34.0-37.0 ms) after PFA. Before ablation and immediately after the recovery of third-degree AVB, the AH interval was prolonged (P<0.05) while the HV interval remained unchanged (P>0.05). After ablation, all 7 canines experienced transient third-degree AVB, with a voltage-dependent duration. Masson staining results revealed no apparent damage in His bundle cells. CONCLUSIONS Within a certain voltage range of pulse electric field, ablation of the maximum His potential in canines can result in transient third-degree AVB, providing a new route for guiding safe ablation of para-Hisian arrhythmia.
期刊介绍:
Medical Science Monitor (MSM) established in 1995 is an international, peer-reviewed scientific journal which publishes original articles in Clinical Medicine and related disciplines such as Epidemiology and Population Studies, Product Investigations, Development of Laboratory Techniques :: Diagnostics and Medical Technology which enable presentation of research or review works in overlapping areas of medicine and technology such us (but not limited to): medical diagnostics, medical imaging systems, computer simulation of health and disease processes, new medical devices, etc. Reviews and Special Reports - papers may be accepted on the basis that they provide a systematic, critical and up-to-date overview of literature pertaining to research or clinical topics. Meta-analyses are considered as reviews. A special attention will be paid to a teaching value of a review paper.
Medical Science Monitor is internationally indexed in Thomson-Reuters Web of Science, Journals Citation Report (JCR), Science Citation Index Expanded (SCI), Index Medicus MEDLINE, PubMed, PMC, EMBASE/Excerpta Medica, Chemical Abstracts CAS and Index Copernicus.