用于锗探测器读出的低噪声、低背景电荷敏感放大器的设计与特性分析

IF 1.9 3区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Transactions on Nuclear Science Pub Date : 2024-07-29 DOI:10.1109/TNS.2024.3434345
D. Butta;G. Borghi;M. Carminati;G. Ferrari;A. Gieb;F. Henkes;M. Willers;S. Mertens;S. Riboldi;C. Fiorini
{"title":"用于锗探测器读出的低噪声、低背景电荷敏感放大器的设计与特性分析","authors":"D. Butta;G. Borghi;M. Carminati;G. Ferrari;A. Gieb;F. Henkes;M. Willers;S. Mertens;S. Riboldi;C. Fiorini","doi":"10.1109/TNS.2024.3434345","DOIUrl":null,"url":null,"abstract":"The large enriched germanium experiment for neutrinoless double beta decay (LEGEND) is a ton-scale experimental program to search for neutrinoless double beta (\n<inline-formula> <tex-math>$0\\nu \\beta \\beta $ </tex-math></inline-formula>\n) decay in the isotope \n<inline-formula> <tex-math>$^{76}\\textrm {Ge}$ </tex-math></inline-formula>\n by means of high-purity germanium (HPGe) detectors operated in liquid argon (LAr). The observation of \n<inline-formula> <tex-math>$0\\nu \\beta \\beta $ </tex-math></inline-formula>\n decay would have major implications in the understanding of the origin of the matter in the universe and establish neutrinos as Majorana particles, i.e., their own antiparticles. In this framework, the LEGEND ultralow background integrated circuit for germanium detectors investigation (LUIGI) application-specific integrated circuit (ASIC) was designed. The ASIC technology enables the implementation of the whole charge sensitive amplifier (CSA) into a single low-mass chip. The LUIGI ASIC can play a key role to obtain good energy resolution (at 2039 keV, i.e., the \n<inline-formula> <tex-math>$Q_{\\beta \\beta }$ </tex-math></inline-formula>\n value of the \n<inline-formula> <tex-math>$^{76}\\textrm {Ge} \\; \\beta \\beta $ </tex-math></inline-formula>\n-decay, a value of \n<inline-formula> <tex-math>$2.49 \\; \\pm \\; 0.03\\,\\text {keV}$ </tex-math></inline-formula>\n full-width at half-maximum (FWHM) is obtained) and a high radiopurity which are the main requirements for the readout electronics in \n<inline-formula> <tex-math>$0\\nu \\beta \\beta $ </tex-math></inline-formula>\n decay experiments. It was designed featuring a low-noise CSA and an ON-chip low-dropout (LDO) regulator. (At a shaping time of \n<inline-formula> <tex-math>$6\\,\\mu $ </tex-math></inline-formula>\ns, an energy resolution at the noise peak of 500 eV FWHM is measured.) Two different versions of the CSA were implemented. The LUIGI-internal reset (IR) variant has a dedicated compensation network and implements an integrated large-value resistor through an ICON cell. Instead, the LUIGI-feedback resistor (RF) variant works with a large value external RF. The LDO makes it possible to power the chip without bypass capacitors, which are not compliant with the radiopurity requirement. A dedicated line driver circuit drives the signal in a differential way over a distance of about 10 m.","PeriodicalId":13406,"journal":{"name":"IEEE Transactions on Nuclear Science","volume":"71 9","pages":"2171-2179"},"PeriodicalIF":1.9000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10613781","citationCount":"0","resultStr":"{\"title\":\"Design and Characterization of a Low-Noise and Low-Background Charge Sensitive Amplifier for the Readout of Germanium Detectors\",\"authors\":\"D. Butta;G. Borghi;M. Carminati;G. Ferrari;A. Gieb;F. Henkes;M. Willers;S. Mertens;S. Riboldi;C. Fiorini\",\"doi\":\"10.1109/TNS.2024.3434345\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The large enriched germanium experiment for neutrinoless double beta decay (LEGEND) is a ton-scale experimental program to search for neutrinoless double beta (\\n<inline-formula> <tex-math>$0\\\\nu \\\\beta \\\\beta $ </tex-math></inline-formula>\\n) decay in the isotope \\n<inline-formula> <tex-math>$^{76}\\\\textrm {Ge}$ </tex-math></inline-formula>\\n by means of high-purity germanium (HPGe) detectors operated in liquid argon (LAr). The observation of \\n<inline-formula> <tex-math>$0\\\\nu \\\\beta \\\\beta $ </tex-math></inline-formula>\\n decay would have major implications in the understanding of the origin of the matter in the universe and establish neutrinos as Majorana particles, i.e., their own antiparticles. In this framework, the LEGEND ultralow background integrated circuit for germanium detectors investigation (LUIGI) application-specific integrated circuit (ASIC) was designed. The ASIC technology enables the implementation of the whole charge sensitive amplifier (CSA) into a single low-mass chip. The LUIGI ASIC can play a key role to obtain good energy resolution (at 2039 keV, i.e., the \\n<inline-formula> <tex-math>$Q_{\\\\beta \\\\beta }$ </tex-math></inline-formula>\\n value of the \\n<inline-formula> <tex-math>$^{76}\\\\textrm {Ge} \\\\; \\\\beta \\\\beta $ </tex-math></inline-formula>\\n-decay, a value of \\n<inline-formula> <tex-math>$2.49 \\\\; \\\\pm \\\\; 0.03\\\\,\\\\text {keV}$ </tex-math></inline-formula>\\n full-width at half-maximum (FWHM) is obtained) and a high radiopurity which are the main requirements for the readout electronics in \\n<inline-formula> <tex-math>$0\\\\nu \\\\beta \\\\beta $ </tex-math></inline-formula>\\n decay experiments. It was designed featuring a low-noise CSA and an ON-chip low-dropout (LDO) regulator. (At a shaping time of \\n<inline-formula> <tex-math>$6\\\\,\\\\mu $ </tex-math></inline-formula>\\ns, an energy resolution at the noise peak of 500 eV FWHM is measured.) Two different versions of the CSA were implemented. The LUIGI-internal reset (IR) variant has a dedicated compensation network and implements an integrated large-value resistor through an ICON cell. Instead, the LUIGI-feedback resistor (RF) variant works with a large value external RF. The LDO makes it possible to power the chip without bypass capacitors, which are not compliant with the radiopurity requirement. A dedicated line driver circuit drives the signal in a differential way over a distance of about 10 m.\",\"PeriodicalId\":13406,\"journal\":{\"name\":\"IEEE Transactions on Nuclear Science\",\"volume\":\"71 9\",\"pages\":\"2171-2179\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10613781\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Nuclear Science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10613781/\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Nuclear Science","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10613781/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

无中微子双贝塔衰变大型富集锗实验(LEGEND)是一项吨级实验计划,目的是通过在液态氩(LAr)中运行的高纯锗(HPGe)探测器来寻找同位素$^{76}\textrm {Ge}$中的无中微子双贝塔($0\nu \beta \beta $)衰变。对$0\nu \beta \beta $衰变的观测将对理解宇宙物质的起源产生重大影响,并确定中微子为马约拉纳粒子,即其自身的反粒子。在此框架下,设计了用于锗探测器研究的 LEGEND 超低本底集成电路(LUIGI)专用集成电路(ASIC)。ASIC 技术可将整个电荷敏感放大器(CSA)集成到一个低质量芯片中。LUIGI ASIC在获得良好的能量分辨率(2039 keV,即$^{76}\textrm {Ge} 的$Q_{\beta \beta }$ 值)方面发挥了关键作用。\beta \beta $ -decay,获得了$2.49 \; \pm \; 0.03\, \text {keV}$的半最大全宽(FWHM))和高辐射纯度,这是在$0\nu \beta \beta $衰变实验中对读出电子设备的主要要求。它的设计特点是采用低噪声 CSA 和片上低压差(LDO)稳压器。(在6,\mu $ s的整形时间内,测得噪声峰值的能量分辨率为500 eV FWHM)。CSA 有两个不同的版本。LUIGI-内部复位(IR)变体有一个专用补偿网络,并通过一个 ICON 单元实现了一个集成大值电阻器。相反,LUIGI-反馈电阻器(RF)变体则采用大值外部 RF。LDO 使芯片无需旁路电容器供电成为可能,因为旁路电容器不符合防辐射要求。专用线路驱动电路以差分方式驱动信号,传输距离约为 10 米。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and Characterization of a Low-Noise and Low-Background Charge Sensitive Amplifier for the Readout of Germanium Detectors
The large enriched germanium experiment for neutrinoless double beta decay (LEGEND) is a ton-scale experimental program to search for neutrinoless double beta ( $0\nu \beta \beta $ ) decay in the isotope $^{76}\textrm {Ge}$ by means of high-purity germanium (HPGe) detectors operated in liquid argon (LAr). The observation of $0\nu \beta \beta $ decay would have major implications in the understanding of the origin of the matter in the universe and establish neutrinos as Majorana particles, i.e., their own antiparticles. In this framework, the LEGEND ultralow background integrated circuit for germanium detectors investigation (LUIGI) application-specific integrated circuit (ASIC) was designed. The ASIC technology enables the implementation of the whole charge sensitive amplifier (CSA) into a single low-mass chip. The LUIGI ASIC can play a key role to obtain good energy resolution (at 2039 keV, i.e., the $Q_{\beta \beta }$ value of the $^{76}\textrm {Ge} \; \beta \beta $ -decay, a value of $2.49 \; \pm \; 0.03\,\text {keV}$ full-width at half-maximum (FWHM) is obtained) and a high radiopurity which are the main requirements for the readout electronics in $0\nu \beta \beta $ decay experiments. It was designed featuring a low-noise CSA and an ON-chip low-dropout (LDO) regulator. (At a shaping time of $6\,\mu $ s, an energy resolution at the noise peak of 500 eV FWHM is measured.) Two different versions of the CSA were implemented. The LUIGI-internal reset (IR) variant has a dedicated compensation network and implements an integrated large-value resistor through an ICON cell. Instead, the LUIGI-feedback resistor (RF) variant works with a large value external RF. The LDO makes it possible to power the chip without bypass capacitors, which are not compliant with the radiopurity requirement. A dedicated line driver circuit drives the signal in a differential way over a distance of about 10 m.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Nuclear Science
IEEE Transactions on Nuclear Science 工程技术-工程:电子与电气
CiteScore
3.70
自引率
27.80%
发文量
314
审稿时长
6.2 months
期刊介绍: The IEEE Transactions on Nuclear Science is a publication of the IEEE Nuclear and Plasma Sciences Society. It is viewed as the primary source of technical information in many of the areas it covers. As judged by JCR impact factor, TNS consistently ranks in the top five journals in the category of Nuclear Science & Technology. It has one of the higher immediacy indices, indicating that the information it publishes is viewed as timely, and has a relatively long citation half-life, indicating that the published information also is viewed as valuable for a number of years. The IEEE Transactions on Nuclear Science is published bimonthly. Its scope includes all aspects of the theory and application of nuclear science and engineering. It focuses on instrumentation for the detection and measurement of ionizing radiation; particle accelerators and their controls; nuclear medicine and its application; effects of radiation on materials, components, and systems; reactor instrumentation and controls; and measurement of radiation in space.
期刊最新文献
Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society Table of Contents IEEE Transactions on Nuclear Science publication information IEEE Transactions on Nuclear Science information for authors TechRxiv: Share Your Preprint Research with the World!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1